Feasibility of the unilateral-flange stent for the treatment of benign pancreatic duct stricture : a pilot study

https://doi.org/10.18999/nagjms.79.4.453
https://doi.org/10.18999/nagjms.79.4.453
753fcfb8-c0b7-4b3d-bf98-8b29e2482228
名前 / ファイル ライセンス アクション
04_Bhanthumkomol.pdf 04_Bhanthumkomol.pdf (2.6 MB)
license.icon
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2017-11-22
タイトル
タイトル Feasibility of the unilateral-flange stent for the treatment of benign pancreatic duct stricture : a pilot study
言語 en
著者 Bhanthumkomol, Patommatat

× Bhanthumkomol, Patommatat

WEKO 74096

en Bhanthumkomol, Patommatat

Search repository
Hara, Kazuo

× Hara, Kazuo

WEKO 74097

en Hara, Kazuo

Search repository
Mizuno, Nobumasa

× Mizuno, Nobumasa

WEKO 74098

en Mizuno, Nobumasa

Search repository
Hijioka, Susumu

× Hijioka, Susumu

WEKO 74099

en Hijioka, Susumu

Search repository
Okuno, Nozomi

× Okuno, Nozomi

WEKO 74100

en Okuno, Nozomi

Search repository
Yoshida, Tsukasa

× Yoshida, Tsukasa

WEKO 74101

en Yoshida, Tsukasa

Search repository
Tokuhisa, Junya

× Tokuhisa, Junya

WEKO 74102

en Tokuhisa, Junya

Search repository
Siramolpiwat, Sith

× Siramolpiwat, Sith

WEKO 74103

en Siramolpiwat, Sith

Search repository
Vilaichone, Ratha-korn

× Vilaichone, Ratha-korn

WEKO 74104

en Vilaichone, Ratha-korn

Search repository
Pornthisarn, Bubpha

× Pornthisarn, Bubpha

WEKO 74105

en Pornthisarn, Bubpha

Search repository
Niwa, Yasumasa

× Niwa, Yasumasa

WEKO 74106

en Niwa, Yasumasa

Search repository
Tajika, Masahiro

× Tajika, Masahiro

WEKO 74107

en Tajika, Masahiro

Search repository
Tanaka, Tsutomu

× Tanaka, Tsutomu

WEKO 74108

en Tanaka, Tsutomu

Search repository
Ishihara, Makoto

× Ishihara, Makoto

WEKO 74109

en Ishihara, Makoto

Search repository
Hirayama, Yutaka

× Hirayama, Yutaka

WEKO 74110

en Hirayama, Yutaka

Search repository
Yamao, Kenji

× Yamao, Kenji

WEKO 74111

en Yamao, Kenji

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報Resource http://creativecommons.org/licenses/by-nc-nd/4.0/
権利情報 Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
キーワード
主題Scheme Other
主題 stents
キーワード
主題Scheme Other
主題 pancreatic ducts
キーワード
主題Scheme Other
主題 chronic pancreatitis
キーワード
主題Scheme Other
主題 stricture
キーワード
主題Scheme Other
主題 endoscopic retrograde cholangiopancreatography
抄録
内容記述タイプ Abstract
内容記述 Endoscopic placement of the plastic stent has been adopted as an initial treatment for chronic pancreatitis with pancreatic duct stricture. Stent fracture while attempting removal is one of the complications of stent exchange. The use of the unilateral-flange stent in these patients has never been reported. We investigated the outcomes associated with the use of this stent with regard to stent exchange and stent-related adverse events. From 2011 to 2015, 9 patients with chronic pancreatitis and main pancreatic duct (MPD) stricture treated with the unilateral-flange stent were included. Eleven endoscopic treatment sessions, 53 endoscopic stent deployments or exchange procedures were analyzed. Technical success rate was 100%. Forty-eight stents were exchanged on a regular basis in 1 to 6-month intervals. Another 5 stent exchange procedures were urgently performed due to stent obstruction and caused pancreatitis (n=2), symptomatic external stent migration (n=2), and concurrent cholangitis (n=1). The rate of symptomatic migration was 3.7%. The mean duration for stent exchange was 29 minutes and no stent fracture occurred during the procedure. Of 11 endoscopic treatment sessions, 7 were successful, 3 were changed to the metallic stents, and 1 was lost to follow-up. According to this study, unilateral-flange stent placement for benign MPD stricture is technically feasible and effective. Stent removal during the exchange period is unchallenging and without stent fracture.
言語 en
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語 en
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ID登録
ID登録 10.18999/nagjms.79.4.453
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/794.html
ISSN(print)
収録物識別子タイプ PISSN
収録物識別子 0027-7622
ISSN(Online)
収録物識別子タイプ EISSN
収録物識別子 2186-3326
書誌情報 en : Nagoya Journal of Medical Science

巻 79, 号 4, p. 453-458, 発行日 2017-11
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/27114
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 13:50:53.668801
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3