WEKO3
アイテム
{"_buckets": {"deposit": "beac286f-785f-4299-8f2e-79dcc7927a3f"}, "_deposit": {"id": "7079", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "7079"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00007079", "sets": ["322"]}, "author_link": ["19096", "19097", "19098", "19099", "19100"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "203", "bibliographicPageStart": "199", "bibliographicVolumeNumber": "21", "bibliographic_titles": [{"bibliographic_title": "Analytical Sciences", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The determination of 34 trace metals in a river water certified reference material (CRM), i.e. JSAC 0301-1, which was issued by the Japan Society for Analytical Chemistry in January 2004, was performed by ICP-MS with a high efficiency nebulizer after preconcentration with a laboratory-made chelating resin-packed minicolumn, with which trace metals were concentrated 100-fold from 50 mL of a river water sample to 0.5 mL of the final analysis solution. Trace metals in JSAC 0301-1 were observed in the concentration range from 19 µg L^-1 of Al to 0.000053 µg L^-1 of Bi. It was found that most of the concentrations of trace metals, including rare earth elements (REEs), in JSAC 0301-1 were lower than those in JAC 0031, which was also a previously issued CRM prepared with water from the same river as that of JSAC 0301-1. The low concentrations of trace metals in JSAC 0301-1 might be attributed to the fact that there was a heavy rain before collecting the original water sample to prepare the present CRM. Furthermore, the REE distribution patterns of JSAC 0301-1, JAC 0031 and the average values of river water samples in Japan were parallel to each other. These results indicate that the distributions of REEs in JSAC 0301-1 and JAC 0031 were the typical ones of river water samples in Japan.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/8752"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本分析化学会", "subitem_publisher_language": "ja"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.2116/analsci.21.199", "subitem_relation_type_select": "DOI"}}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-6340", "subitem_source_identifier_type": "PISSN"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "ZHU, Yanbei", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19096", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HATTORI, Ryota", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19097", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "FUJIMORI, Eiji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19098", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "UMEMURA, Tomonari", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19099", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HARAGUCHI, Hiroki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19100", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "v21_n3_199-203.pdf", "filesize": [{"value": "69.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 69700.0, "url": {"label": "v21_n3_199-203.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/7079/files/v21_n3_199-203.pdf"}, "version_id": "0ba00a5f-2dec-4ccb-90ba-0001dd42df42"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Multielement Determination of Trace Metals in River Water (Certified Reference Material, JSAC 0301-1) by High Efficiency Nebulization ICP-MS after 100-fold Preconcentration with a Chelating Resin-Packed Minicolumn", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Multielement Determination of Trace Metals in River Water (Certified Reference Material, JSAC 0301-1) by High Efficiency Nebulization ICP-MS after 100-fold Preconcentration with a Chelating Resin-Packed Minicolumn", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/8752", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2007-09-14"}, "publish_date": "2007-09-14", "publish_status": "0", "recid": "7079", "relation": {}, "relation_version_is_last": true, "title": ["Multielement Determination of Trace Metals in River Water (Certified Reference Material, JSAC 0301-1) by High Efficiency Nebulization ICP-MS after 100-fold Preconcentration with a Chelating Resin-Packed Minicolumn"], "weko_shared_id": -1}
Multielement Determination of Trace Metals in River Water (Certified Reference Material, JSAC 0301-1) by High Efficiency Nebulization ICP-MS after 100-fold Preconcentration with a Chelating Resin-Packed Minicolumn
http://hdl.handle.net/2237/8752
http://hdl.handle.net/2237/87520e09ace9-fb2f-45e7-8cc2-f13e7e07e22a
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-09-14 | |||||
タイトル | ||||||
タイトル | Multielement Determination of Trace Metals in River Water (Certified Reference Material, JSAC 0301-1) by High Efficiency Nebulization ICP-MS after 100-fold Preconcentration with a Chelating Resin-Packed Minicolumn | |||||
言語 | en | |||||
著者 |
ZHU, Yanbei
× ZHU, Yanbei× HATTORI, Ryota× FUJIMORI, Eiji× UMEMURA, Tomonari× HARAGUCHI, Hiroki |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
抄録 | ||||||
内容記述 | The determination of 34 trace metals in a river water certified reference material (CRM), i.e. JSAC 0301-1, which was issued by the Japan Society for Analytical Chemistry in January 2004, was performed by ICP-MS with a high efficiency nebulizer after preconcentration with a laboratory-made chelating resin-packed minicolumn, with which trace metals were concentrated 100-fold from 50 mL of a river water sample to 0.5 mL of the final analysis solution. Trace metals in JSAC 0301-1 were observed in the concentration range from 19 µg L^-1 of Al to 0.000053 µg L^-1 of Bi. It was found that most of the concentrations of trace metals, including rare earth elements (REEs), in JSAC 0301-1 were lower than those in JAC 0031, which was also a previously issued CRM prepared with water from the same river as that of JSAC 0301-1. The low concentrations of trace metals in JSAC 0301-1 might be attributed to the fact that there was a heavy rain before collecting the original water sample to prepare the present CRM. Furthermore, the REE distribution patterns of JSAC 0301-1, JAC 0031 and the average values of river water samples in Japan were parallel to each other. These results indicate that the distributions of REEs in JSAC 0301-1 and JAC 0031 were the typical ones of river water samples in Japan. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
出版者 | ||||||
言語 | ja | |||||
出版者 | 日本分析化学会 | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.2116/analsci.21.199 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0910-6340 | |||||
書誌情報 |
en : Analytical Sciences 巻 21, 号 3, p. 199-203, 発行日 2005-06 |
|||||
フォーマット | ||||||
application/pdf | ||||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/8752 | |||||
識別子タイプ | HDL |