{"created":"2021-03-01T06:16:47.365672+00:00","id":9987,"links":{},"metadata":{"_buckets":{"deposit":"0481def6-6185-464d-812d-6435e5f1ae75"},"_deposit":{"id":"9987","owners":[],"pid":{"revision_id":0,"type":"depid","value":"9987"},"status":"published"},"_oai":{"id":"oai:nagoya.repo.nii.ac.jp:00009987","sets":["673:674:675"]},"author_link":["30358","30359","30360","30361","30362","30363"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-04","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"275","bibliographicPageStart":"272","bibliographic_titles":[{"bibliographic_title":"International Conference on Condition Monitoring and Diagnosis (CMD 2008)","bibliographic_titleLang":"en"}]}]},"item_10_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Silicone oil has merits of less flammability and excellent environment-friendliness. High-viscosity silicone oil of 50 cSt has been widely applied to power and distribution transformers. Recently, application of low-viscosity silicone oil of 20 cSt to transformers has been considered for its excellent cooling performance. Detection of incipient fault conditions in low-viscosity silicone oil immersed transformers becomes more important when they are operated in electric power systems. Detection of certain gases generated in a transformer is usually the useful indication of an abnormal condition. To clarify its applicability to a low-viscosity silicone oil immersed transformer, this paper described gas characteristics generated by electrical discharges in detail. It was clarified that the identification of abnormal conditions are possible by considering the amounts and types of generated gases. Finally, gas characteristics were compared with those in 50 cSt silicone oil and mineral oil.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10_identifier_60":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2237/11797"}]},"item_10_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_10_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/CMD.2008.4580279","subitem_relation_type_select":"DOI"}}]},"item_10_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2008 IEEE. Reprinted from International Conference on Condition Monitoring and Diagnosis, 2008. CMD 2008. p.272-275. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.","subitem_rights_language":"en"}]},"item_10_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_10_text_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_text_value":"application/pdf"}]},"item_1615787544753":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Endo, Fumihiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30358","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamamoto, Shinpei","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30359","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sadakane, Takayuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30360","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamagishi, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30361","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Miyagi, Katsunori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30362","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Okubo, Hitoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"30363","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-20"}],"displaytype":"detail","filename":"CMD_C1-10.pdf","filesize":[{"value":"923.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"CMD_C1-10.pdf","objectType":"fulltext","url":"https://nagoya.repo.nii.ac.jp/record/9987/files/CMD_C1-10.pdf"},"version_id":"dfddb0af-be80-4b55-9d0b-9d77f21648c6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Silicone oil","subitem_subject_scheme":"Other"},{"subitem_subject":"Transformer","subitem_subject_scheme":"Other"},{"subitem_subject":"Dissolved gas analysis (DGA)","subitem_subject_scheme":"Other"},{"subitem_subject":"Diagnosis","subitem_subject_scheme":"Other"},{"subitem_subject":"Discharge","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Analysis of Gasses Generated by Electrical Discharges in Low Viscosity Silicone Oil","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Analysis of Gasses Generated by Electrical Discharges in Low Viscosity Silicone Oil","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["675"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-05-19"},"publish_date":"2009-05-19","publish_status":"0","recid":"9987","relation_version_is_last":true,"title":["Analysis of Gasses Generated by Electrical Discharges in Low Viscosity Silicone Oil"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-01-16T05:02:52.378706+00:00"}