ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "726a3a4b-c189-49aa-99a9-64a428835ed0"}, "_deposit": {"id": "15589", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "15589"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00015589", "sets": ["1468"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-2", "bibliographicPageEnd": "123", "bibliographicPageStart": "121", "bibliographicVolumeNumber": "75", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Exposure of the mitral valve is of critical importance in mitral valve surgery. The mitral valve is located near the interatrial groove. As we accumulated experience and learned from embryology, we found that a more central left atriotomy was advantageous, and was made possible by interatrial groove dissection using an ultrasonic scalpel. This crucial finding prompted us to report the technique.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/7512/7512.html"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/17608"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.75.1-2.121", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "SONG, MIN-HO"}], "nameIdentifiers": [{"nameIdentifier": "47503", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "13_Song1.pdf", "filesize": [{"value": "4.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 4900000.0, "url": {"label": "13_Song1.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/15589/files/13_Song1.pdf"}, "version_id": "e00f4d61-7390-4950-97a4-a76235868b24"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Mitral valve", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Interatrial groove", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mitral valve surgery", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Advantage of a More Central Incision onto Left Atrium by Using Ultrasonic Scalpel", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Advantage of a More Central Incision onto Left Atrium by Using Ultrasonic Scalpel"}]}, "item_type_id": "9", "owner": "1", "path": ["1468"], "permalink_uri": "https://doi.org/10.18999/nagjms.75.1-2.121", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-03-01"}, "publish_date": "2013-03-01", "publish_status": "0", "recid": "15589", "relation": {}, "relation_version_is_last": true, "title": ["Advantage of a More Central Incision onto Left Atrium by Using Ultrasonic Scalpel"], "weko_shared_id": null}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 75(1-2)

Advantage of a More Central Incision onto Left Atrium by Using Ultrasonic Scalpel

https://doi.org/10.18999/nagjms.75.1-2.121
https://doi.org/10.18999/nagjms.75.1-2.121
213c3e90-e962-400e-982e-e6350d2102bb
名前 / ファイル ライセンス アクション
13_Song1.pdf 13_Song1.pdf (4.9 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2013-03-01
タイトル
タイトル Advantage of a More Central Incision onto Left Atrium by Using Ultrasonic Scalpel
著者 SONG, MIN-HO

× SONG, MIN-HO

WEKO 47503

SONG, MIN-HO

Search repository
キーワード
主題Scheme Other
主題 Mitral valve
キーワード
主題Scheme Other
主題 Interatrial groove
キーワード
主題Scheme Other
主題 Mitral valve surgery
抄録
内容記述 Exposure of the mitral valve is of critical importance in mitral valve surgery. The mitral valve is located near the interatrial groove. As we accumulated experience and learned from embryology, we found that a more central left atriotomy was advantageous, and was made possible by interatrial groove dissection using an ultrasonic scalpel. This crucial finding prompted us to report the technique.
内容記述タイプ Abstract
出版者
出版者 Nagoya University School of Medicine
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/nagjms.75.1-2.121
ID登録タイプ JaLC
ISSN(print)
収録物識別子タイプ ISSN
収録物識別子 0027-7622
書誌情報 Nagoya Journal of Medical Science

巻 75, 号 1-2, p. 121-123, 発行日 2013-02
著者版フラグ
値 publisher
URI
識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/7512/7512.html
識別子タイプ URI
URI
識別子 http://hdl.handle.net/2237/17608
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 17:49:24.303495
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3