{"_buckets": {"deposit": "5d132457-c0d6-4c0f-85d6-3341a3c24324"}, "_deposit": {"id": "10313", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "10313"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00010313", "sets": ["503"]}, "author_link": ["31274", "31275", "31276", "31277"], "control_number": "10313", "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "16", "bibliographicPageStart": "13", "bibliographicVolumeNumber": "1", "bibliographic_titles": [{"bibliographic_title": "23rd International Symposium on Discharges and Electrical Insulation in Vacuum, 2008. ISDEIV 2008", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Electrode conditioning in vacuum is very important technique for improvement of the insulation performance of vacuum circuit breakers (VCBs). This paper discusses the spark conditioning mechanism through the measurement and analysis of the pre-breakdown current under non-uniform field. From F-N plots, we made sure that the pre-breakdown current was based on field emission mechanism. We quantitatively evaluated the variation of pre-breakdown current in the conditioning process. As a result, field enhancement factor β decreased as the conditioning proceeded and reached the final value. In addition, in case of non-uniform field, we found that βon rod electrode surface after conditioning was distributed according to the electric field distribution on the surface.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "DOI", "subitem_identifier_uri": "http://dx.doi.org/10.1109/DEIV.2008.4676705"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/12133"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/DEIV.2008.4676705", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 2008 IEEE. Reprinted from 23rd International Symposium on Discharges and Electrical Insulation in Vacuum, 2008. ISDEIV 2008. v.1, p.13-16. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1093-2941", "subitem_source_identifier_type": "PISSN"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Okubo, Hitoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "31274", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuoka, Takanori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "31275", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kato, Tomohiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "31276", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kato, Katsumi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "31277", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ISDEIV-1.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "ISDEIV-1.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/10313/files/ISDEIV-1.pdf"}, "version_id": "828b307f-cfce-4ebd-9238-d2f29ce27224"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Electrode Conditioning Mechanism Based on Pre-breakdown Current under Non-uniform Electric Field in Vacuum", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Electrode Conditioning Mechanism Based on Pre-breakdown Current under Non-uniform Electric Field in Vacuum", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["503"], "permalink_uri": "http://hdl.handle.net/2237/12133", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-08-31"}, "publish_date": "2009-08-31", "publish_status": "0", "recid": "10313", "relation": {}, "relation_version_is_last": true, "title": ["Electrode Conditioning Mechanism Based on Pre-breakdown Current under Non-uniform Electric Field in Vacuum"], "weko_shared_id": -1}
  1. B200 工学部/工学研究科
  2. B200e 会議資料
  3. 国際会議

Electrode Conditioning Mechanism Based on Pre-breakdown Current under Non-uniform Electric Field in Vacuum

http://hdl.handle.net/2237/12133
http://hdl.handle.net/2237/12133
88108ff1-8887-4891-817b-eb76f0ce1048
名前 / ファイル ライセンス アクション
ISDEIV-1.pdf ISDEIV-1.pdf (1.1 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-08-31
タイトル
タイトル Electrode Conditioning Mechanism Based on Pre-breakdown Current under Non-uniform Electric Field in Vacuum
言語 en
著者 Okubo, Hitoshi

× Okubo, Hitoshi

WEKO 31274

en Okubo, Hitoshi

Search repository
Yasuoka, Takanori

× Yasuoka, Takanori

WEKO 31275

en Yasuoka, Takanori

Search repository
Kato, Tomohiro

× Kato, Tomohiro

WEKO 31276

en Kato, Tomohiro

Search repository
Kato, Katsumi

× Kato, Katsumi

WEKO 31277

en Kato, Katsumi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 Copyright © 2008 IEEE. Reprinted from 23rd International Symposium on Discharges and Electrical Insulation in Vacuum, 2008. ISDEIV 2008. v.1, p.13-16. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.
抄録
内容記述 Electrode conditioning in vacuum is very important technique for improvement of the insulation performance of vacuum circuit breakers (VCBs). This paper discusses the spark conditioning mechanism through the measurement and analysis of the pre-breakdown current under non-uniform field. From F-N plots, we made sure that the pre-breakdown current was based on field emission mechanism. We quantitatively evaluated the variation of pre-breakdown current in the conditioning process. As a result, field enhancement factor β decreased as the conditioning proceeded and reached the final value. In addition, in case of non-uniform field, we found that βon rod electrode surface after conditioning was distributed according to the electric field distribution on the surface.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 IEEE
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1109/DEIV.2008.4676705
ISSN
収録物識別子タイプ PISSN
収録物識別子 1093-2941
書誌情報 en : 23rd International Symposium on Discharges and Electrical Insulation in Vacuum, 2008. ISDEIV 2008

巻 1, p. 13-16, 発行日 2008-09
フォーマット
application/pdf
著者版フラグ
値 publisher
URI
識別子 http://dx.doi.org/10.1109/DEIV.2008.4676705
識別子タイプ DOI
URI
識別子 http://hdl.handle.net/2237/12133
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 19:31:12.805465
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3