{"_buckets": {"deposit": "aa18e238-467d-48a3-9ba0-4c5b65ac30eb"}, "_deposit": {"id": "14169", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "14169"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00014169", "sets": ["614"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1994-12-26", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3-4", "bibliographicPageEnd": "132", "bibliographicPageStart": "127", "bibliographicVolumeNumber": "57", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Fundamental and clinical evaluation of chest CT imaging in detectability of pulmonary nodules was carried out in comparison with projection chest radiography including conventional screen-film system, advanced multiple beam equalization radiography (AMBER System), and computed radiography with imaging plate (CR). Detectability of simulated nodules in the fundamental study and of metastatic pulmonary nodules in ten patients in the clinical study was analysed by five radiologists. CT found the greatest number of nodules and also showed the highest sensitivity in detecting nodules of less than 5 mm in both the fundamental and clinical studies. The ability of computed tomography to visualize small pulmonary nodules may make it a possible substitute for chest radiography as the primary mass screening method, and as the examination method for small metastatic nodules (less than 5 mm) in patients with extrathoracic malignancy. There was no significant difference between conventional radiography, AMBER, and CR in the number of detected nodules.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.57.3-4.127", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine"}]}, "item_9_relation_43": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/5734/5734.html", "subitem_relation_type_select": "URI"}}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_61": {"attribute_name": "ISSN(Online)", "attribute_value_mlt": [{"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "MILLA, NICOLAS"}], "nameIdentifiers": [{"nameIdentifier": "98920", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ITO, KENGO"}], "nameIdentifiers": [{"nameIdentifier": "98921", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "IKEDA, MITSURU"}], "nameIdentifiers": [{"nameIdentifier": "98922", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NAKAMURA, KIYOKO"}], "nameIdentifiers": [{"nameIdentifier": "98923", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HIROSE, MITSUHIKO"}], "nameIdentifiers": [{"nameIdentifier": "98924", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ISHIGAKI, TAKEO"}], "nameIdentifiers": [{"nameIdentifier": "98925", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "v57n34p127_132.pdf", "filesize": [{"value": "421.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 421900.0, "url": {"label": "v57n34p127_132.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/14169/files/v57n34p127_132.pdf"}, "version_id": "37c5225c-cb88-49d5-8a5e-c20927d3cfaa"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Lung", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Chest X-plain", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Computed radiography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Advanced multiple beam equalization radiography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Pulmonary nodule", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Phantoms", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "FUNDAMENTAL AND CLINICAL EVALUATION OF CHEST COMPUTED TOMOGRAPHY IMAGING IN DETECTABILITY OF PULMONARY NODULE", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "FUNDAMENTAL AND CLINICAL EVALUATION OF CHEST COMPUTED TOMOGRAPHY IMAGING IN DETECTABILITY OF PULMONARY NODULE"}]}, "item_type_id": "9", "owner": "1", "path": ["614"], "permalink_uri": "https://doi.org/10.18999/nagjms.57.3-4.127", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-03-06"}, "publish_date": "2012-03-06", "publish_status": "0", "recid": "14169", "relation": {}, "relation_version_is_last": true, "title": ["FUNDAMENTAL AND CLINICAL EVALUATION OF CHEST COMPUTED TOMOGRAPHY IMAGING IN DETECTABILITY OF PULMONARY NODULE"], "weko_shared_id": null}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 57(3-4)

FUNDAMENTAL AND CLINICAL EVALUATION OF CHEST COMPUTED TOMOGRAPHY IMAGING IN DETECTABILITY OF PULMONARY NODULE

https://doi.org/10.18999/nagjms.57.3-4.127
https://doi.org/10.18999/nagjms.57.3-4.127
6d21f5fd-4fc3-49dc-97da-1ef827830398
名前 / ファイル ライセンス アクション
v57n34p127_132.pdf v57n34p127_132.pdf (421.9 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2012-03-06
タイトル
タイトル FUNDAMENTAL AND CLINICAL EVALUATION OF CHEST COMPUTED TOMOGRAPHY IMAGING IN DETECTABILITY OF PULMONARY NODULE
著者 MILLA, NICOLAS

× MILLA, NICOLAS

WEKO 98920

MILLA, NICOLAS

Search repository
ITO, KENGO

× ITO, KENGO

WEKO 98921

ITO, KENGO

Search repository
IKEDA, MITSURU

× IKEDA, MITSURU

WEKO 98922

IKEDA, MITSURU

Search repository
NAKAMURA, KIYOKO

× NAKAMURA, KIYOKO

WEKO 98923

NAKAMURA, KIYOKO

Search repository
HIROSE, MITSUHIKO

× HIROSE, MITSUHIKO

WEKO 98924

HIROSE, MITSUHIKO

Search repository
ISHIGAKI, TAKEO

× ISHIGAKI, TAKEO

WEKO 98925

ISHIGAKI, TAKEO

Search repository
キーワード
主題Scheme Other
主題 Lung
キーワード
主題Scheme Other
主題 Chest X-plain
キーワード
主題Scheme Other
主題 Computed radiography
キーワード
主題Scheme Other
主題 Advanced multiple beam equalization radiography
キーワード
主題Scheme Other
主題 Pulmonary nodule
キーワード
主題Scheme Other
主題 Phantoms
抄録
内容記述 Fundamental and clinical evaluation of chest CT imaging in detectability of pulmonary nodules was carried out in comparison with projection chest radiography including conventional screen-film system, advanced multiple beam equalization radiography (AMBER System), and computed radiography with imaging plate (CR). Detectability of simulated nodules in the fundamental study and of metastatic pulmonary nodules in ten patients in the clinical study was analysed by five radiologists. CT found the greatest number of nodules and also showed the highest sensitivity in detecting nodules of less than 5 mm in both the fundamental and clinical studies. The ability of computed tomography to visualize small pulmonary nodules may make it a possible substitute for chest radiography as the primary mass screening method, and as the examination method for small metastatic nodules (less than 5 mm) in patients with extrathoracic malignancy. There was no significant difference between conventional radiography, AMBER, and CR in the number of detected nodules.
内容記述タイプ Abstract
出版者
出版者 Nagoya University School of Medicine
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/nagjms.57.3-4.127
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/5734/5734.html
ISSN(print)
収録物識別子タイプ ISSN
収録物識別子 0027-7622
ISSN(Online)
収録物識別子タイプ ISSN
収録物識別子 2186-3326
書誌情報 Nagoya Journal of Medical Science

巻 57, 号 3-4, p. 127-132, 発行日 1994-12-26
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:12:11.665375
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3