The protective effect of tight-fitting powered air-purifying respirators during chest compressions |
|
言語 |
en |
著者 |
Goto, Yukari
Jingushi, Naruhiro
Hiraiwa, Hiroaki
Ogawa, Hiroaki
Sakai, Yoshinori
Kasugai, Daisuke
Tanaka, Taku
Higashi, Michiko
Yamamoto, Takanori
Numaguchi, Atsushi
|
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
権利 |
|
|
言語 |
en |
|
権利情報 |
© 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Powered air-purifying respirators |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Aerosol-generating procedures |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Chest compression |
内容記述 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Background: Airborne personal protective equipment is required for healthcare workers when performing aerosol-generating procedures on patients with infectious diseases. Chest compressions, one of the main components of cardiopulmonary resuscitation, require intense and dynamic movements of the upper body. We aimed to investigate the protective effect of tight-fitting powered air-purifying respirators (PAPRs) during chest compressions. Methods: This single-center simulation study was performed from February 2021 to March 2021. The simulated workplace protection factor (SWPF) is the concentration ratio of ambient particles and particles inside the PAPR mask; this value indicates the level of protection provided by a respirator when subjected to a simulated work environment. Participants performed continuous chest compressions three times for 2 min each time, with a 4-min break between each session. We measured the SWPF of the tight-fitting PAPR during chest compression in real-time mode. The primary outcome was the ratio of any failure of protection (SWPF <500) during the chest compression sessions. Results: Fifty-four participants completed the simulation. Overall, 78% (n = 42) of the participants failed (the measured SWPF value was less than 500) at least one of the three sessions of chest compressions. The median value and interquartile range of the SWPF was 4304 (685–16,191). There were no reports of slipping down of the respirator or mechanical failure during chest compressions. Conclusions: Although the median SWPF value was high during chest compressions, the tight-fitting PAPR did not provide adequate protection. |
|
言語 |
en |
出版者 |
|
|
出版者 |
Elsevier |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
出版タイプ |
|
|
出版タイプ |
AM |
|
出版タイプResource |
http://purl.org/coar/version/c_ab4af688f83e57aa |
関連情報 |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.1016/j.ajem.2021.06.012 |
収録物識別子 |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
0735-6757 |
書誌情報 |
en : The American Journal of Emergency Medicine
巻 49,
p. 172-177,
発行日 2021-11
|
ファイル公開日 |
|
|
日付 |
2022-11-01 |
|
日付タイプ |
Available |