{"_buckets": {"deposit": "9241bcfd-fd94-4f8a-85a8-4d2857f1f710"}, "_deposit": {"id": "7755", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "7755"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00007755", "sets": ["322"]}, "author_link": ["22001", "22002", "22003", "22004"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "1326", "bibliographicPageStart": "1320", "bibliographic_titles": [{"bibliographic_title": "Power Conversion Conference", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "For high performance and wide speed range control of an IPMSM, using the overmodulation range of an inverter is one of the effective methods. However, to use this overmodulation range with the closed loop currents control system, there are many problems occur and the main problem is caused by the harmonic currents generated from harmonic voltages in the inverter output voltages. Therefore, in the usual control methods of an IPMSM in the overmodulation range, these problems are avoided by not using the closed loop currents control or by using the closed loop currents control with the filters in the feedback part. With these methods, the problems from harmonic currents can be solved, but the other new problems also occur too. The method of harmonic currents compensation is also proposed and this method seems to be more effective than the others. However, in this method, the proposed harmonic currents estimation method is quite difficult in practical use, because the real value of the inverter output voltages are used, then the carrier frequency components will cause an aliasing problem in the estimation part and this problem will become more serious when the carrier frequency is high. To solve the above problem, in this paper, we propose the harmonic currents estimation and compensation method based on the inverter harmonic voltages model. In our proposed method, we use only the inverter commanded voltages in the harmonic voltages estimation, then this method is more easy for the practical use. Moreover, by using the inverter harmonic voltages model, the data of both amplitude and phase angle of harmonic voltages are available, then we can estimate the harmonic currents by using only simple phasor method compared with the complex dynamic model method in the former. The experimental results are shown to confirm our proposed estimation and compensation methods.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/9474"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/PCCON.2007.373136", "subitem_relation_type_select": "DOI"}}]}, "item_10_relation_8": {"attribute_name": "ISBN", "attribute_value_mlt": [{"subitem_relation_type": "isPartOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "1-4244-0844-X", "subitem_relation_type_select": "ISBN"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 2007 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Smith, Lerdudomsak", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "22001", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kadota, Mitsuhiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "22002", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Doki, Shinji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "22003", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okuma, Shigeru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "22004", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "doki_3.pdf", "filesize": [{"value": "549.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 549100.0, "url": {"label": "doki_3.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/7755/files/doki_3.pdf"}, "version_id": "5fc789a2-b231-48c5-9f2c-40f544127791"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "IPMSM", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Overmodulation range", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Current control", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Harmonic compensation", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Harmonic Currents Estimation and Compensation Method for Current Control System of IPMSM in Overmodulation Range", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Harmonic Currents Estimation and Compensation Method for Current Control System of IPMSM in Overmodulation Range", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/9474", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2008-02-26"}, "publish_date": "2008-02-26", "publish_status": "0", "recid": "7755", "relation": {}, "relation_version_is_last": true, "title": ["Harmonic Currents Estimation and Compensation Method for Current Control System of IPMSM in Overmodulation Range"], "weko_shared_id": -1}
Harmonic Currents Estimation and Compensation Method for Current Control System of IPMSM in Overmodulation Range
http://hdl.handle.net/2237/9474
http://hdl.handle.net/2237/947494c68367-cfa2-4f30-ab90-4e9e5b42f2c7
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-02-26 | |||||
タイトル | ||||||
タイトル | Harmonic Currents Estimation and Compensation Method for Current Control System of IPMSM in Overmodulation Range | |||||
言語 | en | |||||
著者 |
Smith, Lerdudomsak
× Smith, Lerdudomsak× Kadota, Mitsuhiro× Doki, Shinji× Okuma, Shigeru |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | Copyright © 2007 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org. | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | IPMSM | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Overmodulation range | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Current control | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Harmonic compensation | |||||
抄録 | ||||||
内容記述 | For high performance and wide speed range control of an IPMSM, using the overmodulation range of an inverter is one of the effective methods. However, to use this overmodulation range with the closed loop currents control system, there are many problems occur and the main problem is caused by the harmonic currents generated from harmonic voltages in the inverter output voltages. Therefore, in the usual control methods of an IPMSM in the overmodulation range, these problems are avoided by not using the closed loop currents control or by using the closed loop currents control with the filters in the feedback part. With these methods, the problems from harmonic currents can be solved, but the other new problems also occur too. The method of harmonic currents compensation is also proposed and this method seems to be more effective than the others. However, in this method, the proposed harmonic currents estimation method is quite difficult in practical use, because the real value of the inverter output voltages are used, then the carrier frequency components will cause an aliasing problem in the estimation part and this problem will become more serious when the carrier frequency is high. To solve the above problem, in this paper, we propose the harmonic currents estimation and compensation method based on the inverter harmonic voltages model. In our proposed method, we use only the inverter commanded voltages in the harmonic voltages estimation, then this method is more easy for the practical use. Moreover, by using the inverter harmonic voltages model, the data of both amplitude and phase angle of harmonic voltages are available, then we can estimate the harmonic currents by using only simple phasor method compared with the complex dynamic model method in the former. The experimental results are shown to confirm our proposed estimation and compensation methods. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | IEEE | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/PCCON.2007.373136 | |||||
ISBN | ||||||
関連タイプ | isPartOf | |||||
識別子タイプ | ISBN | |||||
関連識別子 | 1-4244-0844-X | |||||
書誌情報 |
en : Power Conversion Conference p. 1320-1326, 発行日 2007 |
|||||
フォーマット | ||||||
application/pdf | ||||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/9474 | |||||
識別子タイプ | HDL |