A method for automated extraction of aorta and pulmonary artery in the mediastinum using medial line models from 3D chest X-ray CT images without contrast materials

http://hdl.handle.net/2237/6865
http://hdl.handle.net/2237/6865
2d87d16d-20ac-4bc8-95fb-889166806643
名前 / ファイル ライセンス アクション
amethodforautomated.pdf amethodforautomated.pdf (575.1 kB)
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2006-08-28
タイトル
タイトル A method for automated extraction of aorta and pulmonary artery in the mediastinum using medial line models from 3D chest X-ray CT images without contrast materials
言語 en
著者 Kitasaka, Takayuki

× Kitasaka, Takayuki

WEKO 13352

en Kitasaka, Takayuki

Search repository
Mori, Kensaku

× Mori, Kensaku

WEKO 13353

en Mori, Kensaku

Search repository
Hasegawa, Jun-ichi

× Hasegawa, Jun-ichi

WEKO 13354

en Hasegawa, Jun-ichi

Search repository
Toriwaki, Jun-ichiro

× Toriwaki, Jun-ichiro

WEKO 13355

en Toriwaki, Jun-ichiro

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
権利情報 Copyright © 2002 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.
言語 en
抄録
内容記述タイプ Abstract
内容記述 This paper proposes a new method of automated extraction of aorta and pulmonary artery (PA) areas in the mediastinum from uncontrasted 3D chest X-ray CT images. The proposed method does not extract contours of these blood vessels directly, but extracts the medial line of each vessel and recovers each vessel and recovers each vessel area. First, the process performs edge detectiion based on the local standard deviation to get edge areas of vessels. Second, the Euclidean distance transformation is applied for non-edge areas and the likelihood image of the center of vessels is obtained. Medial line models are deformed basing upon the likelihood image so as to be fit to the center of each artery. The aorta and the PA areas are obtained by applying the reverse distance transformation to medial lines extracted above. We applied the proposed method to seven cases of uncontrasted 3D chest X-ray CT images. The experimental results showed that the aorta and the PA areas could be extracted satisfactorily.
言語 en
出版者
出版者 IEEE
言語 en
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1109/ICPR.2002.1047847
書誌情報 en : Proceedings of the 16th International Conference on Pattern Recognition

巻 3, p. 273-276, 発行日 2002-08
フォーマット
値 application/pdf
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/6865
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 13:14:46.114225
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3