@article{oai:nagoya.repo.nii.ac.jp:00007784, author = {Ohka, Masahiro and Kobayashi, Hiroaki and Takata, Jumpei and Mitsuya, Yasunaga}, journal = {The 15th IEEE International Symposium on Robot and Human Interactive Communication}, month = {}, note = {We are developing an optical three-axis tactile sensor capable of acquiring normal and shearing force, with the aim of mounting it on a robotic finger. The tactile sensor is based on the principle of an optical waveguide-type tactile sensor, which is composed of an acrylic hemispherical dome, a light source, an array of rubber sensing elements, and a CCD camera. The sensing element of silicone rubber comprises one columnar feeler and eight conical feelers. The contact areas of the conical feelers, which maintain contact with the acrylic dome, detect the three-axis force applied to the tip of the sensing element. Normal and shearing forces are then calculated from integration and centroid displacement of the gray-scale value derived from the conical feeler's contacts. To evaluate the present tactile sensor, we have conducted a series of experiments using a y-z stage, a rotational stage, and a force gauge, and have found that although the relationship between the intergrated gray-scale value and nomal force depends on the sensor's latitude on the hemispherical surface, it is easy to modify the sensitivity according to the latitude, and that the centroid displacement of the gray-scale value is proportional to the shearing force. When we examined repeatability of the present tactile sensor with 1,000 load-unload cycles, the respective error of the normal and shearing forces was 2 and 5 %.}, pages = {214--219}, title = {Sensing Precision of an Optical Three-axis Tactile Sensor for a Robotic Finger}, year = {2006} }