{"created":"2021-03-01T06:14:00.333438+00:00","id":7351,"links":{},"metadata":{"_buckets":{"deposit":"da1d0056-8274-41e3-a935-043fdc5f8868"},"_deposit":{"id":"7351","owners":[],"pid":{"revision_id":0,"type":"depid","value":"7351"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00007351","sets":["320:321:322"]},"author_link":["20371","20372","20373","20374","20375","20376","20377","20378"],"item_10_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Functionally Graded Plasma Spraying of Bio-Ceramics on Model Material of Implant","subitem_alternative_title_language":"en"}]},"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"660","bibliographicPageEnd":"2691","bibliographicPageStart":"2686","bibliographicVolumeNumber":"67","bibliographic_titles":[{"bibliographic_title":"日本機械学會論文集 C編","bibliographic_titleLang":"ja"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The necessity to substitute the artificial part so called medical implant for broken or worn bone is growing as old people increase. Materials for implant should have both the same mechanical properties as original tissues and biocompatibility. However, it is difficult that a single material satisfies these requirements simultaneously. In this study, a hybrid implant material which was composed of surface material and substantial material was developed by plasma spraying technique. Powders of hydroxyapatite (HAp) and titanium were sprayed on the titanium substrate in such way that the composition of HAp was increased gradually toward the surface. The performance of obtained HAp coatings was investigated with SEM observation, X-ray diffraction, adherence test, friction test and dissolution test. It was found that hardness, adhension strength and corrosion resistance were improved with increase in plasma energy and that they were much improved by YAG laser irradiation after spraying. However, sprayed coatings were inferior in hardness and corrosion resistance to the pig bone or sintered HAp because of porous structure. Therefore to produce medical implants by this method, biomimetic designing will be necessary.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/9032"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会","subitem_publisher_language":"ja"}]},"item_10_relation_43":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110002386342/","subitem_relation_type_select":"URI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本機械学会","subitem_rights_language":"ja"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである。","subitem_rights_language":"ja"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5024","subitem_source_identifier_type":"PISSN"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"森, 敏彦","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20371","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"MORI, Toshihiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20372","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"広田, 健治","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20373","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"HIROTA, Kenji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20374","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小林, 鑑明","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20375","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KOBAYASHI, Kanmei","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20376","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"助田, 直史","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20377","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"SUKEDA, Naofumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20378","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"JsMecEngC_67-660-2686.pdf","filesize":[{"value":"706.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"JsMecEngC_67-660-2686.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/7351/files/JsMecEngC_67-660-2686.pdf"},"version_id":"febdbfb0-3d89-4693-9f50-1307e74c5729"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Spraying","subitem_subject_scheme":"Other"},{"subitem_subject":"Coating","subitem_subject_scheme":"Other"},{"subitem_subject":"Surface Treatment","subitem_subject_scheme":"Other"},{"subitem_subject":"Functionally Gradient Material","subitem_subject_scheme":"Other"},{"subitem_subject":"Friction","subitem_subject_scheme":"Other"},{"subitem_subject":"Implant","subitem_subject_scheme":"Other"},{"subitem_subject":"Bioceramics","subitem_subject_scheme":"Other"},{"subitem_subject":"Titanium","subitem_subject_scheme":"Other"},{"subitem_subject":"Hydroxyapatite","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"インプラントモデル材へのバイオセラミックスの傾斜機能溶射","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"インプラントモデル材へのバイオセラミックスの傾斜機能溶射","subitem_title_language":"ja"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-11-21"},"publish_date":"2007-11-21","publish_status":"0","recid":"7351","relation_version_is_last":true,"title":["インプラントモデル材へのバイオセラミックスの傾斜機能溶射"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:52:53.647374+00:00"}