ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C100 医学部/医学系研究科
  2. C100b 刊行物
  3. Nagoya journal of medical science
  4. 79(3)

Experimental evaluation and training of stent clot retrieval : the confront clot scrambling method

https://doi.org/10.18999/nagjms.79.3.401
https://doi.org/10.18999/nagjms.79.3.401
b2e9c671-7030-4493-95d4-4c8f5809412a
名前 / ファイル ライセンス アクション
12_Ohshima.pdf 12_Ohshima.pdf (1.2 MB)
license.icon
アイテムタイプ 紀要論文 / Departmental Bulletin Paper(1)
公開日 2017-08-24
タイトル
タイトル Experimental evaluation and training of stent clot retrieval : the confront clot scrambling method
言語 en
著者 Ohshima, Tomotaka

× Ohshima, Tomotaka

WEKO 73270

en Ohshima, Tomotaka

Search repository
Goto, Shunsaku

× Goto, Shunsaku

WEKO 73271

en Goto, Shunsaku

Search repository
Yamamoto, Taiki

× Yamamoto, Taiki

WEKO 73272

en Yamamoto, Taiki

Search repository
Ishikawa, Kojiro

× Ishikawa, Kojiro

WEKO 73273

en Ishikawa, Kojiro

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報Resource http://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報 Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
言語 en
キーワード
主題Scheme Other
主題 acute ischemic stroke
キーワード
主題Scheme Other
主題 endovascular treatment
キーワード
主題Scheme Other
主題 experiment
キーワード
主題Scheme Other
主題 stent clot retriever
抄録
内容記述タイプ Abstract
内容記述 The introduction of stent retrievers has changed the methods used for acute intracranial thrombectomy, but the training approach has not been discussed enough. We, therefore, aimed to establish a simple skill up method which can be used to train anytime and anywhere with low costs. Also, we introduce our experimental confront clot scrambling method (CCSM) which makes a profitable visualization in how the stent retriever works. The CCSM involved a sham clot set in the middle of a polyvinyl chloride tube, after which two stent retrievers were navigated from each side before being simultaneously withdrawn with the same force. The stent that removes the sham clot is determined to have stronger clot retrieval ability. Several adjunctive techniques were also compared. The push and fluff adjunctive technique was the most effective among all the stents. Generally, the former deployed stent was stronger than later one. Therefore, the later deployed stent with the push and fluff technique lets us know whether the physician’s maneuver worked well or not. CCSM could directly evaluate the ability of adjunctive techniques with each stent retriever and demonstrate the physicians’ skills. Because the actual endovascular clot retrieval requires extreme fine maneuvers against invisible vessels, repeat training is very important especially in beginners.
言語 en
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語 en
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.79.3.401
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/793.html
ISSN(print)
収録物識別子タイプ PISSN
収録物識別子 0027-7622
ISSN(Online)
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 79, 号 3, p. 401-406, 発行日 2017-08
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/26917
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 13:56:14.544425
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3