ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "bb6a5b93-84a6-43c4-b108-32acacedc041"}, "_deposit": {"id": "5701", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "5701"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00005701", "sets": ["322"]}, "author_link": ["15157", "15158", "15159", "15160", "15161", "15162", "15163"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000-10-15", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "15-20", "bibliographicPageEnd": "6/234", "bibliographicPageStart": "6/231", "bibliographicVolumeNumber": "1", "bibliographic_titles": [{"bibliographic_title": "2000 IEEE Nuclear Science Symposium Conference record", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purpose of this study is to develop a radiation distribution monitor using a normal plastic optical fiber. The monitor has a long operating length and can obtain continuous radiation distributions. A principle of the position sensing is based on a time-of-flight technique. The monitor is sensitive to beta rays or charged particles, gamma rays, and fast neutrons. The spatial resolutions for beta rays ( 90Sr-90Y), gamma rays (137Cs) and D-T neutrons are 30 cm, 37 cm and 13 cm, respectively. The detection efficiencies for the beta rays, the gamma rays and D-T neutrons are 0.11%, 1.6*10^{-5}% and 1.2*10^{-4}%, respectively. The effective attenuation length of the detection efficiency is 18 m. In this paper, we describe the basic characteristics of this monitor.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/7307"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE", "subitem_publisher_language": "en"}]}, "item_10_relation_8": {"attribute_name": "ISBN", "attribute_value_mlt": [{"subitem_relation_type": "isPartOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "0-7803-6503-8", "subitem_relation_type_select": "ISBN"}}]}, "item_10_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 2000 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.", "subitem_rights_language": "en"}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Naka, R.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15157", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawarabayashi, J.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15158", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uritani, A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15159", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iguchi, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15160", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kaneko, J.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15161", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takeuchi, H.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15162", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kakuta, T.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15163", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "nuclear_sci_sympo_1998_231.pdf", "filesize": [{"value": "477.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 477900.0, "url": {"label": "nuclear_sci_sympo_1998_231.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/5701/files/nuclear_sci_sympo_1998_231.pdf"}, "version_id": "064e0524-8d06-42cc-a4b8-fb2b2386ba33"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Radiation Distribution Sensing with Normal Optical Fiber", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Radiation Distribution Sensing with Normal Optical Fiber", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/7307", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2007-02-19"}, "publish_date": "2007-02-19", "publish_status": "0", "recid": "5701", "relation": {}, "relation_version_is_last": true, "title": ["Radiation Distribution Sensing with Normal Optical Fiber"], "weko_shared_id": -1}
  1. B200 工学部/工学研究科
  2. B200a 雑誌掲載論文
  3. 学術雑誌

Radiation Distribution Sensing with Normal Optical Fiber

http://hdl.handle.net/2237/7307
http://hdl.handle.net/2237/7307
167acc24-dfd4-4546-9c96-81fbb5f9b37d
名前 / ファイル ライセンス アクション
nuclear_sci_sympo_1998_231.pdf nuclear_sci_sympo_1998_231.pdf (477.9 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-02-19
タイトル
タイトル Radiation Distribution Sensing with Normal Optical Fiber
言語 en
著者 Naka, R.

× Naka, R.

WEKO 15157

en Naka, R.

Search repository
Kawarabayashi, J.

× Kawarabayashi, J.

WEKO 15158

en Kawarabayashi, J.

Search repository
Uritani, A.

× Uritani, A.

WEKO 15159

en Uritani, A.

Search repository
Iguchi, T.

× Iguchi, T.

WEKO 15160

en Iguchi, T.

Search repository
Kaneko, J.

× Kaneko, J.

WEKO 15161

en Kaneko, J.

Search repository
Takeuchi, H.

× Takeuchi, H.

WEKO 15162

en Takeuchi, H.

Search repository
Kakuta, T.

× Kakuta, T.

WEKO 15163

en Kakuta, T.

Search repository
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
権利
言語 en
権利情報 Copyright © 2000 IEEE. Reprinted from (relevant publication info). This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Nagoya University’s products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to pubs-permissions@ieee.org.
抄録
内容記述 The purpose of this study is to develop a radiation distribution monitor using a normal plastic optical fiber. The monitor has a long operating length and can obtain continuous radiation distributions. A principle of the position sensing is based on a time-of-flight technique. The monitor is sensitive to beta rays or charged particles, gamma rays, and fast neutrons. The spatial resolutions for beta rays ( 90Sr-90Y), gamma rays (137Cs) and D-T neutrons are 30 cm, 37 cm and 13 cm, respectively. The detection efficiencies for the beta rays, the gamma rays and D-T neutrons are 0.11%, 1.6*10^{-5}% and 1.2*10^{-4}%, respectively. The effective attenuation length of the detection efficiency is 18 m. In this paper, we describe the basic characteristics of this monitor.
言語 en
内容記述タイプ Abstract
出版者
言語 en
出版者 IEEE
言語
言語 eng
資源タイプ
資源タイプresource http://purl.org/coar/resource_type/c_6501
タイプ journal article
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
ISBN
関連タイプ isPartOf
識別子タイプ ISBN
関連識別子 0-7803-6503-8
書誌情報 en : 2000 IEEE Nuclear Science Symposium Conference record

巻 1, 号 15-20, p. 6/231-6/234, 発行日 2000-10-15
フォーマット
application/pdf
著者版フラグ
値 publisher
URI
識別子 http://hdl.handle.net/2237/7307
識別子タイプ HDL
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 20:23:13.080446
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3