{"_buckets": {"deposit": "5dff4bb0-0111-422d-96d7-eed7dc936ac2"}, "_deposit": {"id": "27357", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "27357"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00027357", "sets": ["2359"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "163", "bibliographicPageStart": "159", "bibliographicVolumeNumber": "81", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The periacetabular gap is an inherent consequence of the peripheral rim press-fit of the porous tantalum acetabular component. The circumference of the prosthesis is clearly depicted with computed tomography (CT) images that have been optimised to reduce metal artefacts. This case report highlights the utility of single-energy metal artefact reduction (SEMAR) for CT evaluation of the periacetabular gap by comparing CT images with and without SEMAR. A 70-year-old woman with a 5-year history of rheumatoid arthritis underwent total hip arthroplasty with a porous tantalum modular acetabular component. A periacetabular gap was suspected by plain radiography 2 weeks postoperatively. The metal artefacts rendered evaluation of the circumference of the acetabular component difficult in CT images acquired without SEMAR. In contrast, there were fewer metal artefacts, and a periacetabular gap (depth of 6.5 mm in DeLee and Charnley zone 2) was clearly depicted in CT images with SEMAR 2 weeks postoperatively. The porous surface of the acetabular component was in contact with the anterior and posterior rims of the acetabulum. Gap filling with bone and bone ingrowth into the porous surface were observed on CT images with SEMAR 24 weeks postoperatively. In conclusion, SEMAR reduces metal artefacts and improves CT image quality around the circumference of the acetabular component. The periacetabular gap and its filling with bone are clearly depicted in CT images with SEMAR, but not without SEMAR. ", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.81.1.159", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University Graduate School of Medicine, School of Medicine"}]}, "item_9_relation_43": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/811.html ", "subitem_relation_type_select": "URI"}}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_61": {"attribute_name": "ISSN(Online)", "attribute_value_mlt": [{"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Asai, Shuji"}], "nameIdentifiers": [{"nameIdentifier": "89466", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sobue, Yasumori"}], "nameIdentifiers": [{"nameIdentifier": "89467", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Asai, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "89468", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, Nobunori"}], "nameIdentifiers": [{"nameIdentifier": "89469", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Tatsuo"}], "nameIdentifiers": [{"nameIdentifier": "89470", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Takuya"}], "nameIdentifiers": [{"nameIdentifier": "89471", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishiguro, Naoki"}], "nameIdentifiers": [{"nameIdentifier": "89472", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kojima, Toshihisa"}], "nameIdentifiers": [{"nameIdentifier": "89473", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-03-15"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "15_Asai.pdf", "filesize": [{"value": "4.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 4000000.0, "url": {"label": "15_Asai.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/27357/files/15_Asai.pdf"}, "version_id": "047c8a5e-f800-49a0-aae6-3430402d22f3"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "artefact", "subitem_subject_scheme": "Other"}, {"subitem_subject": "computed tomography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "rheumatoid arthritis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "tantalum", "subitem_subject_scheme": "Other"}, {"subitem_subject": "total hip replacement", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Computed tomography evaluation of the periacetabular gap of a porous tantalum acetabular component", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Computed tomography evaluation of the periacetabular gap of a porous tantalum acetabular component"}]}, "item_type_id": "9", "owner": "1", "path": ["2359"], "permalink_uri": "https://doi.org/10.18999/nagjms.81.1.159", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-03-15"}, "publish_date": "2019-03-15", "publish_status": "0", "recid": "27357", "relation": {}, "relation_version_is_last": true, "title": ["Computed tomography evaluation of the periacetabular gap of a porous tantalum acetabular component"], "weko_shared_id": 3}
Computed tomography evaluation of the periacetabular gap of a porous tantalum acetabular component
https://doi.org/10.18999/nagjms.81.1.159
https://doi.org/10.18999/nagjms.81.1.15975d2991f-363c-4332-9511-3fbe7b285838
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-15 | |||||
タイトル | ||||||
タイトル | Computed tomography evaluation of the periacetabular gap of a porous tantalum acetabular component | |||||
著者 |
Asai, Shuji
× Asai, Shuji× Sobue, Yasumori× Asai, Nobuyuki× Takahashi, Nobunori× Watanabe, Tatsuo× Matsumoto, Takuya× Ishiguro, Naoki× Kojima, Toshihisa |
|||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | artefact | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | computed tomography | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | rheumatoid arthritis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | tantalum | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | total hip replacement | |||||
抄録 | ||||||
内容記述 | The periacetabular gap is an inherent consequence of the peripheral rim press-fit of the porous tantalum acetabular component. The circumference of the prosthesis is clearly depicted with computed tomography (CT) images that have been optimised to reduce metal artefacts. This case report highlights the utility of single-energy metal artefact reduction (SEMAR) for CT evaluation of the periacetabular gap by comparing CT images with and without SEMAR. A 70-year-old woman with a 5-year history of rheumatoid arthritis underwent total hip arthroplasty with a porous tantalum modular acetabular component. A periacetabular gap was suspected by plain radiography 2 weeks postoperatively. The metal artefacts rendered evaluation of the circumference of the acetabular component difficult in CT images acquired without SEMAR. In contrast, there were fewer metal artefacts, and a periacetabular gap (depth of 6.5 mm in DeLee and Charnley zone 2) was clearly depicted in CT images with SEMAR 2 weeks postoperatively. The porous surface of the acetabular component was in contact with the anterior and posterior rims of the acetabulum. Gap filling with bone and bone ingrowth into the porous surface were observed on CT images with SEMAR 24 weeks postoperatively. In conclusion, SEMAR reduces metal artefacts and improves CT image quality around the circumference of the acetabular component. The periacetabular gap and its filling with bone are clearly depicted in CT images with SEMAR, but not without SEMAR. | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.81.1.159 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/811.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
Nagoya Journal of Medical Science 巻 81, 号 1, p. 159-163, 発行日 2019-02 |
|||||
著者版フラグ | ||||||
値 | publisher |