{"_buckets": {"deposit": "b44a1493-50c1-4e19-b81b-38a89743bde4"}, "_deposit": {"id": "28666", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "28666"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00028666", "sets": ["675"]}, "author_link": ["94094", "94095", "94096", "94097", "94098", "94099", "94100"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "8", "bibliographicPageStart": "083511", "bibliographicVolumeNumber": "86", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific Instruments", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "For the satellite tokamak JT-60 Super Advanced (JT-60SA), a divertor Thomson scattering measurement system is planning to be installed. In this study, we improved the design of the collection optics based on the previous one, in which it was found that the solid angle of the collection optics became very small, mainly because of poor accessibility to the measurement region. By improvement, the solid angle was increased by up to approximately five times. To accurately assess the measurement performance, background noise was assessed using the plasma parameters in two typical discharges in JT-60SA calculated from the SONIC code. Moreover, the influence of the reflection of bremsstrahlung radiation by the wall is simulated by using a ray tracing simulation. The errors in the temperature and the density are assessed based on the simulation results for three typical field of views.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP Publishing", "subitem_publisher_language": "en"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1063/1.4929514", "subitem_relation_type_select": "DOI"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright 2015 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing.The following article appeared in (Review of Scientific Instruments. v.86, n.8, 2015, p.083511) and may be found at (http://dx.doi.org/10.1063/1.4929514).", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_61": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0034-6748", "subitem_source_identifier_type": "PISSN"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kajita, Shin", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "94094", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatae, Takaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "94095", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tojo, Hiroshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "94096", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Enokuchi, Akito", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "94097", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamano, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "94098", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimizu, Katsuhiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "94099", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawashima, Hisato", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "94100", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-11-07"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "1_4929514.pdf", "filesize": [{"value": "2.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 2600000.0, "url": {"label": "1_4929514", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/28666/files/1_4929514.pdf"}, "version_id": "f7118593-2281-48e1-86b2-a8512690a943"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Performance of JT-60SA divertor Thomson scattering diagnostics", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Performance of JT-60SA divertor Thomson scattering diagnostics", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["675"], "permalink_uri": "http://hdl.handle.net/2237/00030855", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2019-11-07"}, "publish_date": "2019-11-07", "publish_status": "0", "recid": "28666", "relation": {}, "relation_version_is_last": true, "title": ["Performance of JT-60SA divertor Thomson scattering diagnostics"], "weko_shared_id": -1}
  1. F200 未来材料・システム研究所
  2. F200a 雑誌掲載論文
  3. 学術雑誌

Performance of JT-60SA divertor Thomson scattering diagnostics

http://hdl.handle.net/2237/00030855
http://hdl.handle.net/2237/00030855
f576c9e9-1a51-4c85-9ad2-2a75222f56f9
名前 / ファイル ライセンス アクション
1_4929514.pdf 1_4929514 (2.6 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-11-07
タイトル
タイトル Performance of JT-60SA divertor Thomson scattering diagnostics
言語 en
著者 Kajita, Shin

× Kajita, Shin

WEKO 94094

en Kajita, Shin

Search repository
Hatae, Takaki

× Hatae, Takaki

WEKO 94095

en Hatae, Takaki

Search repository
Tojo, Hiroshi

× Tojo, Hiroshi

WEKO 94096

en Tojo, Hiroshi

Search repository
Enokuchi, Akito

× Enokuchi, Akito

WEKO 94097

en Enokuchi, Akito

Search repository
Hamano, Takashi

× Hamano, Takashi

WEKO 94098

en Hamano, Takashi

Search repository
Shimizu, Katsuhiro

× Shimizu, Katsuhiro

WEKO 94099

en Shimizu, Katsuhiro

Search repository
Kawashima, Hisato

× Kawashima, Hisato

WEKO 94100

en Kawashima, Hisato

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 Copyright 2015 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing.The following article appeared in (Review of Scientific Instruments. v.86, n.8, 2015, p.083511) and may be found at (http://dx.doi.org/10.1063/1.4929514).
抄録
内容記述 For the satellite tokamak JT-60 Super Advanced (JT-60SA), a divertor Thomson scattering measurement system is planning to be installed. In this study, we improved the design of the collection optics based on the previous one, in which it was found that the solid angle of the collection optics became very small, mainly because of poor accessibility to the measurement region. By improvement, the solid angle was increased by up to approximately five times. To accurately assess the measurement performance, background noise was assessed using the plasma parameters in two typical discharges in JT-60SA calculated from the SONIC code. Moreover, the influence of the reflection of bremsstrahlung radiation by the wall is simulated by using a ray tracing simulation. The errors in the temperature and the density are assessed based on the simulation results for three typical field of views.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 AIP Publishing
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1063/1.4929514
ISSN(print)
収録物識別子タイプ PISSN
収録物識別子 0034-6748
書誌情報 en : Review of Scientific Instruments

巻 86, 号 8, p. 083511, 発行日 2015-08
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:54:34.026156
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3