WEKO3
アイテム
The Scale Method as a Spectral Analysis for Accommodative Fluctuation
https://doi.org/10.18999/nagjms.49.1-4.31
https://doi.org/10.18999/nagjms.49.1-4.3140508ea3-2d96-46d6-af9c-34114c8bc64d
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-02-13 | |||||
タイトル | ||||||
タイトル | The Scale Method as a Spectral Analysis for Accommodative Fluctuation | |||||
言語 | en | |||||
著者 |
MIYAO, MASARU
× MIYAO, MASARU× TANAHASHI, MASAKO× TOMIYASU, SEISHI× AKAMATSU, YASUHIRO× KUNO, HIROSHI× IGUCHI, HIROKAZU× KONDO, TAKA'AKI× SAKAKIBARA, HISATAKA× FURUTA, MASASHI× YAMADA, SHIN'YA× ONO, YUICHIRO |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Fluctuations of Accommodation | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Spectral Analysis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Infrared Optometer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Scale Method | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | VDT | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Visual Load | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Power Spectrum | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A scale method of computer analysis was developed as an automatic spectral analysis system of the accommodative fluctuations. The scale approach employed a computer to identify wave peaks. Using this new system, spectral analysis of the fluctuations in accommodation measured by an infrared optometer was performed. Both the power spectrum method and the scale method were used to perform a spectral analysis and a wave form analysis. The spectrum peaks obtained by both methods were virtually coincidental. Twenty sec was adequate for the measuring time examined from the viewpoint of data stability. Fluctuations in accommodation were measured in 17 adult males. The mean peak frequency band range in 18 eyes of the young group was 2.5-3.15 Hz, in contrast to 1.25-1.6 Hz in 16 eyes of the middle-aged group. The newly developed system was considered effective as a criterion for visual load in VDT (visual display terminal) work and other high-level visual tasks. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Nagoya University School of Medicine | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.49.1-4.31 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/4914/4914.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 49, 号 1-4, p. 31-39, 発行日 1987-03 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/17496 | |||||
識別子タイプ | HDL |