{"_buckets": {"deposit": "f7340d82-13dc-4dfb-8464-9011362a7a96"}, "_deposit": {"created_by": 17, "id": "2007313", "owner": "17", "owners": [17], "owners_ext": {"displayname": "repository", "username": "repository"}, "pid": {"revision_id": 0, "type": "depid", "value": "2007313"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:02007313"}, "author_link": [], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_1629683748249": {"attribute_name": "日付", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2024-03-20", "subitem_date_issued_type": "Available"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2023-03-20", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageStart": "123702", "bibliographicVolumeNumber": "122", "bibliographic_titles": [{"bibliographic_title": "Applied Physics Letters", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "In conventional phase-contrast imaging methods, an optimum distance that is essential for x-ray interference and wavefront separation must be maintained between the object and the x-ray detector. This distance determines the apparent focal size of the x-ray source and affects spatial resolution of the system. To improve the spatial resolution, we proposed a phase-contrast imaging method that eliminates the distance required for x-ray interference and wavefront separation by placing a scintillator in close contact with a Laue angle analyzer (LAA). We mathematically described the image formed by superposition of diffracted beams in two directions of LAA and introduced a method to reconstruct tomographic sections from multiple projections captured by this setup. We experimentally demonstrated the validity and the usefulness of the proposed method. Using a physical phantom, we showed that the proposed method provides higher spatial resolution than conventional x-ray dark-field imaging. The proposed method may be useful for studying and elucidating the fine 3D microanatomy and histopathology of various biological specimens.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP Publishing", "subitem_publisher_language": "en"}]}, "item_9_relation_43": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1063/5.0139199", "subitem_relation_type_select": "DOI"}}]}, "item_9_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright 2023 Author(s). Published under an exclusive license by AIP Publishing. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing.The following article appeared in (Appl. Phys. Lett. 122, 123702 (2023)) and may be found at (https://doi.org/10.1063/5.0139199).", "subitem_rights_language": "en"}]}, "item_9_source_id_7": {"attribute_name": "収録物識別子", "attribute_value_mlt": [{"subitem_source_identifier": "0003-6951", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "embargoed access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_f1cf"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sunaguchi, Naoki", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Yuasa, Tetsuya", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Shimao, Daisuke", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Ichihara, Shu", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Gupta, Rajiv", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Ando, Masami", "creatorNameLang": "en"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2024-03-20"}], "displaytype": "detail", "download_preview_message": "Download / Preview is available from 2024/3/19.", "file_order": 0, "filename": "123702_1_online.pdf", "filesize": [{"value": "2.3 MB"}], "format": "application/pdf", "future_date_message": "Download is available from 2024/3/19.", "is_thumbnail": false, "mimetype": "application/pdf", "size": 2300000.0, "url": {"objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/2007313/files/123702_1_online.pdf"}, "version_id": "683dcd2a-bb3b-4a2e-8f1d-5a8165b5926e"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Superimposed wavefront imaging of diffraction-enhanced x-rays: A method to achieve higher resolution in crystal analyzer-based x-ray phase-contrast imaging", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Superimposed wavefront imaging of diffraction-enhanced x-rays: A method to achieve higher resolution in crystal analyzer-based x-ray phase-contrast imaging", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "17", "path": ["501"], "permalink_uri": "http://hdl.handle.net/2237/0002007313", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2023-09-13"}, "publish_date": "2023-09-13", "publish_status": "0", "recid": "2007313", "relation": {}, "relation_version_is_last": true, "title": ["Superimposed wavefront imaging of diffraction-enhanced x-rays: A method to achieve higher resolution in crystal analyzer-based x-ray phase-contrast imaging"], "weko_shared_id": -1}
Superimposed wavefront imaging of diffraction-enhanced x-rays: A method to achieve higher resolution in crystal analyzer-based x-ray phase-contrast imaging
http://hdl.handle.net/2237/0002007313
http://hdl.handle.net/2237/0002007313