{"_buckets": {"deposit": "1cb4480d-7807-40a8-b961-d708a96c8cb8"}, "_deposit": {"created_by": 17, "id": "2002217", "owner": "17", "owners": [17], "owners_ext": {"displayname": "図書情報係", "username": "repository"}, "pid": {"revision_id": 0, "type": "depid", "value": "2002217"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:02002217", "sets": ["501"]}, "author_link": [], "control_number": "2002217", "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_1629683748249": {"attribute_name": "日付", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2022-11-01", "subitem_date_issued_type": "Available"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "177", "bibliographicPageStart": "172", "bibliographicVolumeNumber": "49", "bibliographic_titles": [{"bibliographic_title": "The American Journal of Emergency Medicine", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Background: Airborne personal protective equipment is required for healthcare workers when performing aerosol-generating procedures on patients with infectious diseases. Chest compressions, one of the main components of cardiopulmonary resuscitation, require intense and dynamic movements of the upper body. We aimed to investigate the protective effect of tight-fitting powered air-purifying respirators (PAPRs) during chest compressions. Methods: This single-center simulation study was performed from February 2021 to March 2021. The simulated workplace protection factor (SWPF) is the concentration ratio of ambient particles and particles inside the PAPR mask; this value indicates the level of protection provided by a respirator when subjected to a simulated work environment. Participants performed continuous chest compressions three times for 2 min each time, with a 4-min break between each session. We measured the SWPF of the tight-fitting PAPR during chest compression in real-time mode. The primary outcome was the ratio of any failure of protection (SWPF \u003c500) during the chest compression sessions. Results: Fifty-four participants completed the simulation. Overall, 78% (n = 42) of the participants failed (the measured SWPF value was less than 500) at least one of the three sessions of chest compressions. The median value and interquartile range of the SWPF was 4304 (685–16,191). There were no reports of slipping down of the respirator or mechanical failure during chest compressions. Conclusions: Although the median SWPF value was high during chest compressions, the tight-fitting PAPR did not provide adequate protection.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier", "subitem_publisher_language": "en"}]}, "item_9_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1016/j.ajem.2021.06.012", "subitem_relation_type_select": "DOI"}}]}, "item_9_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/", "subitem_rights_language": "en"}]}, "item_9_source_id_7": {"attribute_name": "収録物識別子", "attribute_value_mlt": [{"subitem_source_identifier": "0735-6757", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Goto, Yukari", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Jingushi, Naruhiro", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Hiraiwa, Hiroaki", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Ogawa, Hiroaki", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Sakai, Yoshinori", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Kasugai, Daisuke", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Tanaka, Taku", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Higashi, Michiko", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Yamamoto, Takanori", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Numaguchi, Atsushi", "creatorNameLang": "en"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-11-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Manuscript_PAPR.pdf", "filesize": [{"value": "678 KB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "mimetype": "application/pdf", "size": 678000.0, "url": {"objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/2002217/files/Manuscript_PAPR.pdf"}, "version_id": "3ad28cf9-94df-49f3-be36-4e783a500427"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Powered air-purifying respirators", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Aerosol-generating procedures", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Chest compression", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "The protective effect of tight-fitting powered air-purifying respirators during chest compressions", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "The protective effect of tight-fitting powered air-purifying respirators during chest compressions", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "17", "path": ["501"], "permalink_uri": "http://hdl.handle.net/2237/0002002217", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2022-03-14"}, "publish_date": "2022-03-14", "publish_status": "0", "recid": "2002217", "relation": {}, "relation_version_is_last": true, "title": ["The protective effect of tight-fitting powered air-purifying respirators during chest compressions"], "weko_shared_id": -1}
  1. C100 医学部/医学系研究科
  2. C100a 雑誌掲載論文
  3. 学術雑誌

The protective effect of tight-fitting powered air-purifying respirators during chest compressions

http://hdl.handle.net/2237/0002002217
http://hdl.handle.net/2237/0002002217
6405f4af-7320-44b5-9c89-f3421ef11d25
名前 / ファイル ライセンス アクション
Manuscript_PAPR.pdf Manuscript_PAPR.pdf (678 KB)
Item type itemtype_ver1(1)
公開日 2022-03-14
タイトル
タイトル The protective effect of tight-fitting powered air-purifying respirators during chest compressions
言語 en
著者 Goto, Yukari

× Goto, Yukari

en Goto, Yukari

Search repository
Jingushi, Naruhiro

× Jingushi, Naruhiro

en Jingushi, Naruhiro

Search repository
Hiraiwa, Hiroaki

× Hiraiwa, Hiroaki

en Hiraiwa, Hiroaki

Search repository
Ogawa, Hiroaki

× Ogawa, Hiroaki

en Ogawa, Hiroaki

Search repository
Sakai, Yoshinori

× Sakai, Yoshinori

en Sakai, Yoshinori

Search repository
Kasugai, Daisuke

× Kasugai, Daisuke

en Kasugai, Daisuke

Search repository
Tanaka, Taku

× Tanaka, Taku

en Tanaka, Taku

Search repository
Higashi, Michiko

× Higashi, Michiko

en Higashi, Michiko

Search repository
Yamamoto, Takanori

× Yamamoto, Takanori

en Yamamoto, Takanori

Search repository
Numaguchi, Atsushi

× Numaguchi, Atsushi

en Numaguchi, Atsushi

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 © 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
キーワード
主題Scheme Other
主題 Powered air-purifying respirators
キーワード
主題Scheme Other
主題 Aerosol-generating procedures
キーワード
主題Scheme Other
主題 Chest compression
内容記述
内容記述 Background: Airborne personal protective equipment is required for healthcare workers when performing aerosol-generating procedures on patients with infectious diseases. Chest compressions, one of the main components of cardiopulmonary resuscitation, require intense and dynamic movements of the upper body. We aimed to investigate the protective effect of tight-fitting powered air-purifying respirators (PAPRs) during chest compressions. Methods: This single-center simulation study was performed from February 2021 to March 2021. The simulated workplace protection factor (SWPF) is the concentration ratio of ambient particles and particles inside the PAPR mask; this value indicates the level of protection provided by a respirator when subjected to a simulated work environment. Participants performed continuous chest compressions three times for 2 min each time, with a 4-min break between each session. We measured the SWPF of the tight-fitting PAPR during chest compression in real-time mode. The primary outcome was the ratio of any failure of protection (SWPF <500) during the chest compression sessions. Results: Fifty-four participants completed the simulation. Overall, 78% (n = 42) of the participants failed (the measured SWPF value was less than 500) at least one of the three sessions of chest compressions. The median value and interquartile range of the SWPF was 4304 (685–16,191). There were no reports of slipping down of the respirator or mechanical failure during chest compressions. Conclusions: Although the median SWPF value was high during chest compressions, the tight-fitting PAPR did not provide adequate protection.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 Elsevier
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連情報
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.ajem.2021.06.012
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0735-6757
書誌情報 en : The American Journal of Emergency Medicine

巻 49, p. 172-177, 発行日 2021-11
ファイル公開日
日付 2022-11-01
日付タイプ Available
戻る
0
views
See details
Views

Versions

Ver.1 2022-03-14 04:37:02.246452
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3