{"created":"2021-03-01T06:14:31.237111+00:00","id":7841,"links":{},"metadata":{"_buckets":{"deposit":"087c9d45-9ccc-4fa5-a757-c28fd2ac35fa"},"_deposit":{"id":"7841","owners":[],"pid":{"revision_id":0,"type":"depid","value":"7841"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00007841","sets":["320:321:322"]},"author_link":["22379","22380","22381","22382","22383","22384","22385","22386"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"2388","bibliographicPageStart":"2385","bibliographic_titles":[{"bibliographic_title":"Solid-State Sensors, Actuators and Microsystems Conference","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have previously proposed a magnetic bead handling mechanism for micro-total-analysissystems [1-2] and have developed a palmtop-sized biochemical analysis system [3]. Appropriate agitation is one of the crucial issues in micro-meter-sized fluidic systems. We investigated the agitation produced by using multilayered flat coils and magnetic beads. The beads were magnetically agitated inside the droplet by changing the external magnetic field distribution, and the agitation performance was evaluated by using an enzymatic reaction. The reaction efficiency increased linearly with an increase in the reaction time and was more than four times as efficient with agitation than without agitation.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/9562"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/SENSOR.2007.4300650","subitem_relation_type_select":"DOI"}}]},"item_10_relation_8":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type":"isPartOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"1-4244-0842-3","subitem_relation_type_select":"ISBN"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2007 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Koyama, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22379","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nagano, N.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22380","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Imai, R.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22381","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shikida, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22382","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Honda, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22383","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okochi, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22384","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsuchiya, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22385","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sato, K.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22386","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-19"}],"displaytype":"detail","filename":"shik_09.pdf","filesize":[{"value":"349.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"shik_09.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/7841/files/shik_09.pdf"},"version_id":"1134677d-253f-4491-8c76-4c7d17e9012a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"magnetic beads","subitem_subject_scheme":"Other"},{"subitem_subject":"micro-TAS","subitem_subject_scheme":"Other"},{"subitem_subject":"agitation","subitem_subject_scheme":"Other"},{"subitem_subject":"flat coil","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Evaluation of Magnetic Beads Agitation Performance Operated by Multi-Layered Flat Coils","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Evaluation of Magnetic Beads Agitation Performance Operated by Multi-Layered Flat Coils","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["322"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-03-04"},"publish_date":"2008-03-04","publish_status":"0","recid":"7841","relation_version_is_last":true,"title":["Evaluation of Magnetic Beads Agitation Performance Operated by Multi-Layered Flat Coils"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:53:20.307811+00:00"}