{"_buckets": {"deposit": "6a420aaf-ccbe-494a-9835-9599a587db01"}, "_deposit": {"id": "14197", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "14197"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00014197", "sets": ["617"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1996-03-29", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-2", "bibliographicPageEnd": "62", "bibliographicPageStart": "55", "bibliographicVolumeNumber": "59", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We investigated the usefulness of the oxygen intake efficiency slope (OIES) as a submaximal measure of cardiorespiratory functional reserve. OIES was derived from the relationship between oxygen consumption (VO2; ml/min) and minute ventilation (VE; l/min) during incremental exercise, which was determined by the following equation: VO2 = a logVE + b, where \"a\" represents OIES, which shows the effectiveness of ventilation. Maximal oxygen consumption (VO2max) is effort-dependent. There is no standard submaximal measurement of cardiorespiratory reserve that provides generally acceptable results. Exercise tests were performed by 17 normal volunteers on an ergometer using a symptom-limited Ramp protocol. Expired gas was continuously analyzed. OIES was calculated using the first 75%, 90%, and 100% of exercise data. We also determined the following submaximal parameters: the ventilatory anaerobic threshold (VAT), the slope of the minute ventilation-carbon dioxide production relationship (VE-VCO2 slope), and the extrapolated maximal oxygen consumption (EMOC). We analyzed the relationship between OIES, other submaximal parameters and VO2max, and examined the effects of submaximal exercise on OIES. The correlation coefficient of the logarithmic curve-fitting model was 0.991 +/- 0.006. OIES and VO2max were significantly correlated (r = 0.966, p \u003c 0.0001). The correlation between OIES and VO2max was stronger than the correlation between VO2max and VAT, the VE-VCO2 slope and EMOC. OIES values for 100% and 90% of exercise were identical; OIES for 75% of exercise was slightly lower (3%). Our results suggested that OIES may provide an objective, effort-independent estimation of cardiorespiratory functional reserve.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/5912/5912.html"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/16102"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.59.1-2.55", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "BABA, REIZO"}], "nameIdentifiers": [{"nameIdentifier": "44206", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NAGASHIMA, MASAMI"}], "nameIdentifiers": [{"nameIdentifier": "44207", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "GOTO, MASAHIKO"}], "nameIdentifiers": [{"nameIdentifier": "44208", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NAGANO, YOSHIKO"}], "nameIdentifiers": [{"nameIdentifier": "44209", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "YOKOTA, MITSUHIRO"}], "nameIdentifiers": [{"nameIdentifier": "44210", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TAUCHI, NOBUO"}], "nameIdentifiers": [{"nameIdentifier": "44211", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NISHIBATA, KENJI"}], "nameIdentifiers": [{"nameIdentifier": "44212", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "v59n12p55_62.pdf", "filesize": [{"value": "554.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 554600.0, "url": {"label": "v59n12p55_62.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/14197/files/v59n12p55_62.pdf"}, "version_id": "160e818b-299b-4b78-99df-1f881884ad0d"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Oxygen intake efficienty slope", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Anaerobic threshold", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Extrapolated maximal ocygen consumption", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Exercise testing", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "OXYGEN INTAKE EFFICIENCY SLOPE: A NEW INDEX OF CARDIORESPIRATORY FUNCTIONAL RESERVE DERIVED FROM THE RELATIONSHIP BETWEEN OXYGEN CONSUMPTION AND MINUTE VENTILATION DURING INCREMENTAL EXERCISE", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "OXYGEN INTAKE EFFICIENCY SLOPE: A NEW INDEX OF CARDIORESPIRATORY FUNCTIONAL RESERVE DERIVED FROM THE RELATIONSHIP BETWEEN OXYGEN CONSUMPTION AND MINUTE VENTILATION DURING INCREMENTAL EXERCISE"}]}, "item_type_id": "9", "owner": "1", "path": ["617"], "permalink_uri": "https://doi.org/10.18999/nagjms.59.1-2.55", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-03-12"}, "publish_date": "2012-03-12", "publish_status": "0", "recid": "14197", "relation": {}, "relation_version_is_last": true, "title": ["OXYGEN INTAKE EFFICIENCY SLOPE: A NEW INDEX OF CARDIORESPIRATORY FUNCTIONAL RESERVE DERIVED FROM THE RELATIONSHIP BETWEEN OXYGEN CONSUMPTION AND MINUTE VENTILATION DURING INCREMENTAL EXERCISE"], "weko_shared_id": null}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 59(1-2)

