WEKO3
アイテム
高クヌッセン数流れでの圧力計測に適した感圧分子膜の開発
http://hdl.handle.net/2237/9015
http://hdl.handle.net/2237/90156aa03a77-d47d-49f3-b2ad-60fd2e517aba
名前 / ファイル | ライセンス | アクション |
---|---|---|
JsMecEngB-72-718-1475.pdf (733.7 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-11-16 | |||||
タイトル | ||||||
タイトル | 高クヌッセン数流れでの圧力計測に適した感圧分子膜の開発 | |||||
言語 | ja | |||||
その他のタイトル | ||||||
その他のタイトル | Development of Pressure Sensitive Molecular Film Suitable to Pressure Measurement of High Knudsen Number Flows | |||||
言語 | en | |||||
著者 |
松田, 佑
× 松田, 佑× MATSUDA, Yu× 森, 英男× MORI, Hideo× 新美, 智秀× NIIMI, Tomohide× 上西, 裕之× UENISHI, Hiroyuki× 平光, 円× HIRAKO, Madoka |
|||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
権利 | ||||||
言語 | ja | |||||
権利情報 | 日本機械学会 | |||||
権利 | ||||||
言語 | ja | |||||
権利情報 | 本文データは学協会の許諾に基づきCiNiiから複製したものである。 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Flow Measurement | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Molecular Flow | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | PSP | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | High Knudsen Number Flow | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | LB Film | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The pressure-sensitive paint (PSP) has potential as a diagnostic tool for pressure measurement in the high Knudsen number regime because it works as a so-called “molecular sensor”. However, there are few reports concerning application of the PSP to micro devices because the conventional PSP is too thick owing to the use of polymer binder. In this study, we have adopted Langmuir Blodgett (LB) technique to fabricate pressure sensitive molecular films (PSMFs) using Pd (Ⅱ) Octaethylporphine (PdOEP) and Pd (Ⅱ) Mesoporphyrin IX (PdMP), and have tested these PSMFs to evaluate the feasibility of the pressure measurement around micro-devices. It is clarified that the PSMF composed of PdMP has higher sensitively than that of PdOEP. Since it is also considered that the sensitivity of PSMFs can be increased by introducing arachidic acid as the spacer molecules to prevent the aggregation of luminescent molecules, we have produced PSMFs with several molar ratio of PdMP to arachidic acid. At the most suitable ratio, the PSMF has sufficient sensitivity in the low pressure region with high Knudsen number, even if the amount of the luminescent molecules in the PSMF layer is smaller than those in conventional PSPs. This indicates that the PSMF is feasible to measure the pressure in high Knudsen number flows such as micro-flows. | |||||
言語 | en | |||||
出版者 | ||||||
出版者 | 日本機械学会 | |||||
言語 | ja | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0387-5016 | |||||
書誌情報 |
ja : 日本機械学會論文集 B編 巻 72, 号 718, p. 1475-1482, 発行日 2006-06 |
|||||
フォーマット | ||||||
値 | application/pdf | |||||
著者版フラグ | ||||||
値 | publisher | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2237/9015 | |||||
識別子タイプ | HDL |