WEKO3
アイテム
{"_buckets": {"deposit": "e1fa9509-86b4-452a-b6ce-744d22ba20b6"}, "_deposit": {"id": "7083", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "7083"}, "status": "published"}, "_oai": {"id": "oai:nagoya.repo.nii.ac.jp:00007083", "sets": ["322"]}, "author_link": ["19125", "19126", "19127"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "sup", "bibliographicPageEnd": "i982", "bibliographicPageStart": "i979", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "Analytical Sciences", "bibliographic_titleLang": "en"}]}]}, "item_10_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The major-to-trace elements in the human blood serum samples, collected from the healthy volunteers as well as from the patients of specific diseases, were determined by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry) after acid digestion. The whole blood samples were collected with the silicone-coated syringes and centrifuged at 3000 rpm to obtain the serum samples. Then, the blood serum samples were digested with nitric acid on an aluminum bath. Finally, the residue of blood serum was dissolved with 0.1 M nitric acid to subject to the analyses by ICP-AES and ICP-MS. The analytical results were summarized as the radar charts, which indicated the relative concentrations of 14 elements in order to perform the multielement correlation analyses for medical diagnosis. Such multielement radar charts for specific disease patients were compared to those for the healthy volunteers. It was found that the concentrations of P and Cu in sera collected from healthy females were higher than those from healthy males, while those of Fe, Zn, Mo and Ag in sera from the former were lower than those from the latter. Furthermore, the significant increases in Cu, Se and Mo were clearly observed for non-Hodgkin’s lymphoma (blood cancer) patients.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Proceedings of IUPAC International Congress on Analytical Sciences 2001 (ICAS 2001)", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_10_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2237/8757"}]}, "item_10_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本分析化学会", "subitem_publisher_language": "ja"}]}, "item_10_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.14891/analscisp.17icas.0.i979.0", "subitem_relation_type_select": "DOI"}}]}, "item_10_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-6340", "subitem_source_identifier_type": "PISSN"}]}, "item_10_text_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_text_value": "application/pdf"}]}, "item_1615787544753": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "HASEGAWA, Takuya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19125", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "INAGAKI, Kazumi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19126", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HARAGUCHI, Hiroki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "19127", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-02-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "v17-S_i979-i982.pdf", "filesize": [{"value": "118.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 118400.0, "url": {"label": "v17-S_i979-i982.pdf", "objectType": "fulltext", "url": "https://nagoya.repo.nii.ac.jp/record/7083/files/v17-S_i979-i982.pdf"}, "version_id": "20ecbac8-22cd-48b3-a1e1-095053151e5e"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Multielement Correlation Analysis of Major-to-Trace Elements in Human Blood Serum for Medical Diagnosis as Studied by ICP-AES and ICP-MS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Multielement Correlation Analysis of Major-to-Trace Elements in Human Blood Serum for Medical Diagnosis as Studied by ICP-AES and ICP-MS", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["322"], "permalink_uri": "http://hdl.handle.net/2237/8757", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2007-09-18"}, "publish_date": "2007-09-18", "publish_status": "0", "recid": "7083", "relation": {}, "relation_version_is_last": true, "title": ["Multielement Correlation Analysis of Major-to-Trace Elements in Human Blood Serum for Medical Diagnosis as Studied by ICP-AES and ICP-MS"], "weko_shared_id": -1}
Multielement Correlation Analysis of Major-to-Trace Elements in Human Blood Serum for Medical Diagnosis as Studied by ICP-AES and ICP-MS
http://hdl.handle.net/2237/8757
http://hdl.handle.net/2237/875702e78331-f03b-4f17-b20b-c0a4d12d6398
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-09-18 | |||||
タイトル | ||||||
タイトル | Multielement Correlation Analysis of Major-to-Trace Elements in Human Blood Serum for Medical Diagnosis as Studied by ICP-AES and ICP-MS | |||||
言語 | en | |||||
著者 |
HASEGAWA, Takuya
× HASEGAWA, Takuya× INAGAKI, Kazumi× HARAGUCHI, Hiroki |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
抄録 | ||||||
内容記述 | The major-to-trace elements in the human blood serum samples, collected from the healthy volunteers as well as from the patients of specific diseases, were determined by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry) after acid digestion. The whole blood samples were collected with the silicone-coated syringes and centrifuged at 3000 rpm to obtain the serum samples. Then, the blood serum samples were digested with nitric acid on an aluminum bath. Finally, the residue of blood serum was dissolved with 0.1 M nitric acid to subject to the analyses by ICP-AES and ICP-MS. The analytical results were summarized as the radar charts, which indicated the relative concentrations of 14 elements in order to perform the multielement correlation analyses for medical diagnosis. Such multielement radar charts for specific disease patients were compared to those for the healthy volunteers. It was found that the concentrations of P and Cu in sera collected from healthy females were higher than those from healthy males, while those of Fe, Zn, Mo and Ag in sera from the former were lower than those from the latter. Furthermore, the significant increases in Cu, Se and Mo were clearly observed for non-Hodgkin’s lymphoma (blood cancer) patients. | |||||
言語 | en | |||||
内容記述タイプ | Abstract | |||||
内容記述 | ||||||
内容記述 | Proceedings of IUPAC International Congress on Analytical Sciences 2001 (ICAS 2001) | |||||
言語 | en | |||||
内容記述タイプ | Other | |||||
出版者 | ||||||
言語 | ja | |||||
出版者 | 日本分析化学会 | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプresource | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.14891/analscisp.17icas.0.i979.0 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0910-6340 | |||||
書誌情報 |
en : Analytical Sciences 巻 17, 号 sup, p. i979-i982, 発行日 2001 |
|||||
フォーマット | ||||||
application/pdf | ||||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/8757 | |||||
識別子タイプ | HDL |