{"_buckets": {"deposit": "1cb4966a-1973-4ef4-b94c-3d1236c250ff"}, "_deposit": {"id": "2004216", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2004216"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:02004216", "sets": []}, "author_link": [], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "889", "bibliographicPageStart": "884", "bibliographicVolumeNumber": "84", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Thromboembolic complications are a concern in the treatment of cerebral aneurysms using a flow diverter. In this study, we report a case of abnormal foreshortening of a Flow Re-Direction Endoluminal Device (FRED) caused by in-stent thrombosis immediately after its deployment. A 72-year-old woman had a large cavernous carotid aneurysm, which caused ptosis and diplopia. FRED deployment was planned, and dual antiplatelet therapy was initiated 2 weeks before the procedure. Under systemic heparinization, FRED was deployed with local compaction over the aneurysm orifice. Cone-beam computed tomography subsequently revealed slightly poor wall apposition at the proximal side. While the balloon catheter was prepared for angioplasty, the stent became abnormally foreshortened, the proximal side slipped into the aneurysm, and the internal carotid artery became occluded. FRED was removed using a snare wire, and recanalization was obtained. The lumen of the removed FRED was filled with thrombus. The antiplatelet therapy was changed to triple regimen, and a Pipeline Flex embolization device was placed 1 month later. At that time, no thromboembolic complications were noted. It was considered that thrombotic occlusion was followed by foreshortening of FRED on the distal side because of antegrade blood flow. Multiple factors, such as increased mesh density by locally compacted stent deployment, slightly poor wall apposition, clopidogrel resistance, and the dual-layer structure of FRED, may have been involved in thrombus formation.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.84.4.884", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University Graduate School of Medicine, School of Medicine", "subitem_publisher_language": "en"}]}, "item_9_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/844.html", "subitem_relation_type_select": "URI"}}]}, "item_9_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International", "subitem_rights_language": "en", "subitem_rights_resource": "http://creativecommons.org/licenses/by-nc-nd/4.0/"}]}, "item_9_source_id_7": {"attribute_name": "収録物識別子", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "PISSN"}, {"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "EISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Otsuka, Takafumi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Izumi, Takashi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Nishihori, Masahiro", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Tsukada, Tetsuya", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Goto, Shunsaku", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Ikezawa, Mizuka", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Kato, Naoki", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Nakano, Mizuki", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Uda, Kenji", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Yokoyama, Kinya", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Araki, Yoshio", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Saito, Ryuta", "creatorNameLang": "en"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2022-11-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "20_Otsuka.pdf", "filesize": [{"value": "1.3 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_5", "mimetype": "application/pdf", "size": 1300000.0, "url": {"objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/2004216/files/20_Otsuka.pdf"}, "version_id": "923db06a-1126-4809-8378-bb5b04759200"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "flow diverter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Flow Re-Direction Endoluminal Device", "subitem_subject_scheme": "Other"}, {"subitem_subject": "thromboembolic complications", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Abnormal foreshortening of a Flow Re-Direction Endoluminal Device caused by in-stent thrombosis immediately after deployment", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Abnormal foreshortening of a Flow Re-Direction Endoluminal Device caused by in-stent thrombosis immediately after deployment", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "1", "path": ["1669094631719"], "permalink_uri": "https://doi.org/10.18999/nagjms.84.4.884", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2022-11-22"}, "publish_date": "2022-11-22", "publish_status": "0", "recid": "2004216", "relation": {}, "relation_version_is_last": true, "title": ["Abnormal foreshortening of a Flow Re-Direction Endoluminal Device caused by in-stent thrombosis immediately after deployment"], "weko_shared_id": -1}
Abnormal foreshortening of a Flow Re-Direction Endoluminal Device caused by in-stent thrombosis immediately after deployment
https://doi.org/10.18999/nagjms.84.4.884
https://doi.org/10.18999/nagjms.84.4.884