WEKO3
アイテム
{"_buckets": {"deposit": "3d218788-da84-4953-9f2a-48b35e74b883"}, "_deposit": {"created_by": 17, "id": "4615", "owners": [17], "pid": {"revision_id": 0, "type": "depid", "value": "4615"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00004615", "sets": []}, "author_link": ["11575", "11576", "11577", "11578", "11579", "11580", "11581", "11582", "11583", "11584", "11585"], "item_1615768549627": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_9_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-2", "bibliographicPageEnd": "52", "bibliographicPageStart": "45", "bibliographicVolumeNumber": "68", "bibliographic_titles": [{"bibliographic_title": "Nagoya Journal of Medical Science", "bibliographic_titleLang": "en"}]}]}, "item_9_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Computer-assisted surgery, which provides simultaneous, multiplanar images of bone structures, has become widely used. However, registration maneuvering remains time consuming. The objective of this paper is to document the usefulness of CT-fl uoro matching for spinal navigation. A spinal navigation system (VECTORVISIONR compact; Brain LAB, Germany) and a digital imaging system (OEC9800; CATHEX, Tokyo, Japan) were used for CT-fl uoro matching in cases of L4/5 and L5/S1 posterior lumbar interbody fusion. A reference array was attached to the L4 spinous process. Preoperative CT images and intraoperative fl uoro-shots including L4, L5, and S1 were superimposed on the navigation monitor. Following insertion of L4 screws, a reference array remained to be attached to the L4 spinous process, after which a level defi nition and pre-registration of L5 and S1 vertebrae were performed and the screwing procedure of L5 and S1 was completed without additional fl uro-shots. Registration of three vertebrae was completed without paired-point or surface-matching procedures. The calculation time for the registration in a single vertebra was 30 sec. All pedicle screws were seen to be successfully inserted on postoperative CT images. We performed the navigation surgery by matching the preoperative CT images to the intraoperative fl uoro-shots without manual registration. This technique may prove useful in the future for anterior spinal surgery and percutaneous screwing without the need for total exposure of the bone surface.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_9_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/6132"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18999/nagjms.68.1-2.45", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nagoya University School of Medicine", "subitem_publisher_language": "en"}]}, "item_9_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_9_source_id_61": {"attribute_name": "ISSN(Online)", "attribute_value_mlt": [{"subitem_source_identifier": "2186-3326", "subitem_source_identifier_type": "EISSN"}]}, "item_9_source_id_7": {"attribute_name": "ISSN(print)", "attribute_value_mlt": [{"subitem_source_identifier": "0027-7622", "subitem_source_identifier_type": "PISSN"}]}, "item_9_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sakai, Yoshihito", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "11575", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuyama, Yukihiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "11576", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshihara, Hisatake", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "11577", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamura, Hiroshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "11578", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakashima, Shojiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "11579", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishiguro, Naoki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "11580", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酒井, 義人", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "11581", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松山, 幸弘", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "11582", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉原, 永武", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "11583", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村, 博司", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "11584", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石黒, 直樹", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "11585", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "p045_052.pdf", "filesize": [{"value": "583.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 583000.0, "url": {"label": "p045_052.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/4615/files/p045_052.pdf"}, "version_id": "5db0fa9c-8128-44ee-b446-dded8470a53d"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Navigation surgery", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Registration", "subitem_subject_scheme": "Other"}, {"subitem_subject": "CT-fl uoro matching", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Pedicle screw", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Simultaneous registration with CT-fluoro matching for spinal navigation surgery", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Simultaneous registration with CT-fluoro matching for spinal navigation surgery", "subitem_title_language": "en"}]}, "item_type_id": "9", "owner": "17", "path": ["605"], "permalink_uri": "https://doi.org/10.18999/nagjms.68.1-2.45", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2006-03-01"}, "publish_date": "2006-03-01", "publish_status": "0", "recid": "4615", "relation": {}, "relation_version_is_last": true, "title": ["Simultaneous registration with CT-fluoro matching for spinal navigation surgery"], "weko_shared_id": -1}
Simultaneous registration with CT-fluoro matching for spinal navigation surgery
https://doi.org/10.18999/nagjms.68.1-2.45
https://doi.org/10.18999/nagjms.68.1-2.45bd418b82-3018-46f1-9d19-5089d9afaedb
名前 / ファイル | ライセンス | アクション |
---|---|---|
p045_052.pdf (583.0 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-03-01 | |||||
タイトル | ||||||
タイトル | Simultaneous registration with CT-fluoro matching for spinal navigation surgery | |||||
言語 | en | |||||
著者 |
Sakai, Yoshihito
× Sakai, Yoshihito× Matsuyama, Yukihiro× Yoshihara, Hisatake× Nakamura, Hiroshi× Nakashima, Shojiro× Ishiguro, Naoki× 酒井, 義人× 松山, 幸弘× 吉原, 永武× 中村, 博司× 石黒, 直樹 |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Navigation surgery | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Registration | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | CT-fl uoro matching | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Pedicle screw | |||||
抄録 | ||||||
内容記述 | Computer-assisted surgery, which provides simultaneous, multiplanar images of bone structures, has become widely used. However, registration maneuvering remains time consuming. The objective of this paper is to document the usefulness of CT-fl uoro matching for spinal navigation. A spinal navigation system (VECTORVISIONR compact; Brain LAB, Germany) and a digital imaging system (OEC9800; CATHEX, Tokyo, Japan) were used for CT-fl uoro matching in cases of L4/5 and L5/S1 posterior lumbar interbody fusion. A reference array was attached to the L4 spinous process. Preoperative CT images and intraoperative fl uoro-shots including L4, L5, and S1 were superimposed on the navigation monitor. Following insertion of L4 screws, a reference array remained to be attached to the L4 spinous process, after which a level defi nition and pre-registration of L5 and S1 vertebrae were performed and the screwing procedure of L5 and S1 was completed without additional fl uro-shots. Registration of three vertebrae was completed without paired-point or surface-matching procedures. The calculation time for the registration in a single vertebra was 30 sec. All pedicle screws were seen to be successfully inserted on postoperative CT images. We performed the navigation surgery by matching the preoperative CT images to the intraoperative fl uoro-shots without manual registration. This technique may prove useful in the future for anterior spinal surgery and percutaneous screwing without the need for total exposure of the bone surface. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | en | |||||
出版者 | Nagoya University School of Medicine | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ID登録 | ||||||
ID登録 | 10.18999/nagjms.68.1-2.45 | |||||
ID登録タイプ | JaLC | |||||
ISSN(print) | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0027-7622 | |||||
ISSN(Online) | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 2186-3326 | |||||
書誌情報 |
en : Nagoya Journal of Medical Science 巻 68, 号 1-2, p. 45-52, 発行日 2006-01 |
|||||
フォーマット | ||||||
application/pdf | ||||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/6132 | |||||
識別子タイプ | HDL |