WEKO3
アイテム
Assessment of endovascular coil configuration for embolization of intracranial aneurysms using computational fluid dynamics
https://doi.org/10.18999/nagjms.77.3.383
https://doi.org/10.18999/nagjms.77.3.3837bf749a0-a0dc-4417-a6e5-d72bae0ea595
名前 / ファイル | ライセンス | アクション |
---|---|---|
17_Ohshima.pdf (512.6 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-09-07 | |||||
タイトル | ||||||
タイトル | Assessment of endovascular coil configuration for embolization of intracranial aneurysms using computational fluid dynamics | |||||
言語 | en | |||||
著者 |
Ohshima, Tomotaka
× Ohshima, Tomotaka× Miyachi, Shigeru× Takahashi, Ichiro× Ishii, Katsuya |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | coil embolization | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | computational fluid dynamics | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | intracranial aneurysms | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Endovascular coil embolization of arterial aneurysms is often complicated by reduced blood flow to branching arteries. To determine the optimal coil configuration for safe embolization of endovascular aneurysms without compromising blood flow in branching arteries. A 3-dimensional voxel model, built based on an unruptured vertebral artery–posterior inferior cerebellar artery (VA–PICA) aneurysm, predicted to show impairment of flow in the PICA during endovascular coil embolization (Case 0). Six different models of final coil configuration were generated and applied to this aneurysm. Case 1 was a round coil mass. Case 2 was designed with a stent assist. Cases 3, and 4 were designed with a neck remnant and Cases 5 and 6 incorporated a balloon neck remodeling technique. Computational fluid dynamics was used to analyze the flow in the PICA in each model. The average outflow to the PICA was highest in Case 0 and lowest in Case 2 (in descending order, Case 0, 5, 4, 6, 1, 3, and 2). There was better preservation of outflow to the PICA in the balloon neck remodeling models than in the neck remnant models. In a model of endovascular coil embolization, we found considerable differences in outflow to the branching artery with small changes in coil configuration. Careful preoperative planning is important to minimize the risk of thromboembolic events during and after endovascular coil embolization. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.77.3.383 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/773.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 77, 号 3, p. 383-388, 発行日 2015-08 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/22984 | |||||
識別子タイプ | HDL |