{"_buckets": {"deposit": "3691614a-f442-4ced-8ebd-927a09cefc32"}, "_deposit": {"id": "8792", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "8792"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00008792", "sets": ["1048"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3-4", "bibliographicPageEnd": "88", "bibliographicPageStart": "83", "bibliographicVolumeNumber": "70", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Sleep disturbances manifesting as insomnia, daytime sleepiness, fatigue, and other symptoms are frequently found in patients with end-stage renal disease that is being treated with dialysis. Many factors, including neurosis, uremic symptoms, dialysis drugs, and sleep-wake rhythms have been suggested as potential causes for these sleep disturbances. We examined sleep apnea/hypopnea and heart rate variability (HRV) reflecting autonomic activity in hemodialysis patients on their hemodialysis and non-hemodialysis days using a home medical care device (Morpheus C, TEIJIN). Eleven hemodialysis patients and 14 healthy adults were enrolled in this study. We calculated the number of apnea/hypopnea episodes per hour (apnea/hypopnea index: AHI) and HRV (percentage of R-R intervals that differ by at least 50 ms from the previous interval: pNN50, very low frequency: VLF, low frequency: LF, high frequency: HF and LF/ HF). There was no significant difference in the AHI between hemodialysis and non-hemodialysis days. The heart rate in hemodialysis patients on non-hemodialysis days was significantly higher than in the controls, whereas the pNN50 was significantly lower in hemodialysis patients on non-hemodialysis days than in the controls. Although VLF was significantly lower in hemodialysis patients on non-hemodialysis days compared to the controls, there were no significant differences in LF, HF or LF/HF between the two groups. Hemodialysis itself might not be an important contributing factor in sleep-related breathing disturbances. The simultaneous analysis of HRV reflecting autonomic activity and sleep-disordered breathing on both hemodialysis and non-hemodialysis days provides important information.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/10544"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.70.3-4.83", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_9_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "SUKEGAWA, MAYO"}], "nameIdentifiers": [{"nameIdentifier": "24735", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NODA, AKIKO"}], "nameIdentifiers": [{"nameIdentifier": "24736", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SOGA, TARO"}], "nameIdentifiers": [{"nameIdentifier": "24737", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ADACHI, YUKI"}], "nameIdentifiers": [{"nameIdentifier": "24738", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TSURUTA, YOSHINARI"}], "nameIdentifiers": [{"nameIdentifier": "24739", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OZAKI, NORIO"}], "nameIdentifiers": [{"nameIdentifier": "24740", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KOIKE, YASUO"}], "nameIdentifiers": [{"nameIdentifier": "24741", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "助川, 真代"}], "nameIdentifiers": [{"nameIdentifier": "24742", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "p083-088_Sukegawa.pdf", "filesize": [{"value": "93.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 93300.0, "url": {"label": "p083-088_Sukegawa.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/8792/files/p083-088_Sukegawa.pdf"}, "version_id": "9abc1eca-13ab-4c70-88af-b5c13c49ac82"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Heart rate variability", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Sleep-disordered breathing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Hemodialysis", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "COMPARISON OF SLEEP-DISORDERED BREATHING AND HEART RATE VARIABILITY BETWEEN HEMODIALYSIS AND NON-HEMODIALYSIS DAYS IN HEMODIALYSIS PATIENTS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "COMPARISON OF SLEEP-DISORDERED BREATHING AND HEART RATE VARIABILITY BETWEEN HEMODIALYSIS AND NON-HEMODIALYSIS DAYS IN HEMODIALYSIS PATIENTS"}]}, "item_type_id": "9", "owner": "1", "path": ["1048"], "permalink_uri": "https://doi.org/10.18999/nagjms.70.3-4.83", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-09-22"}, "publish_date": "2008-09-22", "publish_status": "0", "recid": "8792", "relation": {}, "relation_version_is_last": true, "title": ["COMPARISON OF SLEEP-DISORDERED BREATHING AND HEART RATE VARIABILITY BETWEEN HEMODIALYSIS AND NON-HEMODIALYSIS DAYS IN HEMODIALYSIS PATIENTS"], "weko_shared_id": 3}
COMPARISON OF SLEEP-DISORDERED BREATHING AND HEART RATE VARIABILITY BETWEEN HEMODIALYSIS AND NON-HEMODIALYSIS DAYS IN HEMODIALYSIS PATIENTS
https://doi.org/10.18999/nagjms.70.3-4.83
https://doi.org/10.18999/nagjms.70.3-4.8355f57dca-0fc3-4dfb-a84a-681b954dd7db
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-09-22 | |||||
タイトル | ||||||
タイトル | COMPARISON OF SLEEP-DISORDERED BREATHING AND HEART RATE VARIABILITY BETWEEN HEMODIALYSIS AND NON-HEMODIALYSIS DAYS IN HEMODIALYSIS PATIENTS | |||||
著者 |
SUKEGAWA, MAYO
× SUKEGAWA, MAYO× NODA, AKIKO× SOGA, TARO× ADACHI, YUKI× TSURUTA, YOSHINARI× OZAKI, NORIO× KOIKE, YASUO× 助川, 真代 |
|||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Heart rate variability | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Sleep-disordered breathing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Hemodialysis | |||||
抄録 | ||||||
内容記述 | Sleep disturbances manifesting as insomnia, daytime sleepiness, fatigue, and other symptoms are frequently found in patients with end-stage renal disease that is being treated with dialysis. Many factors, including neurosis, uremic symptoms, dialysis drugs, and sleep-wake rhythms have been suggested as potential causes for these sleep disturbances. We examined sleep apnea/hypopnea and heart rate variability (HRV) reflecting autonomic activity in hemodialysis patients on their hemodialysis and non-hemodialysis days using a home medical care device (Morpheus C, TEIJIN). Eleven hemodialysis patients and 14 healthy adults were enrolled in this study. We calculated the number of apnea/hypopnea episodes per hour (apnea/hypopnea index: AHI) and HRV (percentage of R-R intervals that differ by at least 50 ms from the previous interval: pNN50, very low frequency: VLF, low frequency: LF, high frequency: HF and LF/ HF). There was no significant difference in the AHI between hemodialysis and non-hemodialysis days. The heart rate in hemodialysis patients on non-hemodialysis days was significantly higher than in the controls, whereas the pNN50 was significantly lower in hemodialysis patients on non-hemodialysis days than in the controls. Although VLF was significantly lower in hemodialysis patients on non-hemodialysis days compared to the controls, there were no significant differences in LF, HF or LF/HF between the two groups. Hemodialysis itself might not be an important contributing factor in sleep-related breathing disturbances. The simultaneous analysis of HRV reflecting autonomic activity and sleep-disordered breathing on both hemodialysis and non-hemodialysis days provides important information. | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
出版者 | Nagoya University School of Medicine | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.70.3-4.83 | |||||
ID登録タイプ | JaLC | |||||
ISSN(print) | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0027-7622 | |||||
書誌情報 |
Nagoya Journal of Medical Science 巻 70, 号 3-4, p. 83-88, 発行日 2008-08 |
|||||
フォーマット | ||||||
application/pdf | ||||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/10544 | |||||