{"_buckets": {"deposit": "0c1ce64c-f935-40ba-aa21-0901b0a9881e"}, "_deposit": {"id": "29353", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "29353"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00029353", "sets": ["2478"]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "68", "bibliographicPageStart": "59", "bibliographicVolumeNumber": "82", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Most traumatic pneumothoraxes and hemothoraxes can be managed non-operatively by means of chest tube thoracostomy. This study aimed to investigate how emergency physicians choose chest tube size and whether chest tube size affects patient outcome. We reviewed medical charts of patients who underwent chest tube insertion for chest trauma within 24 hours of admission in this retrospective, single-institution study. Patient characteristics, inserted tube size, risk of additional tube, and complications were evaluated. Eighty-six chest tubes were placed in 64 patients. Sixty-seven tubes were placed initially, and 19 additionally, which was significantly smaller than the initial tube. Initial tube size was 28 Fr in 38 and \u003c28 Fr in 28 patients. Indications were pneumothorax (n=24), hemothorax (n=7), and hemopneumothorax (n=36). Initial tube size was not related to sex, BMI, BSA, indication, ISS, RTS, chest AIS, or respiratory status. An additional tube was placed in the same thoracic cavity for residual pneumothorax (n=13), hemothorax (n=1), hemopneumothorax (n=1), and inappropriate extrapleural placement (n=3). Risk of additional tube placement was not significantly different depending on tube size. No additional tube was placed for tube occlusion or surgical intervention for residual clotted hemothorax. Emergency physicians did not choose tube size depending on patient sex, body size, or situation. Even with a \u003c28 Fr tube placed in chest trauma patients, the risk of residual hemo/pneumothorax and tube occlusion did not increase, and drainage was effective.", "subitem_description_type": "Abstract"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.82.1.59", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University Graduate School of Medicine, School of Medicine"}]}, "item_9_relation_43": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/821.html ", "subitem_relation_type_select": "URI"}}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_61": {"attribute_name": "ISSN(Online)", "attribute_value_mlt": [{"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Terada, Takafumi"}], "nameIdentifiers": [{"nameIdentifier": "96311", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishimura, Tetsuro"}], "nameIdentifiers": [{"nameIdentifier": "96312", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchida, Kenichiro"}], "nameIdentifiers": [{"nameIdentifier": "96313", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hagawa, Naohiro"}], "nameIdentifiers": [{"nameIdentifier": "96314", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Esaki, Maiko"}], "nameIdentifiers": [{"nameIdentifier": "96315", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizobata, Yasumitsu"}], "nameIdentifiers": [{"nameIdentifier": "96316", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-02-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "08_Terada.pdf", "filesize": [{"value": "1.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1000000.0, "url": {"label": "08_Terada.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/29353/files/08_Terada.pdf"}, "version_id": "0c39167a-d6c3-4dfd-9812-9fd61732b7ed"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "chest tube size", "subitem_subject_scheme": "Other"}, {"subitem_subject": "thoracic trauma", "subitem_subject_scheme": "Other"}, {"subitem_subject": "tube thoracotomy", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "How emergency physicians choose chest tube size for traumatic pneumothorax or hemothorax: a comparison between 28Fr and smaller tube", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "How emergency physicians choose chest tube size for traumatic pneumothorax or hemothorax: a comparison between 28Fr and smaller tube"}]}, "item_type_id": "9", "owner": "1", "path": ["2478"], "permalink_uri": "https://doi.org/10.18999/nagjms.82.1.59", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-02-26"}, "publish_date": "2020-02-26", "publish_status": "0", "recid": "29353", "relation": {}, "relation_version_is_last": true, "title": ["How emergency physicians choose chest tube size for traumatic pneumothorax or hemothorax: a comparison between 28Fr and smaller tube"], "weko_shared_id": null}
  1. C100 医学部/医学系研究科
  2. C100b 紀要
  3. Nagoya journal of medical science
  4. 82(1)

How emergency physicians choose chest tube size for traumatic pneumothorax or hemothorax: a comparison between 28Fr and smaller tube

https://doi.org/10.18999/nagjms.82.1.59
https://doi.org/10.18999/nagjms.82.1.59
005f6dce-a7d9-4811-9e26-8584e179ec36
名前 / ファイル ライセンス アクション
08_Terada.pdf 08_Terada.pdf (1.0 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2020-02-26
タイトル
タイトル How emergency physicians choose chest tube size for traumatic pneumothorax or hemothorax: a comparison between 28Fr and smaller tube
著者 Terada, Takafumi

× Terada, Takafumi

WEKO 96311

Terada, Takafumi

Search repository
Nishimura, Tetsuro

× Nishimura, Tetsuro

WEKO 96312

Nishimura, Tetsuro

Search repository
Uchida, Kenichiro

× Uchida, Kenichiro

WEKO 96313

Uchida, Kenichiro

Search repository
Hagawa, Naohiro

× Hagawa, Naohiro

WEKO 96314

Hagawa, Naohiro

Search repository
Esaki, Maiko

× Esaki, Maiko

WEKO 96315

Esaki, Maiko

Search repository
Mizobata, Yasumitsu

× Mizobata, Yasumitsu

WEKO 96316

Mizobata, Yasumitsu

Search repository
キーワード
主題Scheme Other
主題 chest tube size
キーワード
主題Scheme Other
主題 thoracic trauma
キーワード
主題Scheme Other
主題 tube thoracotomy
抄録
内容記述 Most traumatic pneumothoraxes and hemothoraxes can be managed non-operatively by means of chest tube thoracostomy. This study aimed to investigate how emergency physicians choose chest tube size and whether chest tube size affects patient outcome. We reviewed medical charts of patients who underwent chest tube insertion for chest trauma within 24 hours of admission in this retrospective, single-institution study. Patient characteristics, inserted tube size, risk of additional tube, and complications were evaluated. Eighty-six chest tubes were placed in 64 patients. Sixty-seven tubes were placed initially, and 19 additionally, which was significantly smaller than the initial tube. Initial tube size was 28 Fr in 38 and <28 Fr in 28 patients. Indications were pneumothorax (n=24), hemothorax (n=7), and hemopneumothorax (n=36). Initial tube size was not related to sex, BMI, BSA, indication, ISS, RTS, chest AIS, or respiratory status. An additional tube was placed in the same thoracic cavity for residual pneumothorax (n=13), hemothorax (n=1), hemopneumothorax (n=1), and inappropriate extrapleural placement (n=3). Risk of additional tube placement was not significantly different depending on tube size. No additional tube was placed for tube occlusion or surgical intervention for residual clotted hemothorax. Emergency physicians did not choose tube size depending on patient sex, body size, or situation. Even with a <28 Fr tube placed in chest trauma patients, the risk of residual hemo/pneumothorax and tube occlusion did not increase, and drainage was effective.
内容記述タイプ Abstract
出版者
出版者 Nagoya University Graduate School of Medicine, School of Medicine
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
ID登録
ID登録 10.18999/nagjms.82.1.59
ID登録タイプ JaLC
関連情報
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/821.html
ISSN(print)
収録物識別子タイプ ISSN
収録物識別子 0027-7622
ISSN(Online)
収録物識別子タイプ ISSN
収録物識別子 2186-3326
書誌情報 Nagoya Journal of Medical Science

巻 82, 号 1, p. 59-68, 発行日 2020-02
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:36:21.942119
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3