ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "d9e39f38-aab3-4698-a2df-291be33276a9"}, "_deposit": {"created_by": 17, "id": "2006268", "owners": [17], "pid": {"revision_id": 0, "type": "depid", "value": "2006268"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:02006268", "sets": ["1685060434835"]}, "author_link": [], "control_number": "2006268", "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2023-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "309", "bibliographicPageStart": "299", "bibliographicVolumeNumber": "85", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "In the evaluation of endolymphatic hydrops (EH) using magnetic resonance (MR) imaging, hybrid of reversed image of positive endolymph signal and native image of perilymph signal multiplied with heavily T2-weighted MR cisternography (HYDROPS-Mi2) imaging with the intravenous administration of a gadolinium-based contrast agent (IV-GBCA) has been utilized. Recently, MR cisternography (MRC) without GBCA has been proposed as a potential alternative method. However, the feasibility of EH evaluation by MRC without GBCA has not been established. The present study aimed to compare HYDROPS-Mi2 imaging with IV-GBCA to MRC without IV-GBCA for the evaluation of EH. In 40 ears of 20 patients with clinically suspected EH, MRC at pre-IV-GBCA and HYDROPS-Mi2 images from 4 h post-IV-GBCA were analyzed. The saccular height on the MRC (SH-MRC) was measured. The percentage of the volume of the endolymphatic space within the whole lymphatic space of the vestibule on the HYDROPS-Mi2 image (%ELvolume-HYD) was measured. The correlation between the SH-MRC and %ELvolume-HYD was calculated. The receiver operating characteristic (ROC) of the SH-MRC and %ELvolume-HYD for the clinical diagnosis of EH was evaluated. The Spearman’s rank correlation coefficient between the SH-MRC and %ELvolume-HYD was 0.102. The areas under the ROC curve were 0.570 for the SH-MRC, and 0.926 for the %ELvolume-HYD. In conclusion, there was no significant correlation between the MRC without IV-GBCA and the HYDOROPS-Mi2 with IV-GBCA in the evaluation of EH.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/).", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.85.2.299", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University Graduate School of Medicine, School of Medicine", "subitem_publisher_language": "en"}]}, "item_9_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/852.html", "subitem_relation_type_select": "URI"}}]}, "item_9_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International", "subitem_rights_language": "en", "subitem_rights_resource": "http://creativecommons.org/licenses/by-nc-nd/4.0/"}]}, "item_9_source_id_7": {"attribute_name": "収録物識別子", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "PISSN"}, {"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "EISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ohashi, Toshio", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Naganawa, Shinji", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Nasu, Yusuke", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Kuno, Kayao", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Kato, Katsuhiko", "creatorNameLang": "en"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2023-05-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "09_Ohashi.pdf", "filesize": [{"value": "3.8 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_5", "mimetype": "application/pdf", "size": 3800000.0, "url": {"objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/2006268/files/09_Ohashi.pdf"}, "version_id": "84910478-9ca9-42bc-9325-e5002490266c"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "magnetic resonance imaging", "subitem_subject_scheme": "Other"}, {"subitem_subject": "gadolinium", "subitem_subject_scheme": "Other"}, {"subitem_subject": "endolymphatic hydrops", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Meniere’s disease", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Magnetic resonance imaging of endolymphatic hydrops: a comparison of methods with and without gadolinium-based contrast agent administration", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Magnetic resonance imaging of endolymphatic hydrops: a comparison of methods with and without gadolinium-based contrast agent administration", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "17", "path": ["1685060434835"], "permalink_uri": "https://doi.org/10.18999/nagjms.85.2.299", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2023-05-26"}, "publish_date": "2023-05-26", "publish_status": "0", "recid": "2006268", "relation": {}, "relation_version_is_last": true, "title": ["Magnetic resonance imaging of endolymphatic hydrops: a comparison of methods with and without gadolinium-based contrast agent administration"], "weko_shared_id": -1}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 85(2)

Magnetic resonance imaging of endolymphatic hydrops: a comparison of methods with and without gadolinium-based contrast agent administration

https://doi.org/10.18999/nagjms.85.2.299
https://doi.org/10.18999/nagjms.85.2.299
997734f4-e086-43e9-be95-c81fd1e293e9
名前 / ファイル ライセンス アクション
09_Ohashi.pdf 09_Ohashi.pdf (3.8 MB)
license.icon
Item type itemtype_ver1(1)
公開日 2023-05-26
タイトル
タイトル Magnetic resonance imaging of endolymphatic hydrops: a comparison of methods with and without gadolinium-based contrast agent administration
言語 en
著者 Ohashi, Toshio

× Ohashi, Toshio

en Ohashi, Toshio

Search repository
Naganawa, Shinji

× Naganawa, Shinji

en Naganawa, Shinji

Search repository
Nasu, Yusuke

× Nasu, Yusuke

en Nasu, Yusuke

Search repository
Kuno, Kayao

× Kuno, Kayao

en Kuno, Kayao

Search repository
Kato, Katsuhiko

× Kato, Katsuhiko

en Kato, Katsuhiko

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報Resource http://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報 Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
キーワード
主題Scheme Other
主題 magnetic resonance imaging
キーワード
主題Scheme Other
主題 gadolinium
キーワード
主題Scheme Other
主題 endolymphatic hydrops
キーワード
主題Scheme Other
主題 Meniere’s disease
内容記述
内容記述 In the evaluation of endolymphatic hydrops (EH) using magnetic resonance (MR) imaging, hybrid of reversed image of positive endolymph signal and native image of perilymph signal multiplied with heavily T2-weighted MR cisternography (HYDROPS-Mi2) imaging with the intravenous administration of a gadolinium-based contrast agent (IV-GBCA) has been utilized. Recently, MR cisternography (MRC) without GBCA has been proposed as a potential alternative method. However, the feasibility of EH evaluation by MRC without GBCA has not been established. The present study aimed to compare HYDROPS-Mi2 imaging with IV-GBCA to MRC without IV-GBCA for the evaluation of EH. In 40 ears of 20 patients with clinically suspected EH, MRC at pre-IV-GBCA and HYDROPS-Mi2 images from 4 h post-IV-GBCA were analyzed. The saccular height on the MRC (SH-MRC) was measured. The percentage of the volume of the endolymphatic space within the whole lymphatic space of the vestibule on the HYDROPS-Mi2 image (%ELvolume-HYD) was measured. The correlation between the SH-MRC and %ELvolume-HYD was calculated. The receiver operating characteristic (ROC) of the SH-MRC and %ELvolume-HYD for the clinical diagnosis of EH was evaluated. The Spearman’s rank correlation coefficient between the SH-MRC and %ELvolume-HYD was 0.102. The areas under the ROC curve were 0.570 for the SH-MRC, and 0.926 for the %ELvolume-HYD. In conclusion, there was no significant correlation between the MRC without IV-GBCA and the HYDOROPS-Mi2 with IV-GBCA in the evaluation of EH.
言語 en
内容記述タイプ Abstract
内容記述
内容記述 This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/).
言語 en
内容記述タイプ Other
出版者
言語 en
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.85.2.299
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 https://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/852.html
収録物識別子
収録物識別子タイプ PISSN
収録物識別子 0027-7622
収録物識別子
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 85, 号 2, p. 299-309, 発行日 2023-05
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-26 01:05:13.188731
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3