OXYGEN INTAKE EFFICIENCY SLOPE: A NEW INDEX OF CARDIORESPIRATORY FUNCTIONAL RESERVE DERIVED FROM THE RELATIONSHIP BETWEEN OXYGEN CONSUMPTION AND MINUTE VENTILATION DURING INCREMENTAL EXERCISE

https://doi.org/10.18999/nagjms.59.1-2.55
https://doi.org/10.18999/nagjms.59.1-2.55
001b8116-1065-4db3-9b69-587713696799
名前 / ファイル ライセンス アクション
v59n12p55_62.pdf v59n12p55_62.pdf (554.6 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2012-03-12
タイトル
タイトル OXYGEN INTAKE EFFICIENCY SLOPE: A NEW INDEX OF CARDIORESPIRATORY FUNCTIONAL RESERVE DERIVED FROM THE RELATIONSHIP BETWEEN OXYGEN CONSUMPTION AND MINUTE VENTILATION DURING INCREMENTAL EXERCISE
著者 BABA, REIZO

× BABA, REIZO

WEKO 44206

BABA, REIZO

Search repository
NAGASHIMA, MASAMI

× NAGASHIMA, MASAMI

WEKO 44207

NAGASHIMA, MASAMI

Search repository
GOTO, MASAHIKO

× GOTO, MASAHIKO

WEKO 44208

GOTO, MASAHIKO

Search repository
NAGANO, YOSHIKO

× NAGANO, YOSHIKO

WEKO 44209

NAGANO, YOSHIKO

Search repository
YOKOTA, MITSUHIRO

× YOKOTA, MITSUHIRO

WEKO 44210

YOKOTA, MITSUHIRO

Search repository
TAUCHI, NOBUO

× TAUCHI, NOBUO

WEKO 44211

TAUCHI, NOBUO

Search repository
NISHIBATA, KENJI

× NISHIBATA, KENJI

WEKO 44212

NISHIBATA, KENJI

Search repository
キーワード
主題Scheme Other
主題 Oxygen intake efficienty slope
キーワード
主題Scheme Other
主題 Anaerobic threshold
キーワード
主題Scheme Other
主題 Extrapolated maximal ocygen consumption
キーワード
主題Scheme Other
主題 Exercise testing
抄録
内容記述 We investigated the usefulness of the oxygen intake efficiency slope (OIES) as a submaximal measure of cardiorespiratory functional reserve. OIES was derived from the relationship between oxygen consumption (VO2; ml/min) and minute ventilation (VE; l/min) during incremental exercise, which was determined by the following equation: VO2 = a logVE + b, where "a" represents OIES, which shows the effectiveness of ventilation. Maximal oxygen consumption (VO2max) is effort-dependent. There is no standard submaximal measurement of cardiorespiratory reserve that provides generally acceptable results. Exercise tests were performed by 17 normal volunteers on an ergometer using a symptom-limited Ramp protocol. Expired gas was continuously analyzed. OIES was calculated using the first 75%, 90%, and 100% of exercise data. We also determined the following submaximal parameters: the ventilatory anaerobic threshold (VAT), the slope of the minute ventilation-carbon dioxide production relationship (VE-VCO2 slope), and the extrapolated maximal oxygen consumption (EMOC). We analyzed the relationship between OIES, other submaximal parameters and VO2max, and examined the effects of submaximal exercise on OIES. The correlation coefficient of the logarithmic curve-fitting model was 0.991 +/- 0.006. OIES and VO2max were significantly correlated (r = 0.966, p < 0.0001). The correlation between OIES and VO2max was stronger than the correlation between VO2max and VAT, the VE-VCO2 slope and EMOC. OIES values for 100% and 90% of exercise were identical; OIES for 75% of exercise was slightly lower (3%). Our results suggested that OIES may provide an objective, effort-independent estimation of cardiorespiratory functional reserve.
内容記述タイプ Abstract
出版者
出版者 Nagoya University School of Medicine
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/nagjms.59.1-2.55
ID登録タイプ JaLC
ISSN(print)
収録物識別子タイプ ISSN
収録物識別子 0027-7622
書誌情報 Nagoya Journal of Medical Science

巻 59, 号 1-2, p. 55-62, 発行日 1996-03-29
著者版フラグ
値 publisher
URI
識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/5912/5912.html
識別子タイプ URI
URI
識別子 http://hdl.handle.net/2237/16102
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 18:12:43.837728
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3