ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C100 医学部/医学系研究科
  2. C100b 刊行物
  3. Nagoya journal of medical science
  4. 30(4)

The Prevention of Intravascular Thrombosis Based Upon Electric Properties

https://doi.org/10.18999/nagjms.30.4.373
https://doi.org/10.18999/nagjms.30.4.373
9aa9792a-5b19-4eb2-8a48-4a99a5dbea5e
名前 / ファイル ライセンス アクション
v30n4p373_396.pdf v30n4p373_396.pdf (4.9 MB)
アイテムタイプ 紀要論文 / Departmental Bulletin Paper(1)
公開日 2013-09-26
タイトル
タイトル The Prevention of Intravascular Thrombosis Based Upon Electric Properties
言語 en
著者 IWAYA, KAZUO

× IWAYA, KAZUO

WEKO 96210

en IWAYA, KAZUO

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
抄録
内容記述タイプ Abstract
内容記述 Although many theories have been reported as to the cause of venous thrombus, the three factors listed and explained by Virchow are still widely accepted. Various experimental studies have been done based upon the assumption that the disturbance in blood vessel intima was the main causing factor for the formation of thrombus due to mechanical or chemical injuries to the intima. A report was made by Abramson in 1927 as to the negative charge nature of the surface of blood cells, and later in 1953, Sawyer et al., reported that the intima of blood vessels was negatively charged in the physiological condition, and that thrombus was not caused by the electric repulsion of the blood cells and the intima. Furthermore, it was said that when the intima was mechanically or chemically injured, the negative charge of the intima underwent reversion of polarity, and the thrombus formed. This investigation was carried out in vitro by using autoradiography to deter· mine the necessary intensity of electricity, duration of electrification, and other factors which were required for the formation of thrombus by positive charge under normal condition. At the same time, to test the effect of thrombus prevention, experiments using negative charge were conducted in which the intima was mechanically injured to easily make thrombus. And, after applying electrification, the intimal surface of the blood vessel was observed microscopically. Negative charge was applied to the transplantation of artificial blood vessel for vein. Wrinkled teflon graft about 3 cm in length was transplanted to the inferior vena cava of an adult dog. A platinum electrode was coiled around the part of end to end anastomosis and electrified as a negative electrode. After a certain period of time, patency was examined by venography. Patent cases were all of very early stage of electrification, and no thrombus formation occurred with a case of negative electrode of platinum coil used to prevent kinking and pressing.
言語 en
出版者
出版者 Nagoya University School of Medicine
言語 en
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.30.4.373
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/304/304.html
ISSN(print)
収録物識別子タイプ PISSN
収録物識別子 0027-7622
ISSN(Online)
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 30, 号 4, p. 373-397, 発行日 1968-03
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:36:58.778221
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3