{"_buckets": {"deposit": "2ebb8649-de45-4f50-ab04-c2ae1cea6778"}, "_deposit": {"id": "17309", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "17309"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00017309", "sets": ["501"]}, "author_link": ["50891", "50892", "50893", "50894", "50895", "50896", "50897"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1981-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "817", "bibliographicPageStart": "815", "bibliographicVolumeNumber": "22", "bibliographic_titles": [{"bibliographic_title": "Journal of nuclear medicine : official publication, Society of Nuclear Medicine", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A technique is described for transaxial imaging of the thorax during pulmonary perfusion study. The contours of the air-containing lungs were obtained by gamma-ray transmission data from a Tc-99m plane flood source. These images were overlaid on the emission tomogram of the pulmonary blood flow obtained with Tc-99m MAA. It permits reliable detection of peripheral perfusion defects. Use of the results from these measurements can be applied to evaluate marginal hypoperfusions of the lungs.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://jnm.snmjournals.org/content/22/9/815.long"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/19394"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Society of Nuclear Medicine and Molecular Imaging", "subitem_publisher_language": "en"}]}, "item_10_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://jnm.snmjournals.org/content/22/9/815.long", "subitem_relation_type_select": "URI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "This research was originally published in JNM. Maeda Hisatoshi, ltoh Harumi, lshii Yasushi, Mukai Takao, Todo Giro, Fujita Toru, Torizuka Kanji. Determination of the pleural edge by gamma-ray transmission computed tomography. J Nucl Med. 1981;vol:22(9) pp815-pp817. © by the Society of Nuclear Medicine and Molecular Imaging, Inc.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0161-5505", "subitem_source_identifier_type": "PISSN"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Maeda, Hisatoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "50891", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ltoh, Harumi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "50892", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "lshii, Yasushi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "50893", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mukai, Takao", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "50894", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Todo, Giro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "50895", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujita, Toru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "50896", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Torizuka, Kanji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "50897", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "7_DeterminationOfPleuralEdge.PDF", "filesize": [{"value": "487.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 487500.0, "url": {"label": "7_DeterminationOfPleuralEdge.PDF", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/17309/files/7_DeterminationOfPleuralEdge.PDF"}, "version_id": "80302247-176c-4391-b171-60167dccaf91"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Determination of the pleural edge by gamma-ray transmission computed tomography", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Determination of the pleural edge by gamma-ray transmission computed tomography", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["501"], "permalink_uri": "http://hdl.handle.net/2237/19394", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2014-02-20"}, "publish_date": "2014-02-20", "publish_status": "0", "recid": "17309", "relation": {}, "relation_version_is_last": true, "title": ["Determination of the pleural edge by gamma-ray transmission computed tomography"], "weko_shared_id": -1}
  1. C100 医学部/医学系研究科
  2. C100a 雑誌掲載論文
  3. 学術雑誌

Determination of the pleural edge by gamma-ray transmission computed tomography

http://hdl.handle.net/2237/19394
http://hdl.handle.net/2237/19394
d2ac42de-40ef-49f1-807a-216e15d4de98
名前 / ファイル ライセンス アクション
7_DeterminationOfPleuralEdge.PDF 7_DeterminationOfPleuralEdge.PDF (487.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-02-20
タイトル
タイトル Determination of the pleural edge by gamma-ray transmission computed tomography
言語 en
著者 Maeda, Hisatoshi

× Maeda, Hisatoshi

WEKO 50891

en Maeda, Hisatoshi

Search repository
ltoh, Harumi

× ltoh, Harumi

WEKO 50892

en ltoh, Harumi

Search repository
lshii, Yasushi

× lshii, Yasushi

WEKO 50893

en lshii, Yasushi

Search repository
Mukai, Takao

× Mukai, Takao

WEKO 50894

en Mukai, Takao

Search repository
Todo, Giro

× Todo, Giro

WEKO 50895

en Todo, Giro

Search repository
Fujita, Toru

× Fujita, Toru

WEKO 50896

en Fujita, Toru

Search repository
Torizuka, Kanji

× Torizuka, Kanji

WEKO 50897

en Torizuka, Kanji

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 This research was originally published in JNM. Maeda Hisatoshi, ltoh Harumi, lshii Yasushi, Mukai Takao, Todo Giro, Fujita Toru, Torizuka Kanji. Determination of the pleural edge by gamma-ray transmission computed tomography. J Nucl Med. 1981;vol:22(9) pp815-pp817. © by the Society of Nuclear Medicine and Molecular Imaging, Inc.
抄録
内容記述 A technique is described for transaxial imaging of the thorax during pulmonary perfusion study. The contours of the air-containing lungs were obtained by gamma-ray transmission data from a Tc-99m plane flood source. These images were overlaid on the emission tomogram of the pulmonary blood flow obtained with Tc-99m MAA. It permits reliable detection of peripheral perfusion defects. Use of the results from these measurements can be applied to evaluate marginal hypoperfusions of the lungs.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 Society of Nuclear Medicine and Molecular Imaging
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://jnm.snmjournals.org/content/22/9/815.long
ISSN
収録物識別子タイプ PISSN
収録物識別子 0161-5505
書誌情報 en : Journal of nuclear medicine : official publication, Society of Nuclear Medicine

巻 22, 号 9, p. 815-817, 発行日 1981-09
著者版フラグ
値 publisher
URI
識別子 http://jnm.snmjournals.org/content/22/9/815.long
識別子タイプ URI
URI
識別子 http://hdl.handle.net/2237/19394
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 17:11:58.840605
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3