{"created":"2021-03-01T06:12:45.469896+00:00","id":6159,"links":{},"metadata":{"_buckets":{"deposit":"f97bc45b-4ce0-4f90-81d7-77319444dd4f"},"_deposit":{"id":"6159","owners":[],"pid":{"revision_id":0,"type":"depid","value":"6159"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00006159"},"item_10_biblio_info_6":{"attribute_name":"\u66f8\u8a8c\u60c5\u5831","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-03","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{"bibliographic_title":"2006 IEEE International sysposium on Power Line Communications and its Applications"}]}]},"item_10_description_4":{"attribute_name":"\u6284\u9332","attribute_value_mlt":[{"subitem_description":"This manuscript discusses the relationships of noise waveforms measured at different outlets in a three-wire single-phase (one neutral and two live conductors) power-line network. As a result of experimental measurements, it is confirmed that instantaneous noise voltages at two different outlets have high correlations if the outlets are connected the same live conductor in a distribution board, while the outlets for the different live conductors provide noise waveforms with low correlations. It is also shown that the instantaneous noise powers and cyclic averaged noise powers as time functions have large correlations even at a pair of outlets connected to the different live conductors. The correlation coefficients for instantaneous voltages and powers are also calculated as the frequency functions.","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/7797"}]},"item_10_publisher_32":{"attribute_name":"\u51fa\u7248\u8005","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1109/ISPLC.2006.247443","subitem_relation_type_select":"DOI"}}]},"item_10_relation_8":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"1-4244-0113-5","subitem_relation_type_select":"ISBN"}}]},"item_10_rights_12":{"attribute_name":"\u6a29\u5229","attribute_value_mlt":[{"subitem_rights":"Copyright \u00a9 2006 IEEE. Reprinted from 2006 IEEE International sysposium on Power Line Communications and its Applications. 2006. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University\u2019s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org."}]},"item_10_select_15":{"attribute_name":"\u8457\u8005\u7248\u30d5\u30e9\u30b0","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_text_14":{"attribute_name":"\u30d5\u30a9\u30fc\u30de\u30c3\u30c8","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_creator":{"attribute_name":"\u8457\u8005","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kawaguchi, Akio"}],"nameIdentifiers":[{"nameIdentifier":"16619","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okada, Hiraku"}],"nameIdentifiers":[{"nameIdentifier":"16620","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamazato, Takaya"}],"nameIdentifiers":[{"nameIdentifier":"16621","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katayama, Masaaki"}],"nameIdentifiers":[{"nameIdentifier":"16622","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"\u30d5\u30a1\u30a4\u30eb\u60c5\u5831","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"isplc-3.pdf","filesize":[{"value":"842.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"isplc-3.pdf","url":"https://nagoya.repo.nii.ac.jp/record/6159/files/isplc-3.pdf"},"version_id":"fbc26f74-d57e-4304-b854-55c909936c86"}]},"item_language":{"attribute_name":"\u8a00\u8a9e","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"\u8cc7\u6e90\u30bf\u30a4\u30d7","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Correlations of noise wavements at different outlets in a power-line network","item_titles":{"attribute_name":"\u30bf\u30a4\u30c8\u30eb","attribute_value_mlt":[{"subitem_title":"Correlations of noise wavements at different outlets in a power-line network"}]},"item_type_id":"10","owner":"1","path":["320/502/503"],"pubdate":{"attribute_name":"\u516c\u958b\u65e5","attribute_value":"2007-05-16"},"publish_date":"2007-05-16","publish_status":"0","recid":"6159","relation_version_is_last":true,"title":["Correlations of noise wavements at different outlets in a power-line network"],"weko_creator_id":"1","weko_shared_id":3},"updated":"2021-03-01T11:52:22.932700+00:00"}