WEKO3
アイテム
3RD HARMONIC OPERATION OF SIT INVERTER RF SOURCE FOR ICRF HEATING IN THE DIVERTOR PLASMA SIMULATOR NAGDIS-II
http://hdl.handle.net/2237/7170
http://hdl.handle.net/2237/717056e31ca2-8dbc-4cb6-a691-f3dff6d7e721
名前 / ファイル | ライセンス | アクション |
---|---|---|
ICOPS_2001_1677.pdf (315.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-12-12 | |||||
タイトル | ||||||
タイトル | 3RD HARMONIC OPERATION OF SIT INVERTER RF SOURCE FOR ICRF HEATING IN THE DIVERTOR PLASMA SIMULATOR NAGDIS-II | |||||
言語 | en | |||||
著者 |
Uesugi, Y.
× Uesugi, Y.× Imai, T.× Kawada, K.× Takamura, S. |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | Copyright © 2001 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this paper is to study the 3rd harmonic operation of a voltage source inverter power supply. A Static Induction Transistor (SIT) inverter power supply is used in this experiment. This power supply can generate 14 kW in steady state operation and its upper limit frequency of the gate driver is 1.7 MHz. The advantage of the 3rd harmonic operation is that the RF power at higher frequency range beyond the switching limit can be generated. It should be also noted that the driver circuit needs no special modification for this operation. The conversion efficiency and maximum output power are investigated as a function of output frequency. The conversion efficiency with harmonic operation is a little lower than the conversion efficiency with fundamental operation. At the frequency of <3 MHz, the conversion efficiency is higher than that of conventional linear amplifiers when using this SIT inverter power supply. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | IEEE | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/PPPS.2001.1001891 | |||||
ISBN | ||||||
関連タイプ | isPartOf | |||||
識別子タイプ | ISBN | |||||
関連識別子 | 0-7803-7120-8 | |||||
書誌情報 |
en : Digest of Technical Papers Pulsed Power Plasma Science (PPPS-2001) 巻 2, p. 1677-1680, 発行日 2001-06 |
|||||
フォーマット | ||||||
値 | application/pdf | |||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/7170 | |||||
識別子タイプ | HDL |