ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C100 医学部/医学系研究科
  2. C100b 刊行物
  3. Nagoya journal of medical science
  4. 77(3)

Assessment of endovascular coil configuration for embolization of intracranial aneurysms using computational fluid dynamics

https://doi.org/10.18999/nagjms.77.3.383
https://doi.org/10.18999/nagjms.77.3.383
7bf749a0-a0dc-4417-a6e5-d72bae0ea595
名前 / ファイル ライセンス アクション
17_Ohshima.pdf 17_Ohshima.pdf (512.6 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2015-09-07
タイトル
タイトル Assessment of endovascular coil configuration for embolization of intracranial aneurysms using computational fluid dynamics
言語 en
著者 Ohshima, Tomotaka

× Ohshima, Tomotaka

WEKO 60389

en Ohshima, Tomotaka

Search repository
Miyachi, Shigeru

× Miyachi, Shigeru

WEKO 60390

en Miyachi, Shigeru

Search repository
Takahashi, Ichiro

× Takahashi, Ichiro

WEKO 60391

en Takahashi, Ichiro

Search repository
Ishii, Katsuya

× Ishii, Katsuya

WEKO 60392

en Ishii, Katsuya

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
キーワード
主題Scheme Other
主題 coil embolization
キーワード
主題Scheme Other
主題 computational fluid dynamics
キーワード
主題Scheme Other
主題 intracranial aneurysms
抄録
内容記述タイプ Abstract
内容記述 Endovascular coil embolization of arterial aneurysms is often complicated by reduced blood flow to branching arteries. To determine the optimal coil configuration for safe embolization of endovascular aneurysms without compromising blood flow in branching arteries. A 3-dimensional voxel model, built based on an unruptured vertebral artery–posterior inferior cerebellar artery (VA–PICA) aneurysm, predicted to show impairment of flow in the PICA during endovascular coil embolization (Case 0). Six different models of final coil configuration were generated and applied to this aneurysm. Case 1 was a round coil mass. Case 2 was designed with a stent assist. Cases 3, and 4 were designed with a neck remnant and Cases 5 and 6 incorporated a balloon neck remodeling technique. Computational fluid dynamics was used to analyze the flow in the PICA in each model. The average outflow to the PICA was highest in Case 0 and lowest in Case 2 (in descending order, Case 0, 5, 4, 6, 1, 3, and 2). There was better preservation of outflow to the PICA in the balloon neck remodeling models than in the neck remnant models. In a model of endovascular coil embolization, we found considerable differences in outflow to the branching artery with small changes in coil configuration. Careful preoperative planning is important to minimize the risk of thromboembolic events during and after endovascular coil embolization.
言語 en
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語 en
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.77.3.383
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/773.html
ISSN(print)
収録物識別子タイプ PISSN
収録物識別子 0027-7622
ISSN(Online)
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 77, 号 3, p. 383-388, 発行日 2015-08
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/22984
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 15:38:21.313551
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3