8-F balloon guide catheter for embolization of anterior circulation aneurysms : an institutional experience in 152 patients
https://doi.org/10.18999/nagjms.79.4.435
https://doi.org/10.18999/nagjms.79.4.43548a4e975-1b62-4b8f-8a12-e6fa62e191ff
名前 / ファイル | ライセンス | アクション |
---|---|---|
02_Ohshima.pdf (9.9 MB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-22 | |||||
タイトル | ||||||
タイトル | 8-F balloon guide catheter for embolization of anterior circulation aneurysms : an institutional experience in 152 patients | |||||
言語 | en | |||||
著者 |
Ohshima, Tomotaka
× Ohshima, Tomotaka× Dash, Chinmaya× Belayev, Andrey× Yamamoto, Taiki× Goto, Shunsaku× Kato, Yoko |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報Resource | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |||||
権利情報 | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | balloon guide catheter | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | coil embolization | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | intracranial aneurysms | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The use of 8-F balloon guide catheter (BGC) for proximal flow control was previously shown to prevent distal embolic complications during mechanical clot retrieval in patients with acute ischemic stroke. In this retrospective study, the utility of 8-F BGCs for proximal flow control during endovascular coiling of anterior circulation aneurysms was investigated. Patients who underwent endovascular coiling for anterior circulation aneurysms between August 2013 and December 2016 were retrospectively analyzed. Among a total of 152 patients included in this series, 64 patients presented with aneurysmal rupture, whereas the aneurysms were detected incidentally or due to mass effects in the remaining patients. 8-F BGCs were successfully navigated in all patients. The balloon was inflated during navigation in 19 patients. Inflation of the catheter balloon during coil embolization was required in 34 patients; this was performed as an emergency maneuver in six of these patients. Thromboembolic complications occurred in one patient. 8-F BGC can be effectively used for proximal flow control during endovascular treatment of anterior circulation aneurysms. The other advantages included improved navigation of tortuous arterial anatomy, coil stabilization during aneurysmal coiling, and freedom to utilize aneurysmal neck-remodeling balloons for additional adjunctive techniques or to deploy rescue stents. This novel approach might be safely and effectively used in patients undergoing endovascular treatment for anterior circulation aneurysms. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.79.4.435 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/794.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 79, 号 4, p. 435-441, 発行日 2017-11 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/27112 | |||||
識別子タイプ | HDL |