{"_buckets": {"deposit": "fa284b0c-6513-4217-a06b-808c7c2d47d0"}, "_deposit": {"id": "19165", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "19165"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00019165", "sets": ["1674"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-2", "bibliographicPageEnd": "194", "bibliographicPageStart": "189", "bibliographicVolumeNumber": "77", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Double-balloon endoscopy (DBE) can be used to treat disorders of the small intestine and can also be used to retrieve foreign bodies from the small intestine without surgery. We describe the findings of 22 cases in which DBE was used to try and retrieve foreign bodies from the small intestine. The foreign bodies included 12 capsule endoscopes, 3 artificial teeth, 3 medical tubes, 2 worms, 1 press-through packet of medicine, and 1 intestinal stone. The retrieval success rate was 86.3% (19/22), and there were no complications related to the retrieval procedures. Snare forceps were the most useful device for grasping the foreign bodies, and DBE was usually performed via an oral route. If an anal route is selected in cases involving stenosis of the small intestine, endoscopic balloon dilation will be necessary to reach the target. In conclusion, DBE is very useful for extracting foreign bodies from the small intestine, and the careful selection of the DBE route and the removal device are important for successfully retrieving foreign bodies.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/7712.html"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/21271"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.77.1-2.189", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "NAKAMURA, MASANAO"}], "nameIdentifiers": [{"nameIdentifier": "56049", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HIROOKA, YOSHIKI"}], "nameIdentifiers": [{"nameIdentifier": "56050", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "WATANABE, OSAMU"}], "nameIdentifiers": [{"nameIdentifier": "56051", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "YAMAMURA, TAKESHI"}], "nameIdentifiers": [{"nameIdentifier": "56052", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NAGURA, ASUKA"}], "nameIdentifiers": [{"nameIdentifier": "56053", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "YOSHIMURA, TORU"}], "nameIdentifiers": [{"nameIdentifier": "56054", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NAKANO, ARIHIRO"}], "nameIdentifiers": [{"nameIdentifier": "56055", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ANDO, TAKAFUMI"}], "nameIdentifiers": [{"nameIdentifier": "56056", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OHMIYA, NAOKI"}], "nameIdentifiers": [{"nameIdentifier": "56057", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "GOTO, HIDEMI"}], "nameIdentifiers": [{"nameIdentifier": "56058", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "25_Nakamura.pdf", "filesize": [{"value": "449.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 449000.0, "url": {"label": "25_Nakamura.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/19165/files/25_Nakamura.pdf"}, "version_id": "b3d9ac94-3a72-492c-b807-60e9ff071865"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "foreign body", "subitem_subject_scheme": "Other"}, {"subitem_subject": "double-balloon endoscopy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "capsule endoscopy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "retention", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Minimally Invasive Extraction of a Foreign Body from the Small Intestine Using Double-Balloon Endoscopy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Minimally Invasive Extraction of a Foreign Body from the Small Intestine Using Double-Balloon Endoscopy"}]}, "item_type_id": "9", "owner": "1", "path": ["1674"], "permalink_uri": "https://doi.org/10.18999/nagjms.77.1-2.189", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-02-27"}, "publish_date": "2015-02-27", "publish_status": "0", "recid": "19165", "relation": {}, "relation_version_is_last": true, "title": ["Minimally Invasive Extraction of a Foreign Body from the Small Intestine Using Double-Balloon Endoscopy"], "weko_shared_id": null}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 77(1-2)

Minimally Invasive Extraction of a Foreign Body from the Small Intestine Using Double-Balloon Endoscopy

https://doi.org/10.18999/nagjms.77.1-2.189
https://doi.org/10.18999/nagjms.77.1-2.189
51d9d9d0-0e07-49d4-b0f0-2624a0e0536e
名前 / ファイル ライセンス アクション
25_Nakamura.pdf 25_Nakamura.pdf (449.0 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2015-02-27
タイトル
タイトル Minimally Invasive Extraction of a Foreign Body from the Small Intestine Using Double-Balloon Endoscopy
著者 NAKAMURA, MASANAO

× NAKAMURA, MASANAO

WEKO 56049

NAKAMURA, MASANAO

Search repository
HIROOKA, YOSHIKI

× HIROOKA, YOSHIKI

WEKO 56050

HIROOKA, YOSHIKI

Search repository
WATANABE, OSAMU

× WATANABE, OSAMU

WEKO 56051

WATANABE, OSAMU

Search repository
YAMAMURA, TAKESHI

× YAMAMURA, TAKESHI

WEKO 56052

YAMAMURA, TAKESHI

Search repository
NAGURA, ASUKA

× NAGURA, ASUKA

WEKO 56053

NAGURA, ASUKA

Search repository
YOSHIMURA, TORU

× YOSHIMURA, TORU

WEKO 56054

YOSHIMURA, TORU

Search repository
NAKANO, ARIHIRO

× NAKANO, ARIHIRO

WEKO 56055

NAKANO, ARIHIRO

Search repository
ANDO, TAKAFUMI

× ANDO, TAKAFUMI

WEKO 56056

ANDO, TAKAFUMI

Search repository
OHMIYA, NAOKI

× OHMIYA, NAOKI

WEKO 56057

OHMIYA, NAOKI

Search repository
GOTO, HIDEMI

× GOTO, HIDEMI

WEKO 56058

GOTO, HIDEMI

Search repository
キーワード
主題Scheme Other
主題 foreign body
キーワード
主題Scheme Other
主題 double-balloon endoscopy
キーワード
主題Scheme Other
主題 capsule endoscopy
キーワード
主題Scheme Other
主題 retention
抄録
内容記述 Double-balloon endoscopy (DBE) can be used to treat disorders of the small intestine and can also be used to retrieve foreign bodies from the small intestine without surgery. We describe the findings of 22 cases in which DBE was used to try and retrieve foreign bodies from the small intestine. The foreign bodies included 12 capsule endoscopes, 3 artificial teeth, 3 medical tubes, 2 worms, 1 press-through packet of medicine, and 1 intestinal stone. The retrieval success rate was 86.3% (19/22), and there were no complications related to the retrieval procedures. Snare forceps were the most useful device for grasping the foreign bodies, and DBE was usually performed via an oral route. If an anal route is selected in cases involving stenosis of the small intestine, endoscopic balloon dilation will be necessary to reach the target. In conclusion, DBE is very useful for extracting foreign bodies from the small intestine, and the careful selection of the DBE route and the removal device are important for successfully retrieving foreign bodies.
内容記述タイプ Abstract
出版者
出版者 Nagoya University School of Medicine
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/nagjms.77.1-2.189
ID登録タイプ JaLC
ISSN(print)
収録物識別子タイプ ISSN
収録物識別子 0027-7622
書誌情報 Nagoya Journal of Medical Science

巻 77, 号 1-2, p. 189-194, 発行日 2015-02
著者版フラグ
値 publisher
URI
識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/7712.html
識別子タイプ URI
URI
識別子 http://hdl.handle.net/2237/21271
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 16:20:32.267818
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3