ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "9936d755-d208-4a32-8077-8e678ebb2f1a"}, "_deposit": {"id": "24900", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "24900"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00024900", "sets": ["2043"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "513", "bibliographicPageStart": "505", "bibliographicVolumeNumber": "79", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Despite major developments in treating intracranial aneurysms by endovascular coil embolization, complete occlusion of the entire aneurysmal neck remains a problem. We present a novel endovascular strategy for middle- and large sized aneurysms called the “hemispheric divided coiling technique” and compare the short-term follow-up results of this technique with those of conventional coil embolization. Ten patients (mean age, 69.7 ± 9.7 years) with middle- or large-sized ruptured or unruptured intracranial aneurysms (mean maximum aneurysmal diameter, 12.09 ± 3.6 mm) were treated by the hemispheric divided coiling technique, in combination with various adjunctive techniques. We compared the initial occlusion grade, volume embolization ratio, and recurrence rate in this group of patients (hemispheric group) with the results from 20 previous cases (conventional group: mean age, 62.8 ± 9.8 years; mean maximum aneurysmal diameter, 11.43 ± 3.5 mm). The mean volume embolization ratio of the hemispheric group was significantly higher than that of the conventional group (42.3% vs. 31.1%). The hemispheric divided coiling technique achieved a high volume embolization ratio for middle- and large sized intracranial aneurysms, with a low recurrence rate.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/794.html"}, {"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/27120"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.79.4.505", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University Graduate School of Medicine, School of Medicine"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ohshima, Tomotaka"}], "nameIdentifiers": [{"nameIdentifier": "74145", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Goto, Shunsaku"}], "nameIdentifiers": [{"nameIdentifier": "74146", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamamoto, Taiki"}], "nameIdentifiers": [{"nameIdentifier": "74147", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishikawa, Kojiro"}], "nameIdentifiers": [{"nameIdentifier": "74148", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "10_Ohshima.pdf", "filesize": [{"value": "2.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2200000.0, "url": {"label": "10_Ohshima.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/24900/files/10_Ohshima.pdf"}, "version_id": "f95cbc86-e3c0-47ec-b57a-5685404639f7"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "coil embolization", "subitem_subject_scheme": "Other"}, {"subitem_subject": "endovascular treatment", "subitem_subject_scheme": "Other"}, {"subitem_subject": "intracranial aneurysms", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms"}]}, "item_type_id": "9", "owner": "1", "path": ["2043"], "permalink_uri": "https://doi.org/10.18999/nagjms.79.4.505", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-11-22"}, "publish_date": "2017-11-22", "publish_status": "0", "recid": "24900", "relation": {}, "relation_version_is_last": true, "title": ["Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms"], "weko_shared_id": null}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 79(4)

Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms

https://doi.org/10.18999/nagjms.79.4.505
https://doi.org/10.18999/nagjms.79.4.505
96616db2-6e62-47f4-aaf7-0e985456a598
名前 / ファイル ライセンス アクション
10_Ohshima.pdf 10_Ohshima.pdf (2.2 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2017-11-22
タイトル
タイトル Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms
著者 Ohshima, Tomotaka

× Ohshima, Tomotaka

WEKO 74145

Ohshima, Tomotaka

Search repository
Goto, Shunsaku

× Goto, Shunsaku

WEKO 74146

Goto, Shunsaku

Search repository
Yamamoto, Taiki

× Yamamoto, Taiki

WEKO 74147

Yamamoto, Taiki

Search repository
Ishikawa, Kojiro

× Ishikawa, Kojiro

WEKO 74148

Ishikawa, Kojiro

Search repository
キーワード
主題Scheme Other
主題 coil embolization
キーワード
主題Scheme Other
主題 endovascular treatment
キーワード
主題Scheme Other
主題 intracranial aneurysms
抄録
内容記述 Despite major developments in treating intracranial aneurysms by endovascular coil embolization, complete occlusion of the entire aneurysmal neck remains a problem. We present a novel endovascular strategy for middle- and large sized aneurysms called the “hemispheric divided coiling technique” and compare the short-term follow-up results of this technique with those of conventional coil embolization. Ten patients (mean age, 69.7 ± 9.7 years) with middle- or large-sized ruptured or unruptured intracranial aneurysms (mean maximum aneurysmal diameter, 12.09 ± 3.6 mm) were treated by the hemispheric divided coiling technique, in combination with various adjunctive techniques. We compared the initial occlusion grade, volume embolization ratio, and recurrence rate in this group of patients (hemispheric group) with the results from 20 previous cases (conventional group: mean age, 62.8 ± 9.8 years; mean maximum aneurysmal diameter, 11.43 ± 3.5 mm). The mean volume embolization ratio of the hemispheric group was significantly higher than that of the conventional group (42.3% vs. 31.1%). The hemispheric divided coiling technique achieved a high volume embolization ratio for middle- and large sized intracranial aneurysms, with a low recurrence rate.
内容記述タイプ Abstract
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/nagjms.79.4.505
ID登録タイプ JaLC
ISSN(print)
収録物識別子タイプ ISSN
収録物識別子 0027-7622
書誌情報 Nagoya Journal of Medical Science

巻 79, 号 4, p. 505-513, 発行日 2017-11
著者版フラグ
値 publisher
URI
識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/794.html
識別子タイプ URI
URI
識別子 http://hdl.handle.net/2237/27120
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 13:50:47.144386
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3