WEKO3
アイテム
段階的加熱を用いた14C試料調製
https://doi.org/10.18999/sumrua.22.225
https://doi.org/10.18999/sumrua.22.2257394767b-5520-49c2-9429-f83f2d630046
名前 / ファイル | ライセンス | アクション |
---|---|---|
sumrua_22_225.pdf (1.4 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-06-06 | |||||
タイトル | ||||||
タイトル | 段階的加熱を用いた14C試料調製 | |||||
言語 | ja | |||||
その他のタイトル | ||||||
その他のタイトル | 14C sample preparation with stepwise heating | |||||
言語 | en | |||||
著者 |
南, 雅代
× 南, 雅代× 宮田, 佳樹× 中村, 俊夫× Minami, Masayo× Miyata, Yoshiki× Nakamura, Toshio |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Stepwise heating | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 14C age | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | δ13C | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Graphitization | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Sulfix reagent | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 段階的加熱 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 14C年代 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 炭素安定同位体比 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | グラファイト化 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | サルフィックス試薬 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The effects of stepwise heating of sample, addition of not only CuO but also Cu and Ag in a sealed tube on sample combustion, and use of a n-pentane/liq.N2 trap and/or a Sulfix reagent on sample CO2 purification upon sample graphitization, 14C ages and δ13C values were investigated. The sample used is a filter made from PES including sulfur. The sample combustion by stepwise heating was more effective in complete conversion of carbon in samples to CO2, and the addition of Cu and Ag on sample combustion was effective in removal of sulfur contained in sample. Furthermore, the treatment of sample C02 using a Sulfix reagent became worse the measurement precision of 14C and δ13C values probably due to isotopic fractionation during reaction of sample CO2 with Sulfix. From the results, the best sample preparation method for 14C ages and δl3C analysis could be that a sample is combusted with CuO, Cu and Ag by stepwise heating. Purification of CO2 extracted from the sample using n-pentane/liq.N2 trap could not be needed in this preparation method. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | 名古屋大学年代測定資料研究センター | |||||
言語 | ja | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/sumrua.22.225 | |||||
ID登録タイプ | JaLC | |||||
書誌情報 |
ja : 名古屋大学加速器質量分析計業績報告書 巻 22, p. 225-228, 発行日 2011-03 |
|||||
著者版フラグ | ||||||
値 | publisher |