Head-to-head comparison of acute and chronic pulmonary vein stenosis for cryoballoon versus radiofrequency ablation
http://hdl.handle.net/2237/00028493
http://hdl.handle.net/2237/00028493ee2cbc2f-17f4-4446-95b4-d9ecee331485
名前 / ファイル | ライセンス | アクション |
---|---|---|
R2 (1.5 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-08-20 | |||||
タイトル | ||||||
タイトル | Head-to-head comparison of acute and chronic pulmonary vein stenosis for cryoballoon versus radiofrequency ablation | |||||
言語 | en | |||||
著者 |
Watanabe, Ryo
× Watanabe, Ryo× Sairaku, Akinori× Yoshida, Yukihiko× Nanasato, Mamoru× Kamiya, Hiroki× Suzuki, Hirohiko× Ogura, Yasuhiro× Aoyama, Yutaka× Maeda, Mayuho× Ando, Monami× Eguchi, Shunsuke× Inden, Yasuya× Kihara, Yasuki× Murohara, Toyoaki |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | This is the peer reviewed version of the following article: [Watanabe R, Sairaku A, Yoshida Y, et al. Head‐to‐head comparison of acute and chronic pulmonary vein stenosis for cryoballoon versus radiofrequency ablation. Pacing Clin Electrophysiol. 2018;41:376–382. https://doi.org/10.1111/pace.13293], which has been published in final form at [https://doi.org/10.1111/pace.13293]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | acute narrowing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | atrial fibrillation ablation | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | cryoballoon | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | pulmonary vein stenosis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | radiofrequency | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 1 Background: Cryoballoon (CB) applications to pulmonary veins (PVs) can cause stenosis just as radiofrequency (RF) energy deliveries. The goal of the present study was to clarify whether or not there was any difference in the extent of acute or chronic PV narrowing after PV isolation between the two different energy sources. 2 Methods: Consecutive patients with paroxysmal atrial fibrillation who were scheduled to undergo a PV isolation were randomized 1:1 to receive CB or RF ablation. The endpoints were any acute PV narrowing assessed with the use of intracardiac ultrasound during the procedure and PV stenosis measured with cardiac computed tomography at the 3‐month follow‐up. 3 Results: An acute reduction in the luminal area of the left superior PV (mean ± standard deviation, –6.8 ± 8.7 vs –19.9 ± 14.7%; P < 0.001) and left inferior PV (–5.1 ± 20.2 vs –15.3 ± 11.6%; P = 0.03) was significantly smaller in the CB arm (N = 25) than the RF arm (N = 25). There was no difference in the extent of PV stenosis 3 months after the ablation between the arms (0–25% stenosis, 90% vs 88%, 25–50% stenosis, 10% vs 12%, >50% stenosis, both 0%; P = 0.82). A greater acute PV narrowing was likely to lead to chronic stenosis in the RF arm (P = 0.004). 4 Conclusions: CB ablation may reduce the acute narrowing of the left‐sided PVs as compared to RF ablation. | |||||
言語 | en | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | ファイル公開:2019-04-01 | |||||
言語 | ja | |||||
出版者 | ||||||
出版者 | Wiley | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | https://doi.org/10.1111/pace.13293 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0147-8389 | |||||
書誌情報 |
en : Pacing and Clinical Electrophysiology 巻 41, 号 4, p. 376-382, 発行日 2018-04-01 |
|||||
著者版フラグ | ||||||
値 | author |