WEKO3
アイテム
Correlation between blood flow, tissue volume and microvessel density in the flap
https://doi.org/10.18999/nagjms.82.2.291
https://doi.org/10.18999/nagjms.82.2.291429e4fba-9efa-4993-8cd3-7c975fe7ba4a
名前 / ファイル | ライセンス | アクション |
---|---|---|
13_Nakamura.pdf (7.4 MB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-06-01 | |||||
タイトル | ||||||
タイトル | Correlation between blood flow, tissue volume and microvessel density in the flap | |||||
言語 | en | |||||
著者 |
Nakamura, Yutaka
× Nakamura, Yutaka× Takanari, Keisuke× Nakamura, Ryota× Ono, Masashi× Uchibori, Takafumi× Hishida, Masashi× Murotani, Kenta× Ebisawa, Katsumi× Akagawa, Miki× Kamei, Yuzuru |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報Resource | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |||||
権利情報 | Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | conductance | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | free flap transplantation | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | vessel resistance | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | blood flow | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | microvessel density | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to assess the correlation between tissue volume and blood flow of the flap in an animal model. Using animal model, tissue volume can be attenuated, and precise change of blood flow could be evaluated. We further investigate the relationship between blood flow and vascular density in the tissue. In this study, we assessed flap conductance (ml/min/mm Hg) as to evaluate the conductivity of blood flow into the flap. Japanese white rabbit was used (n = 7) for this study. The amount of blood flow of jejunal and latissimus dorsi muscle (LD) flaps was measured while removing the distal portion of the flap sequentially. Conductance at each time was calculated from blood pressure and blood flow volume. The tissue volume at each time was also measured. The correlation between conductance and volume was analyzed using a linear mixed model. Immunohistochemical evaluation of microvessel densities (MVD) in these tissues was also performed for CD31/PECAM1 positive area. Conductance and tissue volume were significantly correlated in both jejunal and LD flaps. As the volume increases by 1 cm^3, the conductance increased significantly by 0.012 ml/min/mm Hg in jejunum, and by 0.0047 ml/min/mm Hg in LD. Mean MVD was 1.15 ± 0.52% in the jejunum and 0.37 ± 0.29% in the LD muscle. In this study, we revealed that flap conductance is proportional to volume and proportional constant is different between the type of tissue. It suggests that the difference of MVD creates the unique conductance of each tissue. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | Nagoya University Graduate School of Medicine, School of Medicine | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.82.2.291 | |||||
ID登録タイプ | JaLC | |||||
関連情報 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.med.nagoya-u.ac.jp/medlib/nagoya_j_med_sci/822.html | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 82, 号 2, p. 291-300, 発行日 2020-05 |
|||||
著者版フラグ | ||||||
値 | publisher |