WEKO3
アイテム
Controlling the particle cut size of a dry cyclone using acetone
http://hdl.handle.net/2237/26588
http://hdl.handle.net/2237/265888d3fe2d1-951c-4809-9509-3f1b5d2c4bee
名前 / ファイル | ライセンス | アクション |
---|---|---|
manuscript20160127.pdf ファイル公開:2018/01/01 (384.5 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-06-07 | |||||
タイトル | ||||||
タイトル | Controlling the particle cut size of a dry cyclone using acetone | |||||
言語 | en | |||||
著者 |
Yamamoto, Tetsuya
× Yamamoto, Tetsuya× Higashino, Motoharu |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | This is an Accepted Manuscript of an article published by Taylor & Francis Group in Particulate Science and Technology: An International Journal on 2017, available online: http://www.tandfonline.com/10.1080/02726351.2016.1150370 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Acetone | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | AFM | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | classification | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cut size | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cyclone | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this study, we investigated the interaction between particles and the wall in the presence of mist to improve the particle classification performance of a dry cyclone. The interaction between a silica particle and a mica surface in the presence of a flowing acetone mist was measured by performing atomic force microscopy (AFM), which showed that an attractive force was generated and became stronger as time passed while acetone mist was supplied to the system, probably because of static electricity. In a dry cyclone system, this attractive force could enhance the classification performance. In particular, when acetone mist was supplied into the cyclone from the upper part of the dust box at higher flow rates, the classification performance was enhanced. Because acetone is highly volatile and has a low viscosity, the classification performance was improved by the evaporated acetone even when a cyclone with a dust box filled with acetone was used instead of a nozzle supplying the mist. In this case, the ratio of the mass of the particles collected by the upper part of the cyclone to the total mass of the feed powder was increased, probably because of the attractive force between the silica particles and the wall of the cyclone. Moreover, the cut size of the dry cyclone could be controlled by changing the amount of acetone in the dust box of the cyclone. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Taylor & Francis | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1080/02726351.2016.1150370 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0272-6351 | |||||
書誌情報 |
en : Particulate Science and Technology: An International Journal 巻 35, 号 2, p. 214-218, 発行日 2017 |
|||||
著者版フラグ | ||||||
値 | author | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/26588 | |||||
識別子タイプ | HDL |