ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "1e0f3e8d-9744-4f8e-867e-5c8b62fd1934"}, "_deposit": {"id": "2002114", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2002114"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:02002114", "sets": ["1646019880489"]}, "author_link": [], "control_number": "2002114", "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "18", "bibliographicPageStart": "7", "bibliographicVolumeNumber": "84", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "This study aimed to examine the reliability and validity of using a smartphone to measure the multi-joint range of motion of the lower limbs. We measured the straight leg raise angle, ankle dorsiflexion angle, and hip internal rotation angle in each of the 40 lower extremities of 20 healthy adults. Measurements were compared between a conventional method using a goniometer and a smartphone application method. The intraclass correlation coefficient (ICC) was used to evaluate the reliability of each smartphone measurement, and Bland–Altman analysis was used to examine measurement errors. The criterion-related validity of the two methods was also examined. Intra-rater reliability (ICC 0.668–0.939) was substantial to almost perfect, with no systematic errors found for all items, and the standard errors of measurement were acceptable. Inter-rater reliability (ICC 0.701–0.936) was also substantial to almost perfect, but the straight leg raise angle and hip internal rotation angle showed fixation errors. For these two measurements, with more than one examiner, the limit of agreement of error needs to be considered. No systematic errors were found in the ankle dorsiflexion angle, and the standard error of measurement was within the acceptable range. A moderate to strong correlation (r = 0.626–0.915) was found between the conventional and smartphone methods, demonstrating good criterion-related validity. However, in the ankle dorsiflexion angle measurements, the reliability and validity were shown to be lower than the other two items. This suggested the necessity of changing the measurement conditions in order to use the ankle dorsiflexion angle in clinical practice.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/).", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.84.1.7", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University Graduate School of Medicine, School of Medicine", "subitem_publisher_language": "en"}]}, "item_9_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/841.html", "subitem_relation_type_select": "URI"}}]}, "item_9_source_id_7": {"attribute_name": "収録物識別子", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "PISSN"}, {"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "EISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Miyachi, Yousuke", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Ito, Morihiro", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Furuta, Kunihiro", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Ban, Rua", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Hanamura, Shuntaro", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Kamiya, Mitsuhiro", "creatorNameLang": "en"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2022-02-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "02_Miyachi.pdf", "filesize": [{"value": "14.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "application/pdf", "size": 14400000.0, "url": {"objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/2002114/files/02_Miyachi.pdf"}, "version_id": "70aaab17-be4e-46ea-bfb4-8050040ea3e6"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "reliability", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "validity", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "smartphone", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "range of motion", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "measurement", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Reliability and validity of lower limb joint range of motion measurements using a smartphone", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Reliability and validity of lower limb joint range of motion measurements using a smartphone", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "1", "path": ["1646019880489"], "permalink_uri": "https://doi.org/10.18999/nagjms.84.1.7", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2022-02-28"}, "publish_date": "2022-02-28", "publish_status": "0", "recid": "2002114", "relation": {}, "relation_version_is_last": true, "title": ["Reliability and validity of lower limb joint range of motion measurements using a smartphone"], "weko_shared_id": -1}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 84(1)

Reliability and validity of lower limb joint range of motion measurements using a smartphone

https://doi.org/10.18999/nagjms.84.1.7
https://doi.org/10.18999/nagjms.84.1.7
28562a3e-8a78-46dd-9bbf-129a07a3bd6d
名前 / ファイル ライセンス アクション
02_Miyachi.pdf 02_Miyachi.pdf (14.4 MB)
Item type itemtype_ver1(1)
公開日 2022-02-28
タイトル
タイトル Reliability and validity of lower limb joint range of motion measurements using a smartphone
言語 en
著者 Miyachi, Yousuke

× Miyachi, Yousuke

en Miyachi, Yousuke

Search repository
Ito, Morihiro

× Ito, Morihiro

en Ito, Morihiro

Search repository
Furuta, Kunihiro

× Furuta, Kunihiro

en Furuta, Kunihiro

Search repository
Ban, Rua

× Ban, Rua

en Ban, Rua

Search repository
Hanamura, Shuntaro

× Hanamura, Shuntaro

en Hanamura, Shuntaro

Search repository
Kamiya, Mitsuhiro

× Kamiya, Mitsuhiro

en Kamiya, Mitsuhiro

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
キーワード
言語 en
主題Scheme Other
主題 reliability
キーワード
言語 en
主題Scheme Other
主題 validity
キーワード
言語 en
主題Scheme Other
主題 smartphone
キーワード
言語 en
主題Scheme Other
主題 range of motion
キーワード
言語 en
主題Scheme Other
主題 measurement
内容記述
内容記述 This study aimed to examine the reliability and validity of using a smartphone to measure the multi-joint range of motion of the lower limbs. We measured the straight leg raise angle, ankle dorsiflexion angle, and hip internal rotation angle in each of the 40 lower extremities of 20 healthy adults. Measurements were compared between a conventional method using a goniometer and a smartphone application method. The intraclass correlation coefficient (ICC) was used to evaluate the reliability of each smartphone measurement, and Bland–Altman analysis was used to examine measurement errors. The criterion-related validity of the two methods was also examined. Intra-rater reliability (ICC 0.668–0.939) was substantial to almost perfect, with no systematic errors found for all items, and the standard errors of measurement were acceptable. Inter-rater reliability (ICC 0.701–0.936) was also substantial to almost perfect, but the straight leg raise angle and hip internal rotation angle showed fixation errors. For these two measurements, with more than one examiner, the limit of agreement of error needs to be considered. No systematic errors were found in the ankle dorsiflexion angle, and the standard error of measurement was within the acceptable range. A moderate to strong correlation (r = 0.626–0.915) was found between the conventional and smartphone methods, demonstrating good criterion-related validity. However, in the ankle dorsiflexion angle measurements, the reliability and validity were shown to be lower than the other two items. This suggested the necessity of changing the measurement conditions in order to use the ankle dorsiflexion angle in clinical practice.
言語 en
内容記述タイプ Abstract
内容記述
内容記述 This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/).
言語 en
内容記述タイプ Other
出版者
言語 en
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.84.1.7
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/841.html
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0027-7622
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 84, 号 1, p. 7-18, 発行日 2022-02
戻る
0
views
See details
Views

Versions

Ver.1 2022-02-28 04:30:15.912531
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3