{"_buckets": {"deposit": "198a56ed-1563-445f-a973-ceae944bb824"}, "_deposit": {"id": "11628", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "11628"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00011628", "sets": ["1235"]}, "item_9_alternative_title_19": {"attribute_name": "その他の言語のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "The examination of atmospheric \u003c14\u003e^CO measurement techniques (II)"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "169", "bibliographicPageStart": "164", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "名古屋大学加速器質量分析計業績報告書"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Atmospheric ^\u003c14\u003eCO can be used as a tracer of the global tropospheric hydroxyl radical (OH・) concentration. Hydroxyl radical is significantly responsible for the destruction of many sort of trace gas ; methane, carbon monoxide and so on. For collecting atmospheric carbon monoxide, a preparation line was remodeled from a methane preparation line. This line enriches carbon monoxide in about 1m^3 air by adsorption under low temperature. The enriched carbon monoxide is purified of other gas components with gas chromatography. The purified carbon monoxide is finally turned to carbon dioxide through the combustion tube in the preparation line. However, 1m^3 air include only about 0.1-1ml of carbon monoxide, it is not enough to ^\u003c14\u003eCO measurement by AMS (AMS need 1mg carbon or 2ml carbon dioxide). Thus, the carbon dioxide derived from the carbon monoxide in the air sample is diluted with the other carbon dioxide whose isotopic ratio is known. In this experiment, more than 3ml carbon monoxide separated from urban air was devided to three, and two of those were diluted with carbon dioxide whose isotopic ratio was known. Then, their ^\u003c14\u003eCO isotopic ratios were measured. The ratios of ^\u003c14\u003eC/^\u003c13\u003eC of atmospheric caron monoxide calculated with those of the diluted samples and their dilution rate were accordant to directly measured ^\u003c14\u003eC/^\u003c13\u003eC ratio of the not-diluted sample. However, errors of the calculated ratios became larger due to dilution. Hereafter, this preparation will be appraised and reconditioned to effectuate measurement of ^\u003c14\u003eC/^\u003c13\u003eC ratio in atmospheric carbon monoxide with the dilution method.", "subitem_description_type": "Abstract"}]}, "item_9_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "タンデトロン加速器質量分析計業績報告 Summaries of Researches Using AMS 1999 (平成11)年度", "subitem_description_type": "Other"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/sumrua.11.164", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "名古屋大学年代測定資料研究センター 天然放射性元素測定小委員会"}]}, "item_9_relation_43": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110000475642/", "subitem_relation_type_select": "URI"}}]}, "item_9_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "名古屋大学年代測定資料研究センター 天然放射性元素測定小委員会"}, {"subitem_rights": "本文データは学協会の許諾に基づきCiNiiから複製したものである"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "後藤, 晃彦"}], "nameIdentifiers": [{"nameIdentifier": "81017", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Goto, Akihiko"}], "nameIdentifiers": [{"nameIdentifier": "81018", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森泉, 純"}], "nameIdentifiers": [{"nameIdentifier": "81019", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Moriizumi, Jun"}], "nameIdentifiers": [{"nameIdentifier": "81020", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯田, 孝夫"}], "nameIdentifiers": [{"nameIdentifier": "81021", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iida, Takao"}], "nameIdentifiers": [{"nameIdentifier": "81022", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00000187350.pdf", "filesize": [{"value": "335.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 335100.0, "url": {"label": "KJ00000187350.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/11628/files/KJ00000187350.pdf"}, "version_id": "68e65b83-8d19-4ee4-b753-e3faf22f1aa9"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "大気中\u003c14\u003e^CO測定手法の検討(II)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "大気中\u003c14\u003e^CO測定手法の検討(II)"}]}, "item_type_id": "9", "owner": "1", "path": ["1235"], "permalink_uri": "https://doi.org/10.18999/sumrua.11.164", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-05-27"}, "publish_date": "2010-05-27", "publish_status": "0", "recid": "11628", "relation": {}, "relation_version_is_last": true, "title": ["大気中\u003c14\u003e^CO測定手法の検討(II)"], "weko_shared_id": null}
  1. F300 宇宙地球環境研究所
  2. F300b 紀要
  3. 名古屋大学加速器質量分析計業績報告書
  4. 11

大気中<14>^CO測定手法の検討(II)

https://doi.org/10.18999/sumrua.11.164
https://doi.org/10.18999/sumrua.11.164
7d69af0b-5d77-48a9-9321-0cf063c94c03
名前 / ファイル ライセンス アクション
KJ00000187350.pdf KJ00000187350.pdf (335.1 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2010-05-27
タイトル
タイトル 大気中<14>^CO測定手法の検討(II)
その他のタイトル
その他のタイトル The examination of atmospheric <14>^CO measurement techniques (II)
著者 後藤, 晃彦

× 後藤, 晃彦

WEKO 81017

後藤, 晃彦

Search repository
Goto, Akihiko

× Goto, Akihiko

WEKO 81018

Goto, Akihiko

Search repository
森泉, 純

× 森泉, 純

WEKO 81019

森泉, 純

Search repository
Moriizumi, Jun

× Moriizumi, Jun

WEKO 81020

Moriizumi, Jun

Search repository
飯田, 孝夫

× 飯田, 孝夫

WEKO 81021

飯田, 孝夫

Search repository
Iida, Takao

× Iida, Takao

WEKO 81022

Iida, Takao

Search repository
権利
権利情報 名古屋大学年代測定資料研究センター 天然放射性元素測定小委員会
権利
権利情報 本文データは学協会の許諾に基づきCiNiiから複製したものである
抄録
内容記述 Atmospheric ^<14>CO can be used as a tracer of the global tropospheric hydroxyl radical (OH・) concentration. Hydroxyl radical is significantly responsible for the destruction of many sort of trace gas ; methane, carbon monoxide and so on. For collecting atmospheric carbon monoxide, a preparation line was remodeled from a methane preparation line. This line enriches carbon monoxide in about 1m^3 air by adsorption under low temperature. The enriched carbon monoxide is purified of other gas components with gas chromatography. The purified carbon monoxide is finally turned to carbon dioxide through the combustion tube in the preparation line. However, 1m^3 air include only about 0.1-1ml of carbon monoxide, it is not enough to ^<14>CO measurement by AMS (AMS need 1mg carbon or 2ml carbon dioxide). Thus, the carbon dioxide derived from the carbon monoxide in the air sample is diluted with the other carbon dioxide whose isotopic ratio is known. In this experiment, more than 3ml carbon monoxide separated from urban air was devided to three, and two of those were diluted with carbon dioxide whose isotopic ratio was known. Then, their ^<14>CO isotopic ratios were measured. The ratios of ^<14>C/^<13>C of atmospheric caron monoxide calculated with those of the diluted samples and their dilution rate were accordant to directly measured ^<14>C/^<13>C ratio of the not-diluted sample. However, errors of the calculated ratios became larger due to dilution. Hereafter, this preparation will be appraised and reconditioned to effectuate measurement of ^<14>C/^<13>C ratio in atmospheric carbon monoxide with the dilution method.
内容記述タイプ Abstract
内容記述
内容記述 タンデトロン加速器質量分析計業績報告 Summaries of Researches Using AMS 1999 (平成11)年度
内容記述タイプ Other
出版者
出版者 名古屋大学年代測定資料研究センター 天然放射性元素測定小委員会
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/sumrua.11.164
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://ci.nii.ac.jp/naid/110000475642/
書誌情報 名古屋大学加速器質量分析計業績報告書

巻 11, p. 164-169, 発行日 2000-03
フォーマット
application/pdf
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 11:40:02.298639
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3