{"created":"2021-03-01T06:14:22.849710+00:00","id":7708,"links":{},"metadata":{"_buckets":{"deposit":"679aef5d-d3a2-4809-b5cf-91bc7d26f85c"},"_deposit":{"id":"7708","owners":[],"pid":{"revision_id":0,"type":"depid","value":"7708"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00007708","sets":["320:321:322"]},"author_link":["21852","21853"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"195","bibliographicPageStart":"192","bibliographic_titles":[{"bibliographic_title":"IEEE International Conference on Solid Dielectrics","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Life-cycle management based on the degradation diagnosis is useful for preventing an unexpected failure and extending service life of electric power apparatuses, minimizing life-cycle cost. In our previous study, we formulated a numerical model of life-cycle management based on time-based maintenance and condition-based maintenance. Then, we applied the model for evaluating the economic effect of degradation diagnosis of power cables, assuming that the maximum length of water tree as a replacement criterion can be measured nondestructively. To carry out reliable life cycle management, however, accurate data on the relation between extent of degradation and failure probability or remaining life are necessary. In this study, we examine the influence of accuracy of the data used to determine the optimum diagnostic parameters and evaluate how the life-cycle cost is affected by the employment of inaccurate data. The results show that the condition-based maintenance with degradation diagnosis can be less subject to the accuracy of the back data and is possible to realize the reliable life-cycle management.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/9426"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/ICSD.2007.4290785","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2007 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kato, T.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"21852","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suzuoki, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"21853","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"katoh.pdf","filesize":[{"value":"490.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"katoh.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/7708/files/katoh.pdf"},"version_id":"c9f78cf4-b66c-4b2c-a4fa-b2a527669669"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Robustness Assessment of Life-Cycle-Management of CV Cables based on Degradation Diagnosis","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Robustness Assessment of Life-Cycle-Management of CV Cables based on Degradation Diagnosis","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-02-20"},"publish_date":"2008-02-20","publish_status":"0","recid":"7708","relation_version_is_last":true,"title":["Robustness Assessment of Life-Cycle-Management of CV Cables based on Degradation Diagnosis"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:53:12.437078+00:00"}