WEKO3
アイテム
{"_buckets": {"deposit": "504350fc-333d-44d8-bc14-6630710b7a90"}, "_deposit": {"id": "24895", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "24895"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00024895", "sets": ["2043"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "466", "bibliographicPageStart": "459", "bibliographicVolumeNumber": "79", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A retrospective study was performed to examine the efficacy of intraoperative monitoring of the external anal sphincter (EAS) muscle-evoked potential after a transcranial muscle-action potential (Tc-MsEP) in spinal cord surgery, and to evaluate alarm points for EAS waveform deterioration related to postoperative bowel bladder disorder (BBD). BBD is caused by damage to the hypogastric, pelvic, and pudendal nerves and leads to a significant reduction in quality of life. Intraoperative Tc-MsEP monitoring using the EAS is common to prevent neurological deficit, but the relationship of BBD with intraoperative monitoring of the EAS has not been examined. Waveform derivation from the EAS using a plug-type surface electrode was investigated in 123 spine surgeries in which Tc-MsEP was recorded intraoperatively outside the anal sphincter. An acceptable baseline waveform from the EAS was detected in 105 of the 123 cases (85.3%). Preoperative BBD was present in 16 cases, postoperative BBD occurred in 8 cases, and intraoperative waveform deterioration from the EAS was detected in 25 cases. The derivation rate was significantly lower in cases with preoperative BBD compared to those without BBD (62.5% vs. 88.9%, p\u003c0.01). Waveform deterioration from the EAS had a sensitivity of 100%, specificity of 93.0%, positive predictive value of 50%, and negative predictive value of 100% for detection of postoperative BBD. All postoperative BBD was detected with an EAS amplitude decrease to \u003c30% of baseline. Therefore, in spine surgery, a Tc-MsEP intraoperative EAS amplitude decrease to \u003c30% of the control waveform may be useful for prediction of postoperative BBD.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/794.html"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/27115"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.79.4.459", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University Graduate School of Medicine, School of Medicine"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kobayashi, Kazuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "74112", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ando, Kei"}], "nameIdentifiers": [{"nameIdentifier": "74113", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yagi, Hideki"}], "nameIdentifiers": [{"nameIdentifier": "74114", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ito, Kenyu"}], "nameIdentifiers": [{"nameIdentifier": "74115", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsushima, Mikito"}], "nameIdentifiers": [{"nameIdentifier": "74116", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Morozumi, Masayoshi"}], "nameIdentifiers": [{"nameIdentifier": "74117", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanaka, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "74118", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Machino, Masaaki"}], "nameIdentifiers": [{"nameIdentifier": "74119", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ota, Kyotaro"}], "nameIdentifiers": [{"nameIdentifier": "74120", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuyama, Yukihiro"}], "nameIdentifiers": [{"nameIdentifier": "74121", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishiguro, Naoki"}], "nameIdentifiers": [{"nameIdentifier": "74122", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Imagama, Shiro"}], "nameIdentifiers": [{"nameIdentifier": "74123", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "05_Kobayashi.pdf", "filesize": [{"value": "9.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 9900000.0, "url": {"label": "05_Kobayashi.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/24895/files/05_Kobayashi.pdf"}, "version_id": "74fdbed4-69e0-4ef7-bd9c-692cdbf31e7d"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "external anal sphincter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "intraoperative spinal cord monitoring", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Tc-MsEP", "subitem_subject_scheme": "Other"}, {"subitem_subject": "bowel bladder disorder", "subitem_subject_scheme": "Other"}, {"subitem_subject": "spinal surgery", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Prevention and prediction of postoperative bowel bladder disorder using an anal plug electrode with Tc-MsEP monitoring during spine surgery", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Prevention and prediction of postoperative bowel bladder disorder using an anal plug electrode with Tc-MsEP monitoring during spine surgery"}]}, "item_type_id": "9", "owner": "1", "path": ["2043"], "permalink_uri": "https://doi.org/10.18999/nagjms.79.4.459", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-11-22"}, "publish_date": "2017-11-22", "publish_status": "0", "recid": "24895", "relation": {}, "relation_version_is_last": true, "title": ["Prevention and prediction of postoperative bowel bladder disorder using an anal plug electrode with Tc-MsEP monitoring during spine surgery"], "weko_shared_id": null}
Prevention and prediction of postoperative bowel bladder disorder using an anal plug electrode with Tc-MsEP monitoring during spine surgery
https://doi.org/10.18999/nagjms.79.4.459
https://doi.org/10.18999/nagjms.79.4.4599fbb46eb-31c4-48b3-9136-9b11fefac4d1
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-22 | |||||
タイトル | ||||||
タイトル | Prevention and prediction of postoperative bowel bladder disorder using an anal plug electrode with Tc-MsEP monitoring during spine surgery | |||||
著者 |
Kobayashi, Kazuyoshi
× Kobayashi, Kazuyoshi× Ando, Kei× Yagi, Hideki× Ito, Kenyu× Tsushima, Mikito× Morozumi, Masayoshi× Tanaka, Satoshi× Machino, Masaaki× Ota, Kyotaro× Matsuyama, Yukihiro× Ishiguro, Naoki× Imagama, Shiro |
|||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | external anal sphincter | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | intraoperative spinal cord monitoring | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Tc-MsEP | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | bowel bladder disorder | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | spinal surgery | |||||
抄録 | ||||||
内容記述 | A retrospective study was performed to examine the efficacy of intraoperative monitoring of the external anal sphincter (EAS) muscle-evoked potential after a transcranial muscle-action potential (Tc-MsEP) in spinal cord surgery, and to evaluate alarm points for EAS waveform deterioration related to postoperative bowel bladder disorder (BBD). BBD is caused by damage to the hypogastric, pelvic, and pudendal nerves and leads to a significant reduction in quality of life. Intraoperative Tc-MsEP monitoring using the EAS is common to prevent neurological deficit, but the relationship of BBD with intraoperative monitoring of the EAS has not been examined. Waveform derivation from the EAS using a plug-type surface electrode was investigated in 123 spine surgeries in which Tc-MsEP was recorded intraoperatively outside the anal sphincter. An acceptable baseline waveform from the EAS was detected in 105 of the 123 cases (85.3%). Preoperative BBD was present in 16 cases, postoperative BBD occurred in 8 cases, and intraoperative waveform deterioration from the EAS was detected in 25 cases. The derivation rate was significantly lower in cases with preoperative BBD compared to those without BBD (62.5% vs. 88.9%, p<0.01). Waveform deterioration from the EAS had a sensitivity of 100%, specificity of 93.0%, positive predictive value of 50%, and negative predictive value of 100% for detection of postoperative BBD. All postoperative BBD was detected with an EAS amplitude decrease to <30% of baseline. Therefore, in spine surgery, a Tc-MsEP intraoperative EAS amplitude decrease to <30% of the control waveform may be useful for prediction of postoperative BBD. | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.79.4.459 | |||||
ID登録タイプ | JaLC | |||||
ISSN(print) | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0027-7622 | |||||
書誌情報 |
Nagoya Journal of Medical Science 巻 79, 号 4, p. 459-466, 発行日 2017-11 |
|||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/794.html | |||||
識別子タイプ | URI | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/27115 | |||||
識別子タイプ | HDL |