Responsiveness to bronchodilator procaterol in COPD as assessed by forced oscillation technique

http://hdl.handle.net/2237/26874
http://hdl.handle.net/2237/26874
9775144f-4255-472c-8ce2-7718d29b14f3
名前 / ファイル ライセンス アクション
RESPNB_2017_Ito_for_NU_Library_08-02-2017.pdf RESPNB_2017_Ito_for_NU_Library_08-02-2017.pdf ファイル公開:2018/06/01 (894.6 kB)
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2017-08-03
タイトル
タイトル Responsiveness to bronchodilator procaterol in COPD as assessed by forced oscillation technique
言語 en
著者 Ito, Satoru

× Ito, Satoru

WEKO 73054

en Ito, Satoru

Search repository
Uchida, Akemi

× Uchida, Akemi

WEKO 73055

en Uchida, Akemi

Search repository
Isobe, Yoshitaka

× Isobe, Yoshitaka

WEKO 73056

en Isobe, Yoshitaka

Search repository
Hasegawa, Yoshinori

× Hasegawa, Yoshinori

WEKO 73057

en Hasegawa, Yoshinori

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報 © 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
言語 en
キーワード
主題Scheme Other
主題 Airway
キーワード
主題Scheme Other
主題 Airway smooth muscle
キーワード
主題Scheme Other
主題 Forced oscillation technique
キーワード
主題Scheme Other
主題 Impedance
キーワード
主題Scheme Other
主題 Bronchodilator
キーワード
主題Scheme Other
主題 Procaterol
抄録
内容記述タイプ Abstract
内容記述 The aim of this retrospective study was to assess responses to a bronchodilator by forced oscillation technique (FOT) and to relate the results of respiratory impedance (Zrs) to spirometric parameters in patients with chronic obstructive pulmonary disease (COPD). Zrs was measured as a function of frequency from 4 to 36 Hz before and after inhalation of procaterol, a short-acting β2-agonist (n = 60). Respiratory resistance (Rrs) and reactance (Xrs) were significantly frequency-dependent, and inspiratory and expiratory phases were different both before and after procaterol inhalation. The Rrs at 4 Hz and Xrs at 4–20 Hz during a whole breath were significantly improved after procaterol inhalation. The response to procaterol inhalation varied among patients, and changes in Xrs at 4 Hz significantly correlated with% change in forced expiratory volume in one second and changes in forced vital capacity. Taken together, Zrs, and specifically Xrs parameters, are sensitive to acute physiological responses to a bronchodilator in COPD.
言語 en
出版者
出版者 Elsevier
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.resp.2017.02.012
ISSN
収録物識別子タイプ PISSN
収録物識別子 1569-9048
書誌情報 en : Respiratory Physiology & Neurobiology

巻 240, p. 41-47, 発行日 2017-06
著者版フラグ
値 author
URI
識別子 https://doi.org/10.1016/j.resp.2017.02.012
識別子タイプ DOI
URI
識別子 http://hdl.handle.net/2237/26874
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 13:57:18.617527
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3