ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "6e41f479-827c-43ab-8963-6681d0ddf95a"}, "_deposit": {"id": "15374", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "15374"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00015374", "sets": ["1450"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1981-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-2", "bibliographicPageEnd": "40", "bibliographicPageStart": "31", "bibliographicVolumeNumber": "44", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This paper examined the availability of a method for calculating the \"mean elastic constant\" of tissue and its practical applicability. The error analysis for the elastic constant of tissue was obtained by theoretical and experimental methods. Its error depends on measured lengths from Computerized Tomograms (CT), Ultrasonograms (US), CT-values and their deviations. This method can be accurately applied to soft tissue and organs of 4 cm or more with an error of less than 20% in vivo with the exception of bone, lungs, and gas filled organs. The procedure we employed for obtaining the \"mean elastic constant\" by combining CT with US is presented.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/4412/4412.html"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/17392"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.44.1-2.31", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_61": {"attribute_name": "ISSN(Online)", "attribute_value_mlt": [{"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "OHARA, KEN"}], "nameIdentifiers": [{"nameIdentifier": "46856", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SAKUMA, SADAYUKI"}], "nameIdentifiers": [{"nameIdentifier": "46857", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "v44n12p31_40.pdf", "filesize": [{"value": "936.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 936400.0, "url": {"label": "v44n12p31_40.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/15374/files/v44n12p31_40.pdf"}, "version_id": "56e68f06-883b-417b-9443-a609a7fceec5"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Tissue Characterization", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mean Elastic Constant", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Computerized Tomography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Ultrasonography", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Error Analysis for Measurement of Tissue Elastic Constant and its Practical Application", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Error Analysis for Measurement of Tissue Elastic Constant and its Practical Application"}]}, "item_type_id": "9", "owner": "1", "path": ["1450"], "permalink_uri": "https://doi.org/10.18999/nagjms.44.1-2.31", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-01-24"}, "publish_date": "2013-01-24", "publish_status": "0", "recid": "15374", "relation": {}, "relation_version_is_last": true, "title": ["Error Analysis for Measurement of Tissue Elastic Constant and its Practical Application"], "weko_shared_id": 3}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 44(1-2)

Error Analysis for Measurement of Tissue Elastic Constant and its Practical Application

https://doi.org/10.18999/nagjms.44.1-2.31
https://doi.org/10.18999/nagjms.44.1-2.31
162021d7-877e-4fdf-af7a-0988d3ae58b7
名前 / ファイル ライセンス アクション
v44n12p31_40.pdf v44n12p31_40.pdf (936.4 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2013-01-24
タイトル
タイトル Error Analysis for Measurement of Tissue Elastic Constant and its Practical Application
著者 OHARA, KEN

× OHARA, KEN

WEKO 46856

OHARA, KEN

Search repository
SAKUMA, SADAYUKI

× SAKUMA, SADAYUKI

WEKO 46857

SAKUMA, SADAYUKI

Search repository
キーワード
主題Scheme Other
主題 Tissue Characterization
キーワード
主題Scheme Other
主題 Mean Elastic Constant
キーワード
主題Scheme Other
主題 Computerized Tomography
キーワード
主題Scheme Other
主題 Ultrasonography
抄録
内容記述 This paper examined the availability of a method for calculating the "mean elastic constant" of tissue and its practical applicability. The error analysis for the elastic constant of tissue was obtained by theoretical and experimental methods. Its error depends on measured lengths from Computerized Tomograms (CT), Ultrasonograms (US), CT-values and their deviations. This method can be accurately applied to soft tissue and organs of 4 cm or more with an error of less than 20% in vivo with the exception of bone, lungs, and gas filled organs. The procedure we employed for obtaining the "mean elastic constant" by combining CT with US is presented.
内容記述タイプ Abstract
出版者
出版者 Nagoya University School of Medicine
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/nagjms.44.1-2.31
ID登録タイプ JaLC
ISSN(print)
収録物識別子タイプ ISSN
収録物識別子 0027-7622
ISSN(Online)
収録物識別子タイプ ISSN
収録物識別子 2186-3326
書誌情報 Nagoya Journal of Medical Science

巻 44, 号 1-2, p. 31-40, 発行日 1981-11
著者版フラグ
値 publisher
URI
識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/4412/4412.html
識別子タイプ URI
URI
識別子 http://hdl.handle.net/2237/17392
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:16:02.569174
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3