{"_buckets": {"deposit": "4b7b11e5-5085-4223-b35d-3f485ca94f6c"}, "_deposit": {"id": "5355", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "5355"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00005355"}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "1246", "bibliographicPageStart": "1242", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "Measurement Science and Technology"}]}]}, "item_10_description_4": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "Pressure sensitive paint (PSP) techniques have the capability to be applied to high Knudsen number flows, such as low density gas flows, micro-flows, and so on. In this study, to inspect the feasibility of PSP for measurement of pressure on a solid surface in high Knudsen number flows, fundamental properties of PSPs are examined especially in the range of pressure below 130 Pa (about 1 Torr). As a result, it is clarified that the PSP using poly(TMSP) as a binder and using PdOEP or PdTFPP as a luminophore has very high sensitivity to oxygen pressure in low pressure conditions below 130 Pa. Pressure sensitivity to nitrogen monoxide is also examined for the above PSPs, and it is clarified that PdTFPP bound by poly(TMSP) has very high sensitivity while PdOEP has very low sensitivity to nitrogen monoxide. The combination of the PdTFPP-based PSP and NO-LIF technique enables\ncomposite measurement of flow field structures and surface pressure in high-Kn regime.", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/6960"}]}, "item_10_publisher_32": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "IOP"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://dx.doi.org/10.1088/0957-0233/17/6/S02", "subitem_relation_type_select": "DOI"}}]}, "item_10_select_15": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0957-0233", "subitem_source_identifier_type": "ISSN"}]}, "item_10_text_14": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "13644", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Niimi, Tomohide"}], "nameIdentifiers": [{"nameIdentifier": "13645", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirako, Madoka"}], "nameIdentifiers": [{"nameIdentifier": "13646", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uenishi, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "13647", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "MST_PSP.pdf", "filesize": [{"value": "159.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 159000.0, "url": {"label": "MST_PSP.pdf", "url": "https://nagoya.repo.nii.ac.jp/record/5355/files/MST_PSP.pdf"}, "version_id": "0ccbad05-67f8-4920-ae33-7d72cc555c94"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "pressure sensitive paints", "subitem_subject_scheme": "Other"}, {"subitem_subject": "sensors", "subitem_subject_scheme": "Other"}, {"subitem_subject": "rarefied gas dynamics", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Pressure Sensitive Paint Suitable to High Knudsen Number Regime", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "Pressure Sensitive Paint Suitable to High Knudsen Number Regime"}]}, "item_type_id": "10", "owner": "1", "path": ["320/321/322"], "permalink_uri": "http://hdl.handle.net/2237/6960", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2006-09-22"}, "publish_date": "2006-09-22", "publish_status": "0", "recid": "5355", "relation": {}, "relation_version_is_last": true, "title": ["Pressure Sensitive Paint Suitable to High Knudsen Number Regime"], "weko_shared_id": 3}
  1. B200 工学部/工学研究科
  2. B200a 雑誌掲載論文
  3. 学術雑誌

Pressure Sensitive Paint Suitable to High Knudsen Number Regime

http://hdl.handle.net/2237/6960
06291ea2-094a-4578-b2e5-fa9681d91c3c
名前 / ファイル ライセンス アクション
MST_PSP.pdf MST_PSP.pdf (159.0 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-09-22
タイトル
タイトル Pressure Sensitive Paint Suitable to High Knudsen Number Regime
著者 Mori, Hideo

× Mori, Hideo

WEKO 13644

Mori, Hideo

Search repository
Niimi, Tomohide

× Niimi, Tomohide

WEKO 13645

Niimi, Tomohide

Search repository
Hirako, Madoka

× Hirako, Madoka

WEKO 13646

Hirako, Madoka

Search repository
Uenishi, Hiroyuki

× Uenishi, Hiroyuki

WEKO 13647

Uenishi, Hiroyuki

Search repository
キーワード
主題Scheme Other
主題 pressure sensitive paints
キーワード
主題Scheme Other
主題 sensors
キーワード
主題Scheme Other
主題 rarefied gas dynamics
抄録
内容記述 Pressure sensitive paint (PSP) techniques have the capability to be applied to high Knudsen number flows, such as low density gas flows, micro-flows, and so on. In this study, to inspect the feasibility of PSP for measurement of pressure on a solid surface in high Knudsen number flows, fundamental properties of PSPs are examined especially in the range of pressure below 130 Pa (about 1 Torr). As a result, it is clarified that the PSP using poly(TMSP) as a binder and using PdOEP or PdTFPP as a luminophore has very high sensitivity to oxygen pressure in low pressure conditions below 130 Pa. Pressure sensitivity to nitrogen monoxide is also examined for the above PSPs, and it is clarified that PdTFPP bound by poly(TMSP) has very high sensitivity while PdOEP has very low sensitivity to nitrogen monoxide. The combination of the PdTFPP-based PSP and NO-LIF technique enables
composite measurement of flow field structures and surface pressure in high-Kn regime.
内容記述タイプ Abstract
出版者
出版者 IOP
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
DOI
関連識別子
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1088/0957-0233/17/6/S02
ISSN
収録物識別子タイプ ISSN
収録物識別子 0957-0233
書誌情報 Measurement Science and Technology

巻 17, p. 1242-1246, 発行日 2006
フォーマット
application/pdf
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/6960
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 13:13:38.873892
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio