{"created":"2021-03-01T06:16:07.614832+00:00","id":9363,"links":{},"metadata":{"_buckets":{"deposit":"9d454b9a-bafa-492c-aa10-7b0ffab4449a"},"_deposit":{"id":"9363","owners":[],"pid":{"revision_id":0,"type":"depid","value":"9363"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00009363","sets":["320:502:503"]},"author_link":["26779","26780","26781","26782","26783","26784","26785","26786"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"621","bibliographicPageStart":"618","bibliographic_titles":[{"bibliographic_title":"IEEE 21st International Conference on Micro Electro Mechanical Systems (MEMS 2008)","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We proposed novel type of a sample divider, which can easily divide the sample solution into multiple small amount of it on a chip, for single molecule analysis. We used the composite of a PDMS and an expancel^R as a material, and fabricated the sample divider structure by applying the mold process. We investigated the PDMS and the expancel mixture fraction dependency, and effect of the heating time, on the channel closing performance. The flow channels were successfully closed when the volume ratio between the expancel and PDMS solution was 1:2 and the heating time was 15 minutes. From these results, we concluded that the proposed device is useful as the sample divider, if we optimally designed.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/11138"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/MEMSYS.2008.4443732","subitem_relation_type_select":"DOI"}}]},"item_10_relation_8":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type":"isPartOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"978-1-4244-1793-3","subitem_relation_type_select":"ISBN"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2008 IEEE. Reprinted from IEEE 21st International Conference on Micro Electro Mechanical Systems, 2008, MEMS, p.618-621. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1084-6999","subitem_source_identifier_type":"PISSN"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Koyama, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26779","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Imai, R.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26780","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shikida, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26781","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okochi, M.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26782","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsuchiya, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26783","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Honda, H.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26784","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sato, K.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"26785","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤, 一雄","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"26786","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-20"}],"displaytype":"detail","filename":"08_MEMS_Koyama.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"08_MEMS_Koyama.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/9363/files/08_MEMS_Koyama.pdf"},"version_id":"d5181643-f55b-45ce-af0c-fa856335f3a4"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Micromachined sample divider for analyzing biochemical reaction based on single molecules","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Micromachined sample divider for analyzing biochemical reaction based on single molecules","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["503"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-02-23"},"publish_date":"2009-02-23","publish_status":"0","recid":"9363","relation_version_is_last":true,"title":["Micromachined sample divider for analyzing biochemical reaction based on single molecules"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T03:58:07.002450+00:00"}