{"created":"2021-03-01T06:14:04.082707+00:00","id":7411,"links":{},"metadata":{"_buckets":{"deposit":"b3c3f25a-9737-410a-b7ac-53fa3c857737"},"_deposit":{"id":"7411","owners":[],"pid":{"revision_id":0,"type":"depid","value":"7411"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00007411","sets":["320:321:322"]},"author_link":["20643","20644","20645","20646","20647","20648","20649","20650","20651","20652","20653","20654","20655","20656"],"item_10_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Operation of Air-conditioning Machine with an Additional Condenser","subitem_alternative_title_language":"en"}]},"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"716","bibliographicPageEnd":"1102","bibliographicPageStart":"1095","bibliographicVolumeNumber":"72","bibliographic_titles":[{"bibliographic_title":"日本機械学會論文集 B編","bibliographic_titleLang":"ja"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"By installing an additional condenser on the air-conditioning machine designed for HCFC22, a more efficient heat pump system could be operated with HFC134a as well as HCFC22 without changing mineral lubricant oil. It was shown that COP for cooling operation was improved when operating with HCFC22 and HFC134a. It was also shown that this heat pump system could be operated at higher ambient temperature exceeding 50℃ when operating with HFC134a.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/9092"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会","subitem_publisher_language":"ja"}]},"item_10_relation_43":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110004718573/","subitem_relation_type_select":"URI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本機械学会","subitem_rights_language":"ja"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである。","subitem_rights_language":"ja"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5016","subitem_source_identifier_type":"PISSN"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"後藤, 誠","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20643","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"GOTO, Makoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20644","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷藤, 浩二","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20645","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"TANIFUJI, Koji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20646","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤田, 真弘","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20647","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"FUJITA, Masahiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20648","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山内, 智裕","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20649","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"YAMAUCHI, Tomohiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20650","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永田, 謙二","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20651","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"NAGATA, Kenji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20652","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"上野, 勲","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20653","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"UENO, Isao","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20654","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川, 達也","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"20655","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"HASEGAWA, Tatsuya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"20656","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"JsMecEngB_72-716-1095.pdf","filesize":[{"value":"671.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"JsMecEngB_72-716-1095.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/7411/files/JsMecEngB_72-716-1095.pdf"},"version_id":"b65a931b-d220-4330-bd29-25736161aa61"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Heat Pump","subitem_subject_scheme":"Other"},{"subitem_subject":"Additional Condenser","subitem_subject_scheme":"Other"},{"subitem_subject":"Mineral Oil","subitem_subject_scheme":"Other"},{"subitem_subject":"HCFC22","subitem_subject_scheme":"Other"},{"subitem_subject":"HFC134a","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"追設凝縮器を用いた空調機の運転","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"追設凝縮器を用いた空調機の運転","subitem_title_language":"ja"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-12-05"},"publish_date":"2007-12-05","publish_status":"0","recid":"7411","relation_version_is_last":true,"title":["追設凝縮器を用いた空調機の運転"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:52:44.523267+00:00"}