Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry

http://hdl.handle.net/2237/20614
http://hdl.handle.net/2237/20614
53fa1dab-7731-451d-87b8-77a675ffc5de
名前 / ファイル ライセンス アクション
Medical_Physics_paer_Phantom_correction_factor.pdf Medical_Physics_paer_Phantom_correction_factor.pdf (372.8 kB)
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2014-10-24
タイトル
タイトル Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry
言語 en
著者 Araki, Fujio

× Araki, Fujio

WEKO 53820

en Araki, Fujio

Search repository
Hanyu, Yuji

× Hanyu, Yuji

WEKO 53821

en Hanyu, Yuji

Search repository
Fukuoka, Miyoko

× Fukuoka, Miyoko

WEKO 53822

en Fukuoka, Miyoko

Search repository
Matsumoto, Kenji

× Matsumoto, Kenji

WEKO 53823

en Matsumoto, Kenji

Search repository
Okumura, Masahiko

× Okumura, Masahiko

WEKO 53824

en Okumura, Masahiko

Search repository
Oguchi, Hiroshi

× Oguchi, Hiroshi

WEKO 53825

en Oguchi, Hiroshi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報 © 2009 American Association of Physicists in Medicine
言語 en
キーワード
主題Scheme Other
主題 water-to-plastic ionization conversion factor
キーワード
主題Scheme Other
主題 fluence correction factor
キーワード
主題Scheme Other
主題 wall correction factor
キーワード
主題Scheme Other
主題 chamber-dependent fluence correction factor
キーワード
主題Scheme Other
主題 Monte Carlo calculations
抄録
内容記述タイプ Abstract
内容記述 The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k(pl) for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials in the range of 4-18 MV photon beams. For electron beams, a depth-scaling factor c(pl) and a chamber-dependent fluence correction factor h(pl) for both phantoms were also calculated in combination with NACP-02 and Roos plane-parallel ionization chambers in the range of 4-18 MeV. The h(pl) values for the plane-parallel chambers were evaluated from the electron fluence correction factor phi(pl)w and wall correction factors P(wall,w) and P(wall,pl) for a combination of water or plastic materials. The calculated k(pl) and h(pl) values were verified by comparison with the measured values. A set of k(pl) values computed for the Farmer-type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The k(pl) values also agreed within their combined uncertainty with the measured data. For electron beams, the c(pl) values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4-18 MeV. The phi(pl)w values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4-18 MeV. The difference in P(wall) between water and plastic materials for the plane-parallel chambers was 0.8% at a maximum. Finally, h(pl) values evaluated for plastic materials were equal to unity within 0.6% for NACP-02 and Roos chambers. The h(pl) values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.
言語 en
出版者
出版者 AIP Publishing
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1118/1.3151809
ISSN
収録物識別子タイプ PISSN
収録物識別子 0094-2405
書誌情報 en : Medical Physics

巻 36, 号 7, p. 2992-3001, 発行日 2009-07
著者版フラグ
値 author
URI
識別子 http://dx.doi.org/10.1118/1.3151809
識別子タイプ DOI
URI
識別子 http://hdl.handle.net/2237/20614
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 16:38:17.774551
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3