WEKO3
アイテム
MRI-guided percutaneous needle biopsy with 1.2T open MRI : study protocol for a prospective feasibility study (SCIRO-1701)
https://doi.org/10.18999/nagjms.81.3.463
https://doi.org/10.18999/nagjms.81.3.46383a462d1-f090-48b3-ad09-f2e24562973d
名前 / ファイル | ライセンス | アクション |
---|---|---|
11_Matsui.pdf (764.8 kB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-09-04 | |||||
タイトル | ||||||
タイトル | MRI-guided percutaneous needle biopsy with 1.2T open MRI : study protocol for a prospective feasibility study (SCIRO-1701) | |||||
言語 | en | |||||
著者 |
Matsui, Yusuke
× Matsui, Yusuke× Sakurai, Jun× Hiraki, Takao× Okamoto, Soichiro× Iguchi, Toshihiro× Tomita, Koji× Uka, Mayu× Gobara, Hideo× Kanazawa, Susumu |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報Resource | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |||||
権利情報 | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | magnetic resonance imaging | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | high-field | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | magnetic resonance fluoroscopy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | biopsy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | feasibility | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | There has been growing interest in magnetic resonance imaging (MRI)-guided interventional procedures such as percutaneous needle biopsy. Although open MRI is preferable for MRI-guided procedures in terms of patient accessibility, its inferior imaging capability due to lower field strength is a substantial limitation. In this situation, the high-field (1.2T) open MRI has recently become available. This novel MRI system is expected to provide excellent image quality as well as good patient accessibility, potentially contributing to safe and accurate device manipulation. This trial is designed to investigate the feasibility of MRI-guided percutaneous needle biopsy with this system. Patients with lesions needing percutaneous needle biopsy for pathological diagnosis are included. The enrollment of ten patients is intended. The primary endpoint of this study is the feasibility of biopsy needle insertion under real-time MR-fluoroscopy guidance based on the presence of the notch of the biopsy needle within the target lesion. The secondary endpoints are adverse events, device failures, and success of specimen acquisition. Once the feasibility of MRI-guided biopsy with 1.2T open MRI is validated by this study, it may potentially encourage widespread use of MRI-guidance for biopsy procedures. Furthermore, it may lead to development of the other MRI-guided interventional procedures using this MRI system. | |||||
言語 | en | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | This study is supported by a grant from the Japan Society for the Promotion of Science (JSPS KAKENHI, Grant Number 17K10438). | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.81.3.463 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/813.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 81, 号 3, p. 463-468, 発行日 2019-08 |
|||||
著者版フラグ | ||||||
値 | publisher |