WEKO3
アイテム
The Prevention of Intravascular Thrombosis Based Upon Electric Properties
https://doi.org/10.18999/nagjms.30.4.373
https://doi.org/10.18999/nagjms.30.4.3739aa9792a-5b19-4eb2-8a48-4a99a5dbea5e
名前 / ファイル | ライセンス | アクション |
---|---|---|
v30n4p373_396.pdf (4.9 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-09-26 | |||||
タイトル | ||||||
タイトル | The Prevention of Intravascular Thrombosis Based Upon Electric Properties | |||||
言語 | en | |||||
著者 |
IWAYA, KAZUO
× IWAYA, KAZUO |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Although many theories have been reported as to the cause of venous thrombus, the three factors listed and explained by Virchow are still widely accepted. Various experimental studies have been done based upon the assumption that the disturbance in blood vessel intima was the main causing factor for the formation of thrombus due to mechanical or chemical injuries to the intima. A report was made by Abramson in 1927 as to the negative charge nature of the surface of blood cells, and later in 1953, Sawyer et al., reported that the intima of blood vessels was negatively charged in the physiological condition, and that thrombus was not caused by the electric repulsion of the blood cells and the intima. Furthermore, it was said that when the intima was mechanically or chemically injured, the negative charge of the intima underwent reversion of polarity, and the thrombus formed. This investigation was carried out in vitro by using autoradiography to deter· mine the necessary intensity of electricity, duration of electrification, and other factors which were required for the formation of thrombus by positive charge under normal condition. At the same time, to test the effect of thrombus prevention, experiments using negative charge were conducted in which the intima was mechanically injured to easily make thrombus. And, after applying electrification, the intimal surface of the blood vessel was observed microscopically. Negative charge was applied to the transplantation of artificial blood vessel for vein. Wrinkled teflon graft about 3 cm in length was transplanted to the inferior vena cava of an adult dog. A platinum electrode was coiled around the part of end to end anastomosis and electrified as a negative electrode. After a certain period of time, patency was examined by venography. Patent cases were all of very early stage of electrification, and no thrombus formation occurred with a case of negative electrode of platinum coil used to prevent kinking and pressing. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Nagoya University School of Medicine | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.30.4.373 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/304/304.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 30, 号 4, p. 373-397, 発行日 1968-03 |
|||||
著者版フラグ | ||||||
値 | publisher |