Usefulness of modified pigtail-shaped microguidewire guidance for microcatheter navigation in difficult vasculatures during neuroendovascular interventions
https://doi.org/10.18999/nagjms.80.4.551
https://doi.org/10.18999/nagjms.80.4.5512e4ac5b4-889e-4519-ac81-5cc9aa6db335
名前 / ファイル | ライセンス | アクション |
---|---|---|
11_Ohshima (5.3 MB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-01-18 | |||||
タイトル | ||||||
タイトル | Usefulness of modified pigtail-shaped microguidewire guidance for microcatheter navigation in difficult vasculatures during neuroendovascular interventions | |||||
言語 | en | |||||
著者 |
Ohshima, Tomotaka
× Ohshima, Tomotaka× Shamim Ul Haq Siddiqi× Miyachi, Shigeru× Matsuo, Naoki× Kawaguchi, Reo× Kato, Yoko× Takayasu, Masakazu |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報Resource | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |||||
権利情報 | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | catheterization | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | endovascular treatment | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | intracranial aneurysms | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | shaping | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | microguidewire | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We previously reported using a microguidewire with a curved, pigtail-shaped tip as an anchor for navigating a microcatheter. However, we considered that the microcatheter could follow even if the tip of wire did not advance so far distally. The present study assessed the usefulness of a modified version of this pigtail-shaped microguidewire for navigating microcatheters to difficult vasculatures during neurointerventions. The microguidewire was repeatedly evaluated using a silicon tube vascular model. We also employed this method as the first choice for some patients. In both the in vitro tests and clinical use, the round curved tip could be used to position the microguidewire at the entry of a sharply angled vessel or aneurysmal neck, and the following catheter could then be advanced gently and easily. This technique allowed navigation of the microcatheter without inserting the guidewire into the distal vasculature. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.80.4.551 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/804.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 80, 号 4, p. 551-557, 発行日 2018-11 |
|||||
著者版フラグ | ||||||
値 | publisher